Voltammetric Behaviour and Determination of 8-Hydroxyquinoline Using a Glassy Carbon Paste Electrode and the Theoretical Study of its Electrochemical Oxidation Mechanism

被引:1
作者
Stevic, Milica C. [1 ]
Ignjatovic, Ljubisa M. [1 ]
Ciric-Marjanovic, Gordana [1 ]
Stanisic, Svetlana M. [1 ]
Stankovic, Dalibor M. [2 ]
Zima, Jiri [3 ]
机构
[1] Univ Belgrade, Fac Phys Chem, Belgrade 11158, Serbia
[2] Univ Belgrade, Fac Chem, Belgrade 11158, Serbia
[3] Charles Univ Prague, UNESCO Lab Environm Electrochem, Dept Analyt Chem, CZ-12843 Prague 2, Czech Republic
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2011年 / 6卷 / 07期
关键词
8-Hydroxyquinoline; Glassy Carbon Paste Electrode; Cyclic Voltammetry; Differential Pulse Voltammetry; Computational method; POLYMERIZATION; DERIVATIVES; COMPLEXES; TOXICITY; COPPER; WATER; AM1;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The 8-Hydroxyquinoline (8HQ) oxidation process has been investigated by Cyclic Voltammetry using a Glassy Carbon Paste Electrode (GCPE) as a working electrode. The theoretical study of the mechanism of electrochemical oxidation of 8HQ has been based on the AM1 semi-empirical quantum chemical computations of the heats of formation of the reaction intermediates, taking into account the influence of pH and solvation effects. We proposed that a two-electron irreversible process, controlled by diffusion of electroactive species, is responsible for an oxidation peak of 8HQ that appears in all cyclic voltammograms recorded on a clean electrode in the solutions of pH in the range 2-12 with a supporting electrolyte of Britton-Robinson Buffer/methanol. A single-electron oxidation of 8HQ leads, depending on pH, to the formation of various free radical species that combine to make dimers which, after being oxidized once more, give quinonoid-type compounds. Recording continuous cyclic voltammograms on the GCPE, pre-peaks appear as a consequence of dimer and quinonoid compounds formation. By applying Differential Pulse Voltammetry for 8HQ determination it was calculated that the limit of detection was 5.2x10(-8) mol/L. For more sensitive quantitative determination of the investigated substance Adsorptive Stripping Differential Pulse Voltammery can be used since it was found that after 300s-deposition time at 0.0 V vs. Saturated Calomel Electrode, a 2.1 times higher peak current than without deposition was obtained.
引用
收藏
页码:2509 / 2525
页数:17
相关论文
共 50 条
  • [1] Electrochemical oxidation of 6-hydroxyquinoline on a glassy carbon paste electrode: Voltammetric and computational study
    Stevic, Milica C.
    Ignjatovic, Ljubisa M.
    Ciric-Marjanovic, Gordana
    Marjanovic, Budimir
    Barek, Jiri
    Zima, Jiri
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 677 : 69 - 77
  • [2] Sensitive Voltammetric Determination of Cadmium(II) with 8-Hydroxyquinoline and Ionic Liquid Modified Carbon Paste Electrode
    Jia, Shaohui
    Gong, Shixing
    Cheng, Yong
    Wang, Huiyun
    Liu, Hejian
    Zhang, Bo
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (11) : 1217 - 1222
  • [3] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [4] The Electrochemical Redox Behaviour of Acid Blue 25 and its Quantitative Measurement at Carbon Paste Electrode: A Voltammetric Study
    Gopal, Palla
    Reddy, Tukiakula Madhusudana
    Raghu, Pamula
    Reddaiah, Kasetty
    Narayana, Palakollu Venkata
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2014, 6 (02): : 183 - 194
  • [5] Study of voltammetric determination of carcinogenic 1-nitropyrene and 1-aminopyrene using a glassy carbon paste electrode
    Barek, J
    Muck, A
    Wang, J
    Zima, J
    SENSORS, 2004, 4 (05) : 47 - 57
  • [6] Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids
    Alghamdi, Ali F.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (03) : 363 - 369
  • [7] Electrochemical Determination of L-dopa in the Presence of Ascorbic Acid by Gold Nanoparticles Functionalized 8-Hydroxyquinoline Modified Glassy Carbon Electrode
    Jayakumar, Chinnappan
    Jeseentharani, Vedhakkani
    Reddy, Yerramala Subba
    Kulandainathan, Manickam Anbu
    Nagaraj, Karachalacheruvu Seetharamaiah
    Jeyaraj, Boniface
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (02): : 193 - 205
  • [8] Electrochemical oxidation of niclosamide at a glassy carbon electrode and its determination by voltammetry
    Alemu, H
    Khoabane, NM
    Tseki, PF
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2003, 17 (01) : 95 - 106
  • [9] Voltammetric determination of imidacloprid insecticide in selected samples using a carbon paste electrode
    Papp, Zsigmond
    Svancara, Ivan
    Guzsvany, Valeria
    Vytras, Karel
    Gaal, Ferenc
    MICROCHIMICA ACTA, 2009, 166 (1-2) : 169 - 175
  • [10] Sensitive Detection of 8-Hydroxyquinoline in Cosmetics by Using a Poly(tannic acid)-Modified Glassy Carbon Electrode
    Gao, Zhimin
    Zeng, Qiang
    Wang, Min
    Wang, Lishi
    CHEMISTRYSELECT, 2022, 7 (16):