The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study

被引:74
|
作者
Amornvit, Pokpong [1 ]
Sanohkan, Sasiwimol [1 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai 90110, Songkhla, Thailand
关键词
digital; face scanners; accuracy; three-dimensional analysis; face analysis; facial driven design; INTRAORAL SCANNERS; FACIAL ASYMMETRY; ARCH IMPRESSIONS; RELIABILITY; TECHNOLOGY; WORKFLOW; 2D;
D O I
10.3390/ijerph16245061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Face scanners promise wide applications in medicine and dentistry, including facial recognition, capturing facial emotions, facial cosmetic planning and surgery, and maxillofacial rehabilitation. Higher accuracy improves the quality of the data recorded from the face scanner, which ultimately, will improve the outcome. Although there are various face scanners available on the market, there is no evidence of a suitable face scanner for practical applications. The aim of this in vitro study was to analyze the face scans obtained from four scanners; EinScan Pro (EP), EinScan Pro 2X Plus (EP+) (Shining 3D Tech. Co., Ltd. Hangzhou, China), iPhone X (IPX) (Apple Store, Cupertino, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA), and to compare scans obtained from various scanners with the control (measured from Vernier caliper). This should help to identify the appropriate scanner for face scanning. A master face model was created and printed from polylactic acid using the resolution of 200 microns on x, y, and z axes and designed in Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The face models were 3D scanned with four scanners, five times, according to the manufacturer's recommendations; EinScan Pro (Shining 3D Tech. Co., Ltd. Hangzhou, China), EinScan Pro 2X Plus (Shining 3D Tech. Co., Ltd. Hangzhou, China) using Shining Software, iPhone X (Apple Store, Cupertino, CA, USA) using Bellus3D Face Application (Bellus3D, version 1.6.2, Bellus3D, Inc. Campbell, CA, USA), and Planmeca ProMax 3D Mid (PM) (Planmeca USA, Inc. IL, USA). Scan data files were saved as stereolithography (STL) files for the measurements. From the STL files, digital face models are created in the computer using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). Various measurements were measured five times from the reference points in three axes (x, y, and z) using a digital Vernier caliper (VC) (Mitutoyo 150 mm Digital Caliper, Mitutoyo Co., Kanagawa, Japan), and the mean was calculated, which was used as the control. Measurements were measured on the digital face models of EP, EP+, IPX, and PM using Rhinoceros 3D modeling software (Rhino, Robert McNeel and Associates for Windows, Washington DC, USA). The descriptive statistics were done from SPSS version 20 (IBM Company, Chicago, USA). One-way ANOVA with post hoc using Scheffe was done to analyze the differences between the control and the scans (EP, EP+, IPX, and PM). The significance level was set at p = 0.05. EP+ showed the highest accuracy. EP showed medium accuracy and some lesser accuracy (accurate until 10 mm of length), but IPX and PM showed the least accuracy. EP+ showed accuracy in measuring the 2 mm of depth (diameter 6 mm). All other scanners (EP, IPX, and PM) showed less accuracy in measuring depth. Finally, the accuracy of an optical scan is dependent on the technology used by each scanner. It is recommended to use EP+ for face scanning.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Accuracy of four intraoral scanners in oral implantology: a comparative in vitro study
    Mario Imburgia
    Silvia Logozzo
    Uli Hauschild
    Giovanni Veronesi
    Carlo Mangano
    Francesco Guido Mangano
    BMC Oral Health, 17
  • [32] Influence of the angles and number of scans on the accuracy of 3D laser scanning
    Lee, Kyung-Min
    Song, Hyo-Young
    Lee, Ki-Heon
    Hwang, Hyeon-Shik
    KOREAN JOURNAL OF ORTHODONTICS, 2011, 41 (02) : 76 - 86
  • [33] Accuracy Analysis of Digital Models from Intraoral Scanners and 3D-Printed Casts in Children and Teenagers
    Serrano-Velasco, Diego
    Martin-Vacas, Andrea
    Giovannini, Giovanni
    Paz-Cortes, Marta Macarena
    Aragoneses, Juan Manuel
    CHILDREN-BASEL, 2024, 11 (09):
  • [34] Investigation of the effects of arch size and implant angulation on the accuracy of digital impression using two intraoral scanners: An in vitro study
    Geramipanah, Farideh
    Sadighpour, Leyla
    Payaminia, Leila
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2023, 9 (06): : 983 - 992
  • [35] Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners
    Mack, Spencer
    Bonilla, Tammy
    English, Jeryl D.
    Cozad, Benjamin
    Akyalcin, Sercan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 152 (03) : 420 - 425
  • [36] Evaluating the accuracy of hand models obtained from two 3D scanning techniques
    Yu, Fang
    Zeng, Lei
    Pan, Ding
    Sui, Xinlei
    Tang, Juyu
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [37] Accuracy of 6 Desktop 3D Printers in Dentistry: A Comparative In Vitro Study
    Mangano, Francesco G.
    Admakin, Oleg
    Bonacina, Matteo
    Biaggini, Francesco
    Farronato, Davide
    Lerner, Henriette
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2020, 28 (02) : 75 - 85
  • [38] Accuracy of conventional impressions and digital scans for implant-supported fixed prostheses in maxillary free-ended partial edentulism: An in vitro study
    El Osta, Nada
    Drancourt, Noemie
    Auduc, Chantal
    Veyrune, Jean-Luc
    Nicolas, Emmanuel
    JOURNAL OF DENTISTRY, 2024, 143
  • [39] In vitro study of the accuracy and efficiency of wireless intraoral scanners at various battery levels
    Sombun, Santisuk
    Ongthiemsak, Chakree
    JOURNAL OF DENTISTRY, 2023, 138
  • [40] Full arch accuracy of intraoral scanners with different acquisition technologies: An in vitro study
    Baresel, Ingo
    Baresel, Jens
    JOURNAL OF DENTISTRY, 2025, 156