Electrogenerated Chemiluminescence Biosensing

被引:307
作者
Qi, Honglan [1 ]
Zhang, Chengxiao [1 ]
机构
[1] Shaanxi Normal Univ, Key Lab Analyt Chem Life Sci Shaanxi Prov, Sch Chem & Chem Engn, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
SELF-ENHANCED ELECTROCHEMILUMINESCENCE; HYBRIDIZATION CHAIN-REACTION; QUANTUM DOTS; LUMINESCENCE; AMPLIFICATION; PROTEIN; ARRAY; PROBE; ELECTROCHEMISTRY; IMMUNOASSAYS;
D O I
10.1021/acs.analchem.9b03425
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This Feature simply introduces the history and mechanism of classical electrogenerated chemiluminescence (ECL) systems for the detection of biomolecules, highlights new advances and emerging fields of the ECL biosensing with recent illustrative examples, and presents the challenges and perspectives of ECL biosensing. © 2019 American Chemical Society.
引用
收藏
页码:524 / 534
页数:11
相关论文
共 74 条
[41]   Homogenous electrogenerated chemiluminescence immunoassay for human immunoglobulin G using N-(aminobutyl)-N-ethylisoluminol as luminescence label at gold nanoparticles modified paraffin-impregnated graphite electrode [J].
Qi, Honglan ;
Zhang, Yi ;
Peng, Yage ;
Zhang, Chengxiao .
TALANTA, 2008, 75 (03) :684-690
[42]   Electrogenerated Chemiluminescence Peptide-Based Biosensor for the Determination of Prostate-Specific Antigen Based on Target-Induced Cleavage of Peptide [J].
Qi, Honglan ;
Li, Min ;
Dong, Manman ;
Ruan, Sanpeng ;
Gao, Qiang ;
Zhang, Chengxiao .
ANALYTICAL CHEMISTRY, 2014, 86 (03) :1372-1379
[43]   Ultrasensitive Electrogenerated Chemiluminescence Peptide-Based Method for the Determination of Cardiac Troponin I Incorporating Amplification of Signal Reagent-Encapsulated Liposomes [J].
Qi, Honglan ;
Qiu, Xiaoying ;
Xie, Danping ;
Ling, Chen ;
Gao, Qiang ;
Zhang, Chengxiao .
ANALYTICAL CHEMISTRY, 2013, 85 (08) :3886-3894
[44]   Applications of Nanomaterials in Electrogenerated Chemiluminescence Biosensors [J].
Qi, Honglan ;
Peng, Yage ;
Gao, Qiang ;
Zhang, Chengxiao .
SENSORS, 2009, 9 (01) :674-695
[45]   Electrochemiluminescence (ECL) [J].
Richter, MM .
CHEMICAL REVIEWS, 2004, 104 (06) :3003-3036
[46]   CHEMILUMINESCENCE OF ELECTROGENERATED 9,10-DIPHENYLANTHRACENE ANION RADICAL [J].
SANTHANA.KS ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1965, 87 (01) :139-&
[47]   Assembling of Sulfur Quantum Dots in Fission of Sublimed Sulfur [J].
Shen, Lihua ;
Wang, Hongni ;
Liu, Shengnan ;
Bai, Zhuangwei ;
Zhang, Sichun ;
Zhang, Xinrong ;
Zhang, Chengxiao .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2018, 140 (25) :7878-7884
[48]   Double Covalent Coupling Method for the Fabrication of Highly Sensitive and Reusable Electrogenerated Chemiluminescence Sensors [J].
Sun, Bo ;
Qi, Honglan ;
Ma, Fen ;
Gao, Qiang ;
Zhang, Chengxiao ;
Miao, Wujian .
ANALYTICAL CHEMISTRY, 2010, 82 (12) :5046-5052
[49]  
Suomi J, 2011, REV FLUORESC, V6, P47, DOI 10.1007/978-1-4419-9672-5_3
[50]   Self-Enhanced Electrochemiluminescence of an Iridium(III) Complex: Mechanistic Insight [J].
Swanick, Kalen N. ;
Ladouceur, Sebastien ;
Zysman-Colman, Eli ;
Ding, Zhifeng .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (44) :11079-11082