Comparison Study of Image Performance with Contrast Agent Contents for Brain Magnetic Resonance Imaging

被引:5
作者
Lee, Youngjin [1 ]
Choi, Min Hyeok [1 ]
Goh, Hee Jin [2 ]
Han, Dong-Kyoon [1 ]
机构
[1] Dept Radiol Sci, 553 Sanseong Daero, Songnam, Gyeonggi Do, South Korea
[2] Asan Med Ctr, Dept Radiol, 88 Olymp Ro 43 Gil, Seoul, South Korea
关键词
magnetic resonance imaging; quantitative image analysis; MR-angiography (MRA); METASTASES; MANAGEMENT; MRI; CT; ENHANCEMENT; DIAGNOSIS;
D O I
10.4283/JMAG.2016.21.2.281
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The purpose of study was to evaluate SNR and CNR with different contrast agent contents (1.0 mmo/mL gadobutrol and 0.5 mmol/mL gadoterate meglumine) for spin echo (SE) and 3-dimension contrast-enhanced fast field echo (3D CE-FFE) pulse sequences. In this study, we compared the SNR and the CNR between 0.5 mmol/mL gadoterate meglumine and 1.0 mmol/mL gadobutrol according to the concentration of contrast agent in brain MRI. When we compared between SE and 3D CE-FFE pulse sequences, the higher SNR and CNR using 3D CE-FFE pulse sequence can be acquire regardless of contrast agent contents. Also, a statistically significant difference was found for SNR and CNR between all protocols. In conclusion, our results demonstrated that the SNR and CNR have not risen proportionately with contrast agent contents. We hope that these results presented in this paper will contribute to decide contrast agent contents for brain MRI.
引用
收藏
页码:281 / 285
页数:5
相关论文
共 14 条
[1]   Comparative Evaluation of Lesion Enhancement Using 1 M Gadobutrol vs. 2 Conventional Gadolinium Chelates, All at a Dose of 0.1 mmol/kg, in a Rat Brain Tumor Model at 3 T [J].
Attenberger, Ulrike I. ;
Runge, Val M. ;
Jackson, Carney B. ;
Baumann, Shannon ;
Birkemeier, Krista ;
Michaely, Henrik J. ;
Schoenberg, Stefan O. ;
Reiser, Maximilian F. ;
Wintersperger, Bernd J. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (05) :251-256
[2]   Macromolecular MRI contrast agents for imaging tumor angiogenesis [J].
Barrett, Tristan ;
Kobayashi, Hisataka ;
Brechbiel, Martin ;
Choyke, Peter L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 60 (03) :353-366
[3]   Brain tumor enhancement in magnetic resonance imaging - Comparison of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at 1.5 versus 3 Tesla [J].
Biswas, J ;
Nelson, CB ;
Runge, VM ;
Wintersperger, BJ ;
Baumann, SS ;
Jackson, CB ;
Patel, T .
INVESTIGATIVE RADIOLOGY, 2005, 40 (12) :792-797
[4]   3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T [J].
Chang, Kevin J. ;
Kamel, Ihab R. ;
Macura, Katarzyna J. ;
Bluemke, David A. .
RADIOGRAPHICS, 2008, 28 (07) :1983-1998
[5]  
DAVIS PC, 1991, AM J NEURORADIOL, V12, P293
[6]   Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery [J].
Filippi, M ;
Yousry, T ;
Baratti, C ;
Horsfield, MA ;
Mammi, S ;
Becker, C ;
Voltz, R ;
Spuler, S ;
Campi, A ;
Reiser, MF ;
Comi, G .
BRAIN, 1996, 119 :1349-1355
[7]   Scatter correction using a primary modulator for dual energy digital radiography: A Monte Carlo simulation study [J].
Jo, Byung-Du ;
Lee, Young-Jin ;
Kim, Dae-Hong ;
Kim, Hee-Joung .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (04) :541-552
[8]  
Kellner CP, 2011, NEUROSURG CLIN N AM, V22, P53, DOI 10.1016/j.nec.2010.08.003
[9]   Gadolinium-based MR contrast agents and nephrogenic systemic fibrosis [J].
Kuo, Phillip H. ;
Kanal, Emanuel ;
Abu-Alfa, Ali K. ;
Cowper, Shawn E. .
RADIOLOGY, 2007, 242 (03) :647-649
[10]   Review of Imaging Techniques in the Diagnosis and Management of Brain Metastases [J].
Lignelli, Angela ;
Khandji, Alexander G. .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2011, 22 (01) :15-+