Simulation and Structure Optimization of Grounding Circuit Model for Power Transmission Line Tower

被引:0
|
作者
Hu, Yuanchao [1 ]
Cheng, Yan [1 ]
Jiang, Zhipeng [2 ]
An, Yunzhu [1 ]
Jeon, Seunggil [3 ]
Zhou, Wen [4 ]
机构
[1] Shandong Univ Technol, Sch Elect & Elect Engn, 266 West Xincun Rd, Zibo, Shandong, Peoples R China
[2] Ezhou Power Supply Co, State Grid Hubei Power Supply Ltd Co, Ezhou, Hubei, Peoples R China
[3] Samsung Elect, 129 Samseong Ro, Suwon 16677, Gyeonggi Do, South Korea
[4] Huanglongtan Hydropower Plant State Grid Hubei El, Shiyan, Hubei, Peoples R China
关键词
Excavated pile foundation; grounding resistance; current density; resistance reduction efficiency; flexible graphite grounding electrode; INFRASTRUCTURE;
D O I
10.1142/S0218126622502784
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The lightning current dispersion process through the steel bar inside the concrete pile foundation of the transmission line tower is impeded by the high concrete resistivity. In order to improve the current dispersion performance of the pile foundation, this paper proposes a method to place flexible graphite grounding electrode along the shaft wall of the tower foundation and verified its feasibility. Both single-pile and four-pile foundations are applied to build vertical grounding models of transmission line tower with three different grounding structures, respectively, including flexible graphite grounding line, flexible graphite grounding fabric and combined graphite electrode. The effect of three grounding structures on the current dispersion and resistance reduction is studied by finite-element method. Simulation results indicate that by applying the above three grounding structures on the vertical pile foundation can significantly improve the current density distribution of the excavated pile foundation and reduce the grounding resistance. When the grounding resistance is 200 Omega . m, the resistance reduction efficiencies of the above three methods can reach 48.56%, 53.86% and 54.53%, respectively. Considering the limited construction area, this paper compares the foundation that is placed combined graphite grounding electrode with square-ray grounding grid, and it can be seen that by placing vertical grounding electrode can save the land area of 295.99 m(2). This paper can provide reference for the design of excavation pile foundation grounding structure under limited construction area.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Power Frequency Interference and Suppression in Measurement of Power Transmission Tower Grounding Resistance
    Zhou, Wenjun
    Liu, Yushun
    Li, Gongxin
    Yan, Guozhi
    Yang, Shuai
    Li, Han
    Zhou, Chengke
    Su, Charles Qi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 1016 - 1023
  • [22] Development of a transmission line model for calculating line parameters considering finite line length and tower propagation resistances at grounding points
    Nguyen, Thanh Binh
    Liebermann, Carlo
    Schegner, Peter
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2024, 141 (05): : 315 - 324
  • [23] METHOD OF ESTIMATING THE GROUNDING RESISTANCE OF POWER TRANSMISSION TOWER FOUNDATION.
    Noda, Masanobu
    Kinoshita, Hitoshi
    Matsubara, Ichiro
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1987, 107 (04): : 68 - 76
  • [24] A multiconductor transmission line model for grounding grids
    Jardines, A.
    Guardado, J. L.
    Torres, J.
    Chavez, J. J.
    Hernandez, M.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 60 : 24 - 33
  • [25] A Multiconductor Transmission Line Model For Grounding Systems
    Guardado, J. L.
    Torres, J.
    Fuerte, C. R.
    Venegas, V.
    Melgoza, E.
    POWER '09: PROCEEDINGS OF THE 9TH WSEAS/IASME INTERNATIONAL CONFERENCE ON ELECTRIC POWER SYSTEMS, HIGH VOLTAGES, ELECTRIC MACHINES, 2009, : 115 - +
  • [26] Choosing configurations of transmission line tower grounding by back flashover probability value
    Kuklin, Dmitry
    FRONTIERS IN ENERGY, 2016, 10 (02) : 213 - 226
  • [27] Investigation of Seasonal Variations of Tower Footing Impedance in Transmission Line Grounding Systems
    Wang, Chenyang
    Liang, Xiaodong
    Adajar, Emerson P.
    Loewen, Paul
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (03) : 2274 - 2284
  • [28] Choosing configurations of transmission line tower grounding by back flashover probability value
    Dmitry KUKLIN
    Frontiers in Energy, 2016, 10 (02) : 213 - 226
  • [29] SIMPLIFIED HV TOWER GROUNDING SYSTEM MODEL FOR BACKFLASHOVER SIMULATION
    Geri, A.
    Gatta, F. M.
    Lauria, S.
    Maccioni, M.
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [30] An EMTP Comprehensive Model of Tower Grounding and its Simulation Analysis
    Wang, Zicheng
    Zhang, Yadong
    Guo, Jin
    Luo, Rong
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199