Reliability of measuring facial morphology with a 3-dimensional laser scanning system

被引:168
作者
Kau, CH [1 ]
Richmond, S [1 ]
Zhurov, AI [1 ]
Knox, J [1 ]
Chestnutt, I [1 ]
Hartles, F [1 ]
Playle, R [1 ]
机构
[1] Cardiff Univ, Coll Med, Dept Dental Hlth & Biol Sci, Cardiff CF14 4XY, Wales
关键词
D O I
10.1016/j.ajodo.2004.06.037
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this prospective clinical trial was to evaluate the reliability of a 3-dimensional facial scanning technique for the measurement of facial morphology. Methods: A field study was conducted in 2 comprehensive schools in the South Wales region of the United Kingdom. Forty subjects, mean age 11 years 3 months, were analyzed for soft tissue changes at baseline (T1), within 3 minutes (F2), and 3 days later (M) by using 2 commercially available Minolta Vivid 900 (Osaka, Japan) laser-scanning devices assembled as a stereo pair. Left and right images were merged to form the whole face, and these images were superimposed to assess the errors at T1 and T2, and T1 and T3. Results: The results showed that premerged left and right mean shell deviations were 0.38 +/- 0.14 mm for scans at T1, 0.31 +/- 0.09 mm at T2, and 0.34 +/- 0.12 mm at T3. The mean differences of the merged composite face were 0.31 +/- 0.08 mm between T1 and T2, and 0.40 +/- 0.11 mm between T1 and T3. Paired t tests showed no significant difference between these groups (P > .05). Shell deviation facial maps of the merged scans showed that 90% of the created composite facial scans were within an error of 0.85 mm. Conclusions: Capturing the soft tissue morphology of the face with this technique is clinically reproducible within 3 minutes and 3 days of the initial records.
引用
收藏
页码:424 / 430
页数:7
相关论文
共 32 条
[1]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[2]  
Ayoub A F, 1996, Int J Adult Orthodon Orthognath Surg, V11, P225
[3]   A vision-based three-dimensional capture system for maxillofacial assessment and surgical planning [J].
Ayoub, AF ;
Siebert, P ;
Moos, KF ;
Wray, D ;
Urquhart, C ;
Niblett, TB .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1998, 36 (05) :353-357
[4]   REPRODUCIBILITY OF NATURAL HEAD POSITION [J].
CHIU, CSW ;
CLARK, RKF .
JOURNAL OF DENTISTRY, 1991, 19 (02) :130-131
[5]   A MATHEMATICAL METHOD FOR THE COMPARISON OF 3-DIMENSIONAL CHANGES IN THE FACIAL SURFACE [J].
COOMBES, AM ;
MOSS, JP ;
LINNEY, AD ;
RICHARDS, R ;
JAMES, DR .
EUROPEAN JOURNAL OF ORTHODONTICS, 1991, 13 (02) :95-110
[6]   Laser scanning for the identification of repeatable landmarks of the ears and face [J].
Coward, TJ ;
Watson, RM ;
Scott, BJJ .
BRITISH JOURNAL OF PLASTIC SURGERY, 1997, 50 (05) :308-314
[7]   Facial growth: separating shape from size [J].
Hennessy, RJ ;
Moss, JP .
EUROPEAN JOURNAL OF ORTHODONTICS, 2001, 23 (03) :275-285
[8]   Three-dimensional assessment of the effects of extraction and nonextraction orthodontic treatment on the face [J].
Ismail, SFH ;
Moss, JP ;
Hennessy, R .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 121 (03) :244-256
[9]   Assessment of facial tissue expansion with three-dimensional digitizer scanning [J].
Ji, Y ;
Zhang, F ;
Schwartz, J ;
Stile, F ;
Lineaweaver, WC .
JOURNAL OF CRANIOFACIAL SURGERY, 2002, 13 (05) :687-692
[10]  
Johnston DJ, 2003, CLEFT PALATE-CRAN J, V40, P291, DOI 10.1597/1545-1569(2003)040<0291:AFER>2.0.CO