Assessment of liquid desiccant dehumidification aided vapor-compression refrigeration system based on thermo-economic approach

被引:36
作者
Mansuriya, Kiran [1 ]
Patel, Vivek K. [1 ]
Raja, Bansi D. [2 ]
Mudgal, Anurag [1 ]
机构
[1] Pandit Deendayal Petr Univ, Dept Mech Engn, Gandhinagar, Gujarat, India
[2] Indus Univ, Dept Mech Engn, Ahmadabad, Gujarat, India
关键词
Liquid desiccant dehumidification; Total annual cost; Co-efficient of performance; Thermo-economic optimization; AIR-CONDITIONING SYSTEM; MASS-TRANSFER; HEAT-PUMP; THEORETICAL-ANALYSIS; FRESH AIR; OPTIMIZATION; PERFORMANCE; DEHUMIDIFIER/REGENERATOR; LITHIUM;
D O I
10.1016/j.applthermaleng.2019.114542
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents the analysis of a modified liquid desiccant dehumidification incorporated vapour compression refrigeration system based on thermo-economic approach. The thermal model of the proposed system is developed and optimized by considering the co-efficient of performance and the total annual cost of the system as objectives. To focus on the liquid desiccant dehumidification subsystem, seven design variables including thermodynamic and geometric parameters are selected accordingly. The multi-objective optimization results are obtained in the form of Pareto solutions. The effect of dehumidifier height and desiccant to air mass flow rate on the optimized performance of the system is investigated. Further, the effect of design variables on the performance of the system is also examined. The results show that 51.3% of the total cooling load is handled by the desiccant dehumidifier alone. This significant sharing of heat duty by addition of liquid desiccant dehumidification to conventional vapour compression refrigeration system justifies this hybridization for humid and hotter climates. Further investigation at an optimal solution point shows that the co-efficient of performance of the hybrid system is improved up to 68.4% compared to co-efficient of performance of standalone vapour compression refrigeration system for handling the same cooling load. Also, the payback duration of the hybrid system comes out to be 1.54 years.
引用
收藏
页数:13
相关论文
共 52 条
  • [11] Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning
    Dai, YJ
    Wang, RZ
    Zhang, HF
    Yu, JD
    [J]. APPLIED THERMAL ENGINEERING, 2001, 21 (12) : 1185 - 1202
  • [12] Dincer I., 2017, Refrigeration Systems Ad Applications, V3rd
  • [13] Thermodynamic and thermoeconomic analyses of two stage hybrid absorption compression refrigeration system
    Dixit, Manoj
    Arora, Akhilesh
    Kaushik, S. C.
    [J]. APPLIED THERMAL ENGINEERING, 2017, 113 : 120 - 131
  • [14] Exergoeconomic comparison of double effect and combined ejector-double effect absorption refrigeration systems
    Farshi, L. Garousi
    Mahmoudi, S. M. S.
    Rosen, M. A.
    [J]. APPLIED ENERGY, 2013, 103 : 700 - 711
  • [15] Study of an aqueous lithium chloride desiccant system: Air dehumidification and desiccant regeneration
    Fumo, N
    Goswami, DY
    [J]. SOLAR ENERGY, 2002, 72 (04) : 351 - 361
  • [16] Giglio M., EVALUATION HEAT AVAI
  • [17] Optimisation of fin selection and thermal design of counter-current plate-fin heat exchangers
    Guo, Kunpeng
    Zhang, Nan
    Smith, Robin
    [J]. APPLIED THERMAL ENGINEERING, 2015, 78 : 491 - 499
  • [18] Extremely high efficient heat pump with desiccant coated evaporator and condenser
    Hua, L. J.
    Ge, T. S.
    Wang, R. Z.
    [J]. ENERGY, 2019, 170 : 569 - 579
  • [19] Kakac S., 2002, HEAT EXCHANGERS SELE
  • [20] An experimental study on multi-purpose desiccant integrated vapor-compression air-conditioning system
    Khalil, Alsaied