Transfer of dry surface biofilm in the healthcare environment: the role of healthcare workers' hands as vehicles

被引:45
作者
Chowdhury, D. [1 ]
Tahir, S. [1 ]
Legge, M. [1 ]
Hu, H. [1 ]
Prvan, T. [2 ]
Johani, K. [1 ,3 ,4 ]
Whiteley, G. S. [5 ,6 ]
Glasbey, T. O. [1 ,6 ]
Deva, A. K. [1 ]
Vickery, K. [1 ]
机构
[1] Macquarie Univ, Surg Infect Res Grp, Fac Med & Hlth Sci, Sydney, NSW, Australia
[2] Macquarie Univ, Dept Stat, Sydney, NSW, Australia
[3] Prince Sultan Mil Med City, Cent Mil Labs, Riyadh, Saudi Arabia
[4] Prince Sultan Mil Med City, Blood Bank, Riyadh, Saudi Arabia
[5] Western Sydney Univ, Sch Med, Campbelltown, NSW, Australia
[6] Whiteley Corp Pty Ltd, Sydney, NSW, Australia
基金
澳大利亚研究理事会;
关键词
Dry surface biofilms; Transmission; Cleaning; Healthcare-associated infections; Staphylococcus aureus; TRANSFER EFFICIENCY; INFECTION; CONTAMINATION; ACQUISITION; BACTERIA; UNIT;
D O I
10.1016/j.jhin.2018.06.021
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Dry surface biofilms (DSBs) persist for extended periods in hospital, and may play a significant role in transmission of healthcare-associated infections. Aim: To determine whether DSBs may be transferred from hospital surfaces to healthcare workers' hands. Method: Twelve-day Staphylococcus aureus DSB was grown on polycarbonate and glass coupons in a CDC Biofilm Reactor (R). A total of 1.8 x 10(6) and 8.8 x 10(5) bacteria grew on the polycarbonate and glass coupons respectively. Transmission was tested by lifting the coupon with forefinger and thumb of ungloved hands to a height of 30 cm, then touching horse blood agar (HBA) plates 19 sequential times. Transferred bacterial number was determined by colony-forming units. The effect of DSB wetting on biofilm transfer was tested with 5% neutral detergent treatment for 5 s. Findings: Between 5.5 and 6.6% of the DSB bacteria were transferred to hands with one touch and similar to 20% were then transferred to HBA with one touch, giving an overall transfer rate of 1.26% and 1.04% for polycarbonate and glass coupons, respectively. Detergent treatment had little effect on bacterial removal from coupons, but, for biofilm grown on polycarbonate, significantly increased transferral to HBA (P < 0.001) to 5.2%. Large numbers of bacteria were transferred by bare hands to multiple fomites. One-third of polycarbonate coupons transferred >1000 colonies during the first five sequential touches. Sufficient bacteria to cause infection were transmitted up to 19 times following one touch of the DSB. Conclusion: DSB bacteria are transferred by hands from one fomite to multiple fomites, suggesting that DSB may serve as a persistent environmental source of pathogens. (C) 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E85 / E90
页数:6
相关论文
共 18 条
[1]   Staphylococcus aureus dry-surface biofilms are not killed by sodium hypochlorite: implications for infection control [J].
Almatroudi, A. ;
Gosbell, I. B. ;
Hu, H. ;
Jensen, S. O. ;
Espedido, B. A. ;
Tahir, S. ;
Glasbey, T. O. ;
Legge, P. ;
Whiteley, G. ;
Deva, A. ;
Vickery, K. .
JOURNAL OF HOSPITAL INFECTION, 2016, 93 (03) :263-270
[2]   A new dry-surface biofilm model: An essential tool for efficacy testing of hospital surface decontamination procedures [J].
Almatroudi, Ahmad ;
Hu, Honghua ;
Deva, Anand ;
Gosbell, Iain B. ;
Jacombs, Anita ;
Jensen, Slade O. ;
Whiteley, Greg ;
Glasbey, Trevor ;
Vickery, Karen .
JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 117 :171-176
[3]   Environmental contamination makes an important contribution to hospital infection [J].
Boyce, John M. .
JOURNAL OF HOSPITAL INFECTION, 2007, 65 :50-54
[4]   Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition:: the case for hospital cleaning [J].
Dancer, Stephanie J. .
LANCET INFECTIOUS DISEASES, 2008, 8 (02) :101-113
[5]  
FOSTER WD, 1960, LANCET, V2, P1373
[6]   Fomite-fingerpad transfer efficiency (pick-up and deposit) of Acinetobacter baumannii-with and without a latex glove [J].
Greene, Christine ;
Vadlamudi, Gayathri ;
Eisenberg, Marisa ;
Foxman, Betsy ;
Koopman, James ;
Xi, Chuanwu .
AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (09) :928-934
[7]   Interventional evaluation of environmental contamination by vancomycin-resistant enterococci: failure of personnel, product, or procedure? [J].
Hota, B. ;
Blom, D. W. ;
Lyle, E. A. ;
Weinstein, R. A. ;
Hayden, M. K. .
JOURNAL OF HOSPITAL INFECTION, 2009, 71 (02) :123-131
[8]   Intensive care unit environmental surfaces are contaminated by multidrug-resistant bacteria in biofilms: combined results of conventional culture, pyrosequencing, scanning electron microscopy, and confocal laser microscopy [J].
Hu, H. ;
Johani, K. ;
Gosbell, I. B. ;
Jacombs, A. S. W. ;
Almatroudi, A. ;
Whiteley, G. S. ;
Deva, A. K. ;
Jensen, S. ;
Vickery, K. .
JOURNAL OF HOSPITAL INFECTION, 2015, 91 (01) :35-44
[9]   Microbial Assessment of High-, Medium-, and Low-Touch Hospital Room Surfaces [J].
Huslage, Kirk ;
Rutala, William A. ;
Gergen, Maria F. ;
Sickbert-Bennett, Emily E. ;
Weber, David J. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (02) :211-212
[10]   How long do nosocomial pathogens persist on inanimate surfaces? A systematic review [J].
Kramer, Axel ;
Schwebke, Ingeborg ;
Kampf, Guenter .
BMC INFECTIOUS DISEASES, 2006, 6 (1)