On the closing sounds of a mechanical heart valve

被引:14
|
作者
Wu, CF
Herman, BA
Retta, SM
Grossman, LW
Liu, JS
Hwang, NHC
机构
[1] Florida Atlantic Univ, Coll Engn, Ctr Appl Stochast Res, Boca Raton, FL 33431 USA
[2] US FDA, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Rockville, MD 20852 USA
[3] Natl Hlth Res Inst, Div Med Engn Res, Miaoli, Taiwan
基金
美国国家科学基金会;
关键词
mechanical heart valves; cavitation detection; cavitation noise; impact sound;
D O I
10.1007/s10439-005-3237-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In the 1994 Replacement Heart Valve Guidance of the U.S. Food and Drug Administration (FDA), in-vitro testing is required to evaluate the potential for cavitation damage of a mechanical heart valve (MHV). To fulfill this requirement, the stroboscopic high-speed imaging method is commonly used to visualize cavitation bubbles at the instant of valve closure. The procedure is expensive; it is also limited because not every cavitation event is detected, thus leaving the possibility of missing the whole cavitation process. As an alternative, some researchers have suggested an acoustic cavitation-detection method, based on the observation that cavitation noise has a broadband spectrum. In practice, however, it is difficult to differentiate between cavitation noise and the valve closing sound, which may also contain high-frequency components. In the present study, the frequency characteristics of the closing sound in air of a Bjork-Shiley Convexo-Concave (BSCC) valve are investigated. The occluder closing speed is used as a control parameter, which is measured via a laser sweeping technique. It is found that for the BSCC valve tested, the distribution of the sound energy over its frequency domain changes at different valve closing speeds, but the cut-off frequency remains unchanged at 123.32 +/- 6.12 kHz. The resonant frequencies of the occluder are also identified from the valve closing sound.
引用
收藏
页码:743 / 750
页数:8
相关论文
共 50 条
  • [1] On the Closing Sounds of a Mechanical Heart Valve
    Changfu Wu
    Bruce A. Herman
    Stephen M. Retta
    Laurence W. Grossman
    Jia-Shing Liu
    Ned H. C. Hwang
    Annals of Biomedical Engineering, 2005, 33 : 743 - 750
  • [2] Acoustical analysis of mechanical heart valve sounds for early detection of malfunction
    Famaey, Nele
    Defever, Korijn
    Bielen, Paul
    Flameng, Willem
    Sloten, Jos Vander
    Sas, Paul
    Meuris, Bart
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (08) : 934 - 939
  • [3] Mechanical heart valve cavitation
    Johansen, P
    EXPERT REVIEW OF MEDICAL DEVICES, 2004, 1 (01) : 95 - 104
  • [4] Developments in mechanical heart valve prosthesis
    Kalyani Nair
    C. V. Muraleedharan
    G. S. Bhuvaneshwar
    Sadhana, 2003, 28 : 575 - 587
  • [5] The Apex bileaflet mechanical heart valve
    Mohammadi H.
    Bhullar A.
    Journal of Medical Engineering and Technology, 2021, 45 (01) : 41 - 51
  • [6] Developments in mechanical heart valve prosthesis
    Nair, K
    Muraleedharan, CV
    Bhuvaneshwar, GS
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2003, 28 (3-4): : 575 - 587
  • [7] CAVITATION POTENTIAL OF MECHANICAL HEART-VALVE PROSTHESES
    GRAF, T
    FISCHER, H
    REUL, H
    RAU, G
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (03) : 169 - 174
  • [8] Role of vortices in growth of microbubbles at mitral mechanical heart valve closure
    Rambod, Edmond
    Beizai, Masoud
    Sahn, David J.
    Gharib, Morteza
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (07) : 1131 - 1145
  • [9] Role of Vortices in Growth of Microbubbles at Mitral Mechanical Heart Valve Closure
    Edmond Rambod
    Masoud Beizai
    David J. Sahn
    Morteza Gharib
    Annals of Biomedical Engineering, 2007, 35 : 1131 - 1145
  • [10] INVITRO PULSATILE FLOW HEMODYNAMICS OF 5 MECHANICAL AORTIC HEART-VALVE PROSTHESES
    WALKER, PG
    YOGANATHAN, AP
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 : S113 - S123