Development and characterization of ion-exchange polymer blend membranes

被引:155
作者
Cui, W [1 ]
Kerres, J [1 ]
Eigenberger, G [1 ]
机构
[1] Univ Stuttgart, Inst Chem Verfahrenstech, D-70199 Stuttgart, Germany
关键词
D O I
10.1016/S1383-5866(98)00069-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the presented paper, the preparation and characterization of new ionomer blend membranes containing sulfonated poly (etheretherketone) PEEK Victrex(R) is described. The second blend components were Polysulfone Udel(R)-ortho-sulfone-diamine, polymide PA Trogamid P (producer: Hills) and poly(etherimide) PEI Ultem (producer: General Electric). In the blend membranes swelling was reduced by specific interaction, in the case of the blend components PA and PEI hydrogen bonds, and in the case of the blend component PSU-NH2 (partial) polysalt formation, leading to electrostatic interaction between the blend component macromolecules, and hydrogen bonds. The acid-base interactions also led to decrease of ionic conductivity by partial blocking of SO3- groups for cation transport, compared with the ionic conductivity of the hydrogen bond blends. The acid-base blends showed better ion permselectivities than the hydrogen bond blends, even at high electrolyte concentrations, and thus better performance in electrodialysis. The thermal stability of the investigated blends was very good and in the case of the acid-base blends even better than the thermal stability of pure PEEK-SO3H. DSC traces of the blend membranes showed only one T-g. In addition, the membranes are transparent to visible light. But therefrom it cannot be concluded that the blend components are miscible to the molecular level: at the acid-base blends, the T-g of PEEK-SO3H is very similar to the T-g of PSU-NH2, and in the investigated hydrogen bond blends, the portion of PA or PEI, respectively, might be too low to be detected by DSC. The investigated blend membranes showed similar performance as the commercial cation-exchange membrane CMX in electrodialysis (ED) application. The performance of the acid-base blend membrane is better than the performance of the hydrogen bonded PEEK-PA blend, especially in the ED experiment applying the higher NaCl concentration. This is mainly due to the lower swelling and thus better ion permselectivity of the acid-base blend membrane, compared with the PEEK-PA blend. To get a deeper insight into the microphase structure of the investigated blends, dynamic mechanical analyses and TEM investigations of the prepared blend membranes are planned. In addition, due to their promising properties, the preparation of arylene main-chain acid-base blends with other polymeric acidic and basic components is planned. Furthermore, the acid-base blend membranes will be tested in H-2 polymer electrolyte fuel cells and direct methanol fuel cells, because preliminary tests have shown that they have a good perspective in this application (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:145 / 154
页数:10
相关论文
共 11 条
  • [1] BLENDS OF RIGID-ROD AND FLEXIBLE MACROMOLECULES
    EISENBACH, CD
    HOFMANN, J
    FISCHER, K
    [J]. MACROMOLECULAR RAPID COMMUNICATIONS, 1994, 15 (02) : 117 - 124
  • [2] EISENBACH CD, 1995, ACS POLYM PREPR DIV, V36, P795
  • [3] ELVERS B, 1992, ULLMANNS ENCY IND A, V21
  • [4] CHEMICAL MODIFICATION OF POLYSULFONES .2. AN EFFICIENT METHOD FOR INTRODUCING PRIMARY AMINE GROUPS ONTO THE AROMATIC CHAIN
    GUIVER, MD
    ROBERTSON, GP
    FOLEY, S
    [J]. MACROMOLECULES, 1995, 28 (23) : 7612 - 7621
  • [5] HELMERMETZMANN F, 1993, Patent No. 0574791
  • [6] KATIME IA, 1996, POLYM MAT ENCY, V5, P3097
  • [7] KERRES J, UNPUB J POLYM SCI PC
  • [8] KUSOMOTO K, 1976, POLYM J, V8, P225
  • [9] MCRAE WA, 1960, Patent No. 2962454
  • [10] PARTIALLY SULFONATED POLY(ARYLENE ETHER SULFONE) - A VERSATILE PROTON CONDUCTING MEMBRANE MATERIAL FOR MODERN ENERGY-CONVERSION TECHNOLOGIES
    NOLTE, R
    LEDJEFF, K
    BAUER, M
    MULHAUPT, R
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1993, 83 (02) : 211 - 220