Analysis of undigested honey samples by isotope dilution inductively coupled plasma mass spectrometry with direct injection nebulization (ID-ICP-MS)

被引:18
|
作者
Packer, AP [1 ]
Giné, MF [1 ]
机构
[1] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
direct honey analysis; multielement determination; direct injection nebulizer; isotope dilution; inductively coupled plasma mass spectrometry;
D O I
10.1016/S0584-8547(00)00294-9
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Undigested honey samples were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) using direct injection nebulization (DIN). Samples were diluted 25-fold using dilute HNO3 to which Triton X-100 was added. Isotope dilution (ID) was used to quantify Ba, Cu, ph and Zn in these natural matrix samples. DIN parameters were optimized to obtain a stable transient signal enough to determine multiple isotope ratios. The Ba, Cu and Zn isotope ratios were measured in a single sample injection of 50 mul diluted honey and the Pb isotopes in a separate injection. The analysis was characterized by precisions given by R.S.D. values from 0.20 to 1.24% for Ba, 0.49-1.23% for Cu, 0.61-2.28% for Pb and 0.50-1.51% for Zn. The results were in agreement, at the 95% confidence level, with those obtained by analyzing digested samples using external calibration. Using this direct method, 30 real honey samples per hour could be analyzed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [21] ONLINE STANDARD ADDITIONS WITH DIRECT INJECTION NEBULIZATION FOR INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    WIEDERIN, DR
    SMYCZEK, RE
    HOUK, RS
    ANALYTICAL CHEMISTRY, 1991, 63 (15) : 1626 - 1631
  • [22] INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH DIRECT INJECTION NEBULIZATION FOR MERCURY ANALYSIS OF DRINKING-WATER
    POWELL, MJ
    QUAN, ESK
    BOOMER, DW
    WIEDERIN, DR
    ANALYTICAL CHEMISTRY, 1992, 64 (19) : 2253 - 2257
  • [23] Determination of trace amounts of zinc in water samples by flow injection isotope dilution inductively coupled plasma mass spectrometry
    Hwang, TJ
    Jiang, SJ
    ANALYST, 1997, 122 (03) : 233 - 237
  • [24] Protocol for isotope dilution using inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of inorganic elements
    Watters, RL
    Eberhardt, KR
    Beary, ES
    Fassett, JD
    METROLOGIA, 1997, 34 (01) : 87 - 96
  • [25] Determination of chloride in crude oils by direct dilution using inductively coupled plasma tandem mass spectrometry (ICP-MS/MS)
    Nelson, Jenny
    Poirier, Laura
    Lopez-Linares, Francisco
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (07) : 1433 - 1438
  • [26] Iodine determination in food samples using inductively coupled plasma isotope dilution mass spectrometry
    Rädlinger, G
    Heumann, KG
    ANALYTICAL CHEMISTRY, 1998, 70 (11) : 2221 - 2224
  • [27] Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation
    Bendahl, L
    Gammelgaard, B
    Jons, O
    Farver, O
    Hansen, SH
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (01) : 38 - 42
  • [28] Isotope ratio measurement of uranium in safeguards environmental samples by inductively-coupled plasma mass spectrometry (ICP-MS)
    Magara, M
    Sakakibara, T
    Kurosawa, S
    Takahashi, M
    Sakurai, S
    Hanzawa, Y
    Esaka, F
    Watanabe, K
    Usuda, SE
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2002, 39 (04) : 308 - 311
  • [29] Boron isotope ratios in plants enriched in 10B as determined by direct injection nebulization inductively coupled plasma mass spectrometry
    Bellato, ACS
    Menegário, AA
    Giné, MF
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2001, 32 (11-12) : 1981 - 1990
  • [30] Direct determination of mercury in cosmetic samples by isotope dilution inductively coupled plasma mass spectrometry after dissolution with formic acid
    Gao, Ying
    Shi, Zeming
    Zong, Qinxia
    Wu, Peng
    Su, Jing
    Liu, Rui
    ANALYTICA CHIMICA ACTA, 2014, 812 : 6 - 11