Computed tomography-based validation of abdominal adiposity measurements from ultrasonography, dual-energy X-ray absorptiometry and anthropometry

被引:81
|
作者
Gradmark, Anna M. I. [1 ]
Rydh, Anders [2 ]
Renstrom, Frida [1 ]
De Lucia-Rolfe, Emanuella [3 ]
Sleigh, Alison [4 ]
Nordstrom, Peter [5 ]
Brage, Soren [3 ]
Franks, Paul W. [1 ]
机构
[1] Umea Univ Hosp, Div Med, Dept Publ Hlth & Clin Med, Genet Epidemiol & Clin Res Grp, S-90187 Umea, Sweden
[2] Umea Univ Hosp, Dept Radiol, S-90185 Umea, Sweden
[3] Inst Metab Sci, MRC Epidemiol Unit, Cambridge, England
[4] Addenbrookes Hosp, Wolfson Brain Imaging Ctr, Cambridge, England
[5] Umea Univ Hosp, Dept Surg & Perioperat Sci, S-90185 Umea, Sweden
关键词
Computed tomography; Ultrasound; Waist circumference; Waist:height ratio; Dual-energy X-ray absorptiometry; Obesity; Adipose tissue; Validation; VISCERAL FAT; INSULIN-RESISTANCE; INTRAABDOMINAL FAT; BODY-FAT; TISSUE; OBESITY; WOMEN; VALIDITY; ADULTS;
D O I
10.1017/S0007114510000796
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Large-scale aetiological studies of obesity and its pathological consequences require accurate measurements of adipose mass, distribution and subtype. Here, we compared the validity of three abdominal obesity assessment methods (dual-energy X-ray absorptiometry (DXA), ultrasound and anthropometry) against the gold-standard method of computed tomography (CT) in twenty-nine non-diseased middle-aged men (BMI 26.5 (SD 3.1) kg/m(2)) and women (BMI 25.5 (SD 3.2) kg/m(2)). Assessments of adipose mass (kg) and distribution (total subcutaneous (TSAT), superficial subcutaneous (SSAT), deep subcutaneous (DSAT) and visceral (VAT)) were obtained. Spearman's correlations were performed adjusted for age and sex. VAT area that was assessed using ultrasound (r 0.79; P < 0.0001) and waist circumference (r 0.85; P < 0.0001) correlated highly with VAT from CT, as did BMI (r 0.67; P < 0.0001) and DXA (r 0.70; P < 0.0001). DXA (r 0.72; P = 0.0004), BMI (r 0.71; P = 0.0003), waist circumference (r 0.86; P < 0.0001) and ultrasound (r 0.52; P = 0.015) were less strongly correlated with CT TSAT. None of the comparison measures of DSAT was strongly correlated with CT DSAT (all r approximately 0.50; P < 0.02). BMI (r 0.76; P < 0.0001), waist circumference (r 0.65; P = 0.002) and DXA (r 0.75; P < 0.0001) were all fairly strongly correlated with the CT measure of SSAT, whereas ultrasound yielded a weaker yet statistically significant correlation (r 0.48; P = 0.03). Compared with CT, visceral and subcutaneous adiposity can be assessed with reasonable validity using waist circumference and BMI, respectively. Ultrasound or DXA does not generally provide substantially better measures of these traits. Highly valid assessments of DSAT do not appear to be possible with surrogate measures. These findings may help guide the selection of measures for epidemiological studies of obesity.
引用
收藏
页码:582 / 588
页数:7
相关论文
共 50 条
  • [21] Dual-energy X-ray absorptiometry prediction of adipose tissue depots in children and adolescents
    Bauer, Jacqueline
    Thornton, John
    Heymsfield, Steven
    Kelly, Kim
    Ramirez, Alexander
    Gidwani, Sonia
    Gallagher, Dympna
    PEDIATRIC RESEARCH, 2012, 72 (04) : 420 - 425
  • [22] Measurement of abdominal fat by magnetic resonance imaging, dual-energy X-ray absorptiometry and anthropometry in non-obese men and women
    Kamel, EG
    McNeill, G
    Han, TS
    Smith, FW
    Avenell, A
    Davidson, L
    Tothill, P
    INTERNATIONAL JOURNAL OF OBESITY, 1999, 23 (07) : 686 - 692
  • [23] PRECISION AND STABILITY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS
    JOHNSON, J
    DAWSONHUGHES, B
    CALCIFIED TISSUE INTERNATIONAL, 1991, 49 (03) : 174 - 178
  • [24] USE OF DUAL-ENERGY X-RAY ABSORPTIOMETRY IN OBESE INDIVIDUALS
    TATARANNI, PA
    RAVUSSIN, E
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1995, 62 (04) : 730 - 734
  • [25] Abdominal Fat from Spine Dual-Energy X-Ray Absorptiometry and Risk for Subsequent Diabetes
    Leslie, William D.
    Ludwig, Sora M.
    Morin, Suzanne
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2010, 95 (07) : 3272 - 3276
  • [26] Sarcopenia in liver cirrhosis: the role of computed tomography scan for the assessment of muscle mass compared with dual-energy X-ray absorptiometry and anthropometry
    Giusto, Michela
    Lattanzi, Barbara
    Albanese, Carlina
    Galtieri, Alessia
    Farcomeni, Alessio
    Giannelli, Valerio
    Lucidi, Cristina
    Di Martino, Michele
    Catalano, Carlo
    Merli, Manuela
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2015, 27 (03) : 328 - 334
  • [27] Quantitative assessment of volumetric muscle loss: Dual-energy X-ray absorptiometry and ultrasonography
    Minetto, Marco Alessandro
    Busso, Chiara
    Gamerro, Giulia
    Lalli, Piera
    Massazza, Giuseppe
    Invernizzi, Marco
    CURRENT OPINION IN PHARMACOLOGY, 2021, 57 : 148 - 156
  • [28] Validation of Dual Energy X-Ray Absorptiometry Measures of Abdominal Fat by Comparison with Magnetic Resonance Imaging in an Indian Population
    Taylor, Amy E.
    Kuper, Hannah
    Varma, Ravi D.
    Wells, Jonathan C.
    Bell, Jimmy D.
    Radhakrishna, K. V.
    Kulkarni, Bharati
    Kinra, Sanjay
    Timpson, Nicholas J.
    Ebrahim, Shah
    Smith, George Davey
    Ben-Shlomo, Yoav
    PLOS ONE, 2012, 7 (12):
  • [29] Validation of dual-energy X-ray absorptiometry in live white leghorns
    Schreiweis, MA
    Orban, JI
    Ledur, MC
    Moody, DE
    Hester, PY
    POULTRY SCIENCE, 2005, 84 (01) : 91 - 99
  • [30] Visceral adiposity in persons with chronic spinal cord injury determined by dual energy X-Ray absorptiometry
    Cirnigliaro, Christopher M.
    LaFountaine, Michael F.
    Dengel, Donald R.
    Bosch, Tyler A.
    Emmons, Racine R.
    Kirshblum, Steven C.
    Sauer, Sue
    Asselin, Pierre
    Spungen, Ann M.
    Bauman, William A.
    OBESITY, 2015, 23 (09) : 1811 - 1817