Dual-Energy X-ray Imaging by Simultaneous Integration and Campbelling Readout

被引:0
|
作者
Roessl, Ewald [1 ]
Thran, Axel [1 ]
Martens, Gerhard [1 ]
Istel, Thomas [1 ]
Proksa, Roland [1 ]
Schlomka, Jens-Peter [2 ]
机构
[1] Philips Res Europe Hamburg, Digital Imaging, Rontgenstr 24-26, D-22335 Hamburg, Germany
[2] Philips Res Europe Aachen, X ray Imaging Syst, D-52066 Aachen, Germany
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
dual-energy; computed tomography; Campbell-mode readout; DETECTOR CIRCUITS;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dual-energy imaging is based on the acquisition of two spectrally distinct attenuation measurements. The two most common techniques are the dual-kV technique and the dual-detector layer technique. More recently, another technique was introduced based on the simultaneous acquisition of photon-counting and current integration data (CIX) by means of a dedicated detector readout ASIC. All of the above methods have certain advantages and disadvantages. While depending on the particular realization (e. g., kVp switching, dual-tube systems in computed tomography), the dual-kV technique suffers from a time-lag between the two acquisitions and as a result from susceptibility to motion. The dual-layer technique usually offers less spectral separation and requires a dedicated detection system. The CIX technique suffers from a reduced dynamic range due to the limiting rate performance in the counting channel. In this paper we introduce yet another dual-energy technique, similar to the CIX, however, without the restrictions coming from the limited count rate. We propose dual-energy imaging based on simultaneous acquisition of the mean (DC) and variance (AC) components of the electrical detector signal, i.e., simultaneous integration-mode readout and Campbell-mode readout (fluctuation mode). The method is based on "Campbell's theorem" which states that the variance of the deviations from the mean detector signal is proportional to the second moment of the incoming x-ray energy spectrum. We compare in simulations the dual-energy performance of the proposed new technique with conventional dual-kV and dual-crystal techniques and present first experimental Campbell-mode CT images obtained from a scintillator crystal coupled to a photomultiplier tube. Moreover, we demonstrate the feasibility of separating iodine from calcium with the novel technique and compare it to the separability achieved with a dual-kV technique.
引用
收藏
页码:2112 / 2115
页数:4
相关论文
共 50 条
  • [21] Identification of materials in X-Ray inspections of objects by the dual-energy method
    Osipov, S. P.
    Udod, V. A.
    Wang, Y.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2017, 53 (08) : 568 - 587
  • [22] Rock porosity quantification by dual-energy X-ray computed microtomography
    Teles, A. P.
    Lima, I.
    Topes, R. T.
    MICRON, 2016, 83 : 72 - 78
  • [23] Dual-energy X-ray Imaging in Combination with Automated Threshold Gabor Filtering for Baggage Screening Application
    Behrouz Amir Movafeghi
    Effat Rokrok
    Russian Journal of Nondestructive Testing, 2020, 56 : 765 - 773
  • [24] Dual-energy X-ray Imaging in Combination with Automated Threshold Gabor Filtering for Baggage Screening Application
    Movafeghi, Amir
    Rokrok, Behrouz
    Yahaghi, Effat
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2020, 56 (09) : 765 - 773
  • [25] A curve-based material recognition method in MeV dual-energy X-ray imaging system
    Chen, Zhi-Qiang
    Zhao, Tiao
    Li, Liang
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (01)
  • [26] A curve-based material recognition method in MeV dual-energy X-ray imaging system
    Zhi-Qiang Chen
    Tiao Zhao
    Liang Li
    Nuclear Science and Techniques, 2016, 27 (01) : 173 - 180
  • [27] A curve-based material recognition method in MeV dual-energy X-ray imaging system
    Zhi-Qiang Chen
    Tiao Zhao
    Liang Li
    Nuclear Science and Techniques, 2016, 27
  • [28] Investigation of dual-energy X-ray photon counting using a cadmium telluride detector with dual-energy selection electronics
    Sato, Eiichi
    Kosuge, Yoshiyuki
    Yamanome, Hayato
    Mikata, Aldko
    Miura, Tatsuya
    Oda, Yasuyuki
    Ishii, Tomotaka
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Watanabe, Manabu
    Kusachi, Shinya
    RADIATION PHYSICS AND CHEMISTRY, 2017, 130 : 385 - 390
  • [29] Effective dose reduction in dual-energy flat panel X-ray imaging:: Technique and clinical evaluation
    Avinash, GB
    Jabri, KN
    Uppaluri, R
    Rader, A
    Fischbach, F
    Ricke, J
    Teichgräber, U
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1048 - 1059
  • [30] Dual-Energy Processing of X-ray Images of Beryl in Muscovite Obtained Using Pulsed X-ray Sources
    Komarskiy, Alexander
    Korzhenevskiy, Sergey
    Ponomarev, Andrey
    Chepusov, Alexander
    SENSORS, 2023, 23 (09)