Comparison between tomographic scanning evaluation and photographic measurement of the neuroretinal rim

被引:39
作者
Dichtl, A [1 ]
Jonas, JB [1 ]
Mardin, CY [1 ]
机构
[1] UNIV ERLANGEN NURNBERG,DEPT OPHTHALMOL,D-91054 ERLANGEN,GERMANY
关键词
D O I
10.1016/S0002-9394(14)75423-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare laser tomographic scanning evaluation with photographic measurement of size and shape of the neuroretinal rim. METHODS: For 25 normal eyes and 32 glaucomatous eyes, the optic disks were examined with the Heidelberg Retina Tomograph (software version 1.11) for confocal laser tomographic scanning evaluation, and color stereoscopic optic disk photographs for planimetric measurements, Area and width of the neuroretinal rim were determined as percentages of the disk area and diameter, respectively. RESULTS: For the normal and glaucomatous eyes, the tomographic results compared with the photographic measurements disclosed significantly larger values for the relative width and relative area of the neuroretinal rim, The differences between both methods were most marked in the nasal part of the optic disk and least marked in the temporal disk region, The relative differences increased significantly (P <.05) with increasing degree of glaucomatous optic nerve damage. CONCLUSIONS: In normal and glaucomatous eyes, the Heidelberg Retina Tomograph determines the neuroretinal rim, expressed as percentage of optic disk measurements, to be significantly larger than when the rim is evaluated on optic disk photographs, Because parts of the central retinal vessel trunk are defined as neuroretinal rim in the algorithm of the Heidelberg Retina Tomograph, the differences between Heidelberg Retina Tomograph measurements and photographic determinations of the rim are largest in the nasal disk region and smallest in the temporal disk area, The neuroretinal rim shape and neuroretinal rim area differ appreciably between the two methods, These differences increase with increasing degree of glaucomatous optic nerve damage.
引用
收藏
页码:494 / 501
页数:8
相关论文
共 29 条
[11]   OPTIC-NERVE HEAD ANALYZER AND HEIDELBERG RETINA TOMOGRAPH - ACCURACY AND REPRODUCIBILITY OF TOPOGRAPHIC MEASUREMENTS IN A MODEL EYE AND IN VOLUNTEERS [J].
JANKNECHT, P ;
FUNK, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (10) :760-768
[12]  
JONAS JB, 1989, INVEST OPHTH VIS SCI, V30, P1599
[13]  
JONAS JB, 1989, OPHTHALMOLOGY, V96, P627
[14]  
JONAS JB, 1991, INVEST OPHTH VIS SCI, V32, P401
[15]   VISIBILITY OF THE NORMAL RETINAL NERVE-FIBER LAYER CORRELATED WITH RIM WIDTH AND VESSEL CALIBER [J].
JONAS, JB ;
SCHIRO, D .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1993, 231 (04) :207-211
[16]  
JONAS JB, 1988, INVEST OPHTH VIS SCI, V29, P1151
[17]   OPTIC DISK APPEARANCE IN OCULAR HYPERTENSIVE EYES [J].
JONAS, JB ;
KONIGSREUTHER, KA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 117 (06) :732-740
[18]   OPTIC DISK MORPHOMETRY IN HIGH MYOPIA [J].
JONAS, JB ;
GUSEK, GC ;
NAUMANN, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1988, 226 (06) :587-590
[19]  
JONAS JB, 1993, OPHTHALMOLOGY, V99, P63
[20]  
JONAS JB, 1992, INVEST OPHTH VIS SCI, V33, P474