Characterization of Silicon Photomultipliers after proton irradiation up to 1014 neq/cm2

被引:10
作者
Altamura, Anna Rita [1 ,2 ,3 ]
Acerbi, Fabio [1 ,3 ]
Nociforo, Chiara [4 ]
Regazzoni, Veronica [1 ]
Mazzi, Alberto [1 ,3 ]
Gola, Alberto [1 ,3 ]
机构
[1] Fdn Bruno Kessler FBK, Sensors & Devices SD, Via Sommar 18, I-38123 Trento, Italy
[2] Univ Udine, Via Palladio 8, I-33100 Udine, Italy
[3] TIFPA Trento Inst Fundamental Phys & Applicat, Via Sommar 14, I-38123 Trento, Italy
[4] GSI Helmholtzzentrum Schwerionenforsch Darmstadt, Darmstadt, Germany
关键词
Silicon photomultipliers; SiPM; Radiation damage; Protons; Noise; Crosstalk; Emission microscopy; DAMAGE;
D O I
10.1016/j.nima.2022.167284
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon photomultipliers (SiPMs) are highly-sensitive photodetectors emerging as the technology of choice for many applications, including large high-energy physics experiments where they often are exposed to high radiation fluences. In recent years, there has been an increasing interest in assessing the performance deterioration of such detectors after the irradiation with proton or neutron, with different fluence levels. In this work, samples of different FBK SiPM technologies, made with different manufacturing technologies, were irradiated at the INFN-LNS facility (Italy) with protons reaching fluences up to about 10(14) n(eq)/cm(2) (1 MeV neutron equivalent) and their performances were characterized in detail after about 30-days room temperature annealing. The results show a significant worsening of the primary noise (dark count rate) of the detectors, which increases with the irradiation fluence, whereas the other performance parameters like the micro-cell gain, the correlated noise probability and the photon detection efficiency do not show significant variations up to 10(11) n(eq)/cm(2) at least. The breakdown voltage estimation after irradiation is another important aspect for a SiPM. In this contribution, we show several methods for its estimation and compare the results. We also introduced new methodologies to characterize the performance of the SiPMs when they present a very high level of noise, such as the estimation of the dark count rate based on the measured reverse current, the estimation of variations in the photon detection efficiency through the measurement of the responsivity, and the measurement of the correlated noise and the gain through the average charge in response to a pulsed light signal. Lastly, we also analyzed the spatial localization of the proton-induced defects inside the device, i.e. the defects that mostly contribute to the increase of the DCR of the device, through the emission microscopy (EMMI) technique. In particular, we analyzed the SiPMs at the single cell level, trying to identify and spatially localize the defects.
引用
收藏
页数:14
相关论文
共 38 条
[1]  
Acerbi Fabio, 2019, Instruments, V3, DOI 10.3390/instruments3010015
[2]   Understanding and simulating SiPMs [J].
Acerbi, Fabio ;
Gundacker, Stefan .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 926 :16-35
[3]   High-Density Silicon Photomultipliers: Performance and Linearity Evaluation for High Efficiency and Dynamic-Range Applications [J].
Acerbi, Fabio ;
Paternoster, Giovanni ;
Gola, Alberto ;
Regazzoni, Veronica ;
Zorzi, Nicola ;
Piemonte, Claudio .
IEEE JOURNAL OF QUANTUM ELECTRONICS, 2018, 54 (02)
[4]   High Efficiency, Ultra-High-Density Silicon Photomultipliers [J].
Acerbi, Fabio ;
Gola, Alberto ;
Regazzoni, Veronica ;
Paternoster, Giovanni ;
Borghi, Giacomo ;
Zorzi, Nicola ;
Piemonte, Claudio .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2018, 24 (02)
[5]  
Advansid, 2014, INTR SIPMS
[6]   A multimechanism model for photon generation by silicon junctions in avalanche breakdown [J].
Akil, N ;
Kerns, SE ;
Kerns, DV ;
Hoffmann, A ;
Charles, JP .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1999, 46 (05) :1022-1028
[7]   Mitigating radiation damage of single photon detectors for space applications [J].
Anisimova, Elena ;
Higgins, Brendon L. ;
Bourgoin, Jean-Philippe ;
Cranmer, Miles ;
Choi, Eric ;
Hudson, Danya ;
Piche, Louis P. ;
Scott, Alan ;
Makarov, Vadim ;
Jennewein, Thomas .
EPJ QUANTUM TECHNOLOGY, 2017, 4
[8]   Tests of a dual-readout fiber calorimeter with SiPM light sensors [J].
Antonello, M. ;
Caccia, M. ;
Cascella, M. ;
Dunser, M. ;
Ferrari, R. ;
Franchino, S. ;
Gaudio, G. ;
Hall, K. ;
Hauptman, J. ;
Jo, H. ;
Kang, K. ;
Kim, B. ;
Lee, S. ;
Lerner, G. ;
Pezzotti, L. ;
Santoro, R. ;
Vivarelli, I. ;
Ye, R. ;
Wigmans, R. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 899 :52-64
[9]   Temperature dependence of the current generated in Si bulk [J].
Chilingarov, A. .
JOURNAL OF INSTRUMENTATION, 2013, 8
[10]   Study of the breakdown voltage of SiPMs [J].
Chmill, V. ;
Garutti, E. ;
Klanner, R. ;
Nitschke, M. ;
Schwandt, J. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 :56-59