Wound Complications and Clinical Results of Electrocautery Versus a Scalpel to Create a Cutaneous Flap in Thyroidectomy: A Prospective Randomized Trial

被引:6
作者
Uludag, Mehmet [1 ]
Yetkin, Gurkan [1 ]
Ozel, Alper [2 ]
Ozguven, M. Banu Yilmaz [3 ]
Yener, Senay [3 ]
Isgor, Adnan [4 ]
机构
[1] Sisli Etfal Training & Res Hosp, Dept Gen Surg 2, Istanbul, Turkey
[2] Sisli Etfal Training & Res Hosp, Dept Radiol, Istanbul, Turkey
[3] Sisli Etfal Training & Res Hosp, Dept Pathol, Istanbul, Turkey
[4] Halic Univ Hlth Sci Inst, Istanbul, Turkey
关键词
Thyroidectomy; Subplatysmal flap dissection; Cutaneous flap; Electrocautery; Scalpel; VIDEO-ASSISTED THYROIDECTOMY; SURGERY; INCISIONS; MASTECTOMY; PREVENTION; MORBIDITY; INFECTION; DIATHERMY; SEROMA;
D O I
10.1007/s00595-010-4435-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose. The use of electrocautery for tissue dissection is becoming increasingly popular, despite the associated risk of poor wound healing and excessive scarring. We conducted this study to compare the wound complications and early and late clinical results resulting from electrocautery versus the scalpel to create a cutaneous flap during thyroidectomy. Methods. The subjects of this study were 100 patients, randomized prospectively to either a scalpel group (group S, n = 50) or an electrocautery group (group E, n = 50). Results. Thickness of tissue damage, postoperative thickness of the flap, discomfort in the neck 7 days after surgery, and hypoesthesia and paresthesia in the neck 3 months after surgery were significantly higher in group E than in group S. There were no significant differences in overall postoperative wound complications, postoperative pain, satisfaction with the cosmetic result, or overall outcome of the operation between the groups. Although the incidence of seroma was higher in group E (20%) than in group S (8%), the difference was not significant. Conclusion. Although electrocautery was associated with increased histological tissue damage, postoperative flap edema, discomfort, and other complications in the early stage, the clinical and cosmetic results of flaps made using electrocautery or a scalpel were similar and satisfactory 6 months after surgery.
引用
收藏
页码:1041 / 1048
页数:8
相关论文
共 34 条
  • [1] [Anonymous], 2006, SURG INFECT, DOI DOI 10.1089/SUR.2006.7.S2-117
  • [2] ARENDS MJ, 1991, INT REV EXP PATHOL, V32, P223
  • [3] AYYASH K, 1991, ACTA CHIR-EUR J SURG, V157, P113
  • [4] Electrocautery for cutaneous flap creation during thyroidectomy: a randomised, controlled study
    Barbaros, U.
    Erbil, Y.
    Aksakal, N.
    Citlak, G.
    Issever, H.
    Bozbora, A.
    Ozarmagan, S.
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2008, 122 (12) : 1343 - 1348
  • [5] Video-assisted vs conventional thyroid lobectomy - A randomized trial
    Bellantone, R
    Lombardi, CP
    Bossola, M
    Boscherini, M
    De Crea, C
    Alesina, PF
    Traini, E
    [J]. ARCHIVES OF SURGERY, 2002, 137 (03) : 301 - 304
  • [6] Morbidity of thyroid surgery
    Bergamaschi, R
    Becouarn, G
    Ronceray, J
    Arnaud, JP
    [J]. AMERICAN JOURNAL OF SURGERY, 1998, 176 (01) : 71 - 75
  • [7] Böhm B, 2005, CHIRURG, V76, P54, DOI 10.1007/s00104-004-0918-5
  • [8] Chrysos E, 2005, AM SURGEON, V71, P326
  • [9] Dionigi G, 2008, Int J Surg, V6 Suppl 1, pS13, DOI 10.1016/j.ijsu.2008.12.024
  • [10] Cell death and proliferation in Nd-YAG laser, electrocautery, and scalpel wounds on mice skin
    Fukuda, Y
    Ito, Y
    Azumi, H
    Eid, NAS
    Li, ZL
    Marumo, M
    Kasagawa, O
    Otsuki, Y
    [J]. JOURNAL OF DERMATOLOGICAL SCIENCE, 2002, 28 (02) : 106 - 118