An assessment of the quality of optical coherence tomography image acquisition

被引:5
|
作者
Zago, Elder Iarossi [1 ]
Samdani, Abdul Jawwad [1 ]
Pereira, Gabriel Tensol Rodrigues [1 ]
Vergara-Martel, Armando [1 ]
Alaiti, Mohamad Amer [2 ,3 ]
Dallan, Luis Augusto [1 ]
Pizzato, Patricia Ely [1 ]
Zimin, Vladislav [1 ]
Fares, Anas [1 ]
Bezerra, Hiram G. [1 ]
机构
[1] Univ Hosp Cleveland Med Ctr, Harrington Heart & Vasc Inst, Cardiovasc Imaging Core Lab, 11100 Euclid Ave,Lakeside Bldg,Room 3113, Cleveland, OH 44106 USA
[2] Univ Texas Southwestern, Dallas, TX USA
[3] VA North Texas Healthcare Syst, Dallas, TX USA
来源
关键词
Image acquisition; Optical coherence tomography; Intravascular imaging; PERCUTANEOUS CORONARY INTERVENTION; MOLECULAR-WEIGHT DEXTRAN; GUIDE DECISION-MAKING; CLINICAL-APPLICATIONS; DOCUMENT; SAFETY; OPTIMIZATION; FEASIBILITY; TERMINOLOGY; METHODOLOGY;
D O I
10.1007/s10554-020-01795-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optical coherence tomography (OCT) provides excellent image resolution, however OCT optimal acquisition is essential but could be challenging owing to several factors. We sought to assess the quality of OCT pullbacks and identify the causes of suboptimal image acquisition. We evaluated 784 (404 pre-PCI; 380 post-PCI) coronary pullbacks from an anonymized OCT database from our Cardiovascular Imaging Core Laboratory. Imaging of the region-of-interest (ROI-lesion or stented segment plus references) was incomplete in 16.1% pullbacks, caused by pullback starting too proximal (63.7%), inappropriate pullback length (17.1%) and pullback starting too distal (11.4%). The quality of image acquisition was excellent in 36.3% pullbacks; whereas 4% pullbacks were unanalyzable. Pullback quality was most commonly affected by poor blood displacement from inadequate contrast volume (27.4%) or flow (25.6%), followed by artifacts (24.1%). Acquisition mode was 'High-Resolution' (54 mm) in 74.4% and 'Survey' (75 mm) in 25.6% of cases. The 54 mm mode was associated with incomplete ROI imaging (p = 0.020) and inadequate contrast volume (p = 0.035). We observed a substantial frequency of suboptimal image acquisition and identified its causes, most of which can be addressed with minor modifications during the procedure, ultimately improving patient outcomes.
引用
收藏
页码:1013 / 1020
页数:8
相关论文
共 50 条
  • [1] An assessment of the quality of optical coherence tomography image acquisition
    Elder Iarossi Zago
    Abdul Jawwad Samdani
    Gabriel Tensol Rodrigues Pereira
    Armando Vergara-Martel
    Mohamad Amer Alaiti
    Luis Augusto Dallan
    Patricia Ely Pizzato
    Vladislav Zimin
    Anas Fares
    Hiram G. Bezerra
    The International Journal of Cardiovascular Imaging, 2020, 36 : 1013 - 1020
  • [2] An Assessment of the Quality of Optical Coherence Tomography Image Acquisition: Are We Doing the Basics Right?
    Zago, Elder
    Pereira, Gabriel Tensol Rodrigues
    Dallan, Luis Augusto
    Pizzato, Patricia
    Samdani, Jawwad
    Jia, Dean
    Elbey, Mehmet
    Zimin, Vlad
    Vergara-Martel, Armando
    Attizzani, Guilherme
    Bezerra, Hiram
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S2 - S2
  • [3] Rapid radial optical coherence tomography image acquisition
    Lebed, Evgeniy
    Lee, Sieun
    Sarunic, Marinko V.
    Beg, Mirza Faisal
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (03)
  • [4] Toward image quality assessment in optical coherence tomography (OCT) of rat kidney
    Fang, Yuhong
    Gong, Wei
    Li, Junxia
    Li, Weijun
    Tan, Jianmin
    Xie, Shusen
    Huang, Zheng
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 32
  • [5] Local quality assessment for Optical Coherence Tomography
    Barnum, Peter
    Chen, Mei
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Schuman, Joel
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 392 - +
  • [6] Optical coherence tomography angiography image quality assessment at varying retinal expertise levels
    Woetzel, Anne K.
    Lauermann, Jost L.
    Kreitz, Kiana
    Alnawaiseh, Maged
    Clemens, Christoph R.
    Eter, Nicole
    Alten, Florian
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (02): : 161 - 167
  • [7] Intracoronary optical coherence tomography, basic theory and image acquisition techniques
    F. Prati
    M. W. Jenkins
    A. Di Giorgio
    A. M. Rollins
    The International Journal of Cardiovascular Imaging, 2011, 27 : 251 - 258
  • [8] Comparing the assessment of image quality of Optical Coherence Tomography data with Deep Neural Networks and Image processing
    Patel, Krunalkumar Ramanbhai
    Ranipa, Keyur
    Shivaram, Namritha
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [9] Intracoronary optical coherence tomography, basic theory and image acquisition techniques
    Prati, F.
    Jenkins, M. W.
    Di Giorgio, A.
    Rollins, A. M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (02): : 251 - 258
  • [10] A new quality assessment parameter for optical coherence tomography
    Stein, DM
    Ishikawa, H
    Hariprasad, R
    Wollstein, G
    Noecker, RJ
    Fujimoto, JG
    Schuman, JS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (02) : 186 - 190