共 50 条
Computed tomography-based validation of abdominal adiposity measurements from ultrasonography, dual-energy X-ray absorptiometry and anthropometry
被引:81
|作者:
Gradmark, Anna M. I.
[1
]
Rydh, Anders
[2
]
Renstrom, Frida
[1
]
De Lucia-Rolfe, Emanuella
[3
]
Sleigh, Alison
[4
]
Nordstrom, Peter
[5
]
Brage, Soren
[3
]
Franks, Paul W.
[1
]
机构:
[1] Umea Univ Hosp, Div Med, Dept Publ Hlth & Clin Med, Genet Epidemiol & Clin Res Grp, S-90187 Umea, Sweden
[2] Umea Univ Hosp, Dept Radiol, S-90185 Umea, Sweden
[3] Inst Metab Sci, MRC Epidemiol Unit, Cambridge, England
[4] Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge, England
[5] Umea Univ Hosp, Dept Surg & Perioperat Sci, S-90185 Umea, Sweden
关键词:
Computed tomography;
Ultrasound;
Waist circumference;
Waist:height ratio;
Dual-energy X-ray absorptiometry;
Obesity;
Adipose tissue;
Validation;
VISCERAL FAT;
INSULIN-RESISTANCE;
INTRAABDOMINAL FAT;
BODY-FAT;
TISSUE;
OBESITY;
WOMEN;
VALIDITY;
ADULTS;
D O I:
10.1017/S0007114510000796
中图分类号:
R15 [营养卫生、食品卫生];
TS201 [基础科学];
学科分类号:
100403 ;
摘要:
Large-scale aetiological studies of obesity and its pathological consequences require accurate measurements of adipose mass, distribution and subtype. Here, we compared the validity of three abdominal obesity assessment methods (dual-energy X-ray absorptiometry (DXA), ultrasound and anthropometry) against the gold-standard method of computed tomography (CT) in twenty-nine non-diseased middle-aged men (BMI 26.5 (SD 3.1) kg/m(2)) and women (BMI 25.5 (SD 3.2) kg/m(2)). Assessments of adipose mass (kg) and distribution (total subcutaneous (TSAT), superficial subcutaneous (SSAT), deep subcutaneous (DSAT) and visceral (VAT)) were obtained. Spearman's correlations were performed adjusted for age and sex. VAT area that was assessed using ultrasound (r 0.79; P < 0.0001) and waist circumference (r 0.85; P < 0.0001) correlated highly with VAT from CT, as did BMI (r 0.67; P < 0.0001) and DXA (r 0.70; P < 0.0001). DXA (r 0.72; P = 0.0004), BMI (r 0.71; P = 0.0003), waist circumference (r 0.86; P < 0.0001) and ultrasound (r 0.52; P = 0.015) were less strongly correlated with CT TSAT. None of the comparison measures of DSAT was strongly correlated with CT DSAT (all r approximately 0.50; P < 0.02). BMI (r 0.76; P < 0.0001), waist circumference (r 0.65; P = 0.002) and DXA (r 0.75; P < 0.0001) were all fairly strongly correlated with the CT measure of SSAT, whereas ultrasound yielded a weaker yet statistically significant correlation (r 0.48; P = 0.03). Compared with CT, visceral and subcutaneous adiposity can be assessed with reasonable validity using waist circumference and BMI, respectively. Ultrasound or DXA does not generally provide substantially better measures of these traits. Highly valid assessments of DSAT do not appear to be possible with surrogate measures. These findings may help guide the selection of measures for epidemiological studies of obesity.
引用
收藏
页码:582 / 588
页数:7
相关论文