Transfer of dry surface biofilm in the healthcare environment: the role of healthcare workers' hands as vehicles

被引:43
作者
Chowdhury, D. [1 ]
Tahir, S. [1 ]
Legge, M. [1 ]
Hu, H. [1 ]
Prvan, T. [2 ]
Johani, K. [1 ,3 ,4 ]
Whiteley, G. S. [5 ,6 ]
Glasbey, T. O. [1 ,6 ]
Deva, A. K. [1 ]
Vickery, K. [1 ]
机构
[1] Macquarie Univ, Surg Infect Res Grp, Fac Med & Hlth Sci, Sydney, NSW, Australia
[2] Macquarie Univ, Dept Stat, Sydney, NSW, Australia
[3] Prince Sultan Mil Med City, Cent Mil Labs, Riyadh, Saudi Arabia
[4] Prince Sultan Mil Med City, Blood Bank, Riyadh, Saudi Arabia
[5] Western Sydney Univ, Sch Med, Campbelltown, NSW, Australia
[6] Whiteley Corp Pty Ltd, Sydney, NSW, Australia
基金
澳大利亚研究理事会;
关键词
Dry surface biofilms; Transmission; Cleaning; Healthcare-associated infections; Staphylococcus aureus; TRANSFER EFFICIENCY; INFECTION; CONTAMINATION; ACQUISITION; BACTERIA; UNIT;
D O I
10.1016/j.jhin.2018.06.021
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Dry surface biofilms (DSBs) persist for extended periods in hospital, and may play a significant role in transmission of healthcare-associated infections. Aim: To determine whether DSBs may be transferred from hospital surfaces to healthcare workers' hands. Method: Twelve-day Staphylococcus aureus DSB was grown on polycarbonate and glass coupons in a CDC Biofilm Reactor (R). A total of 1.8 x 10(6) and 8.8 x 10(5) bacteria grew on the polycarbonate and glass coupons respectively. Transmission was tested by lifting the coupon with forefinger and thumb of ungloved hands to a height of 30 cm, then touching horse blood agar (HBA) plates 19 sequential times. Transferred bacterial number was determined by colony-forming units. The effect of DSB wetting on biofilm transfer was tested with 5% neutral detergent treatment for 5 s. Findings: Between 5.5 and 6.6% of the DSB bacteria were transferred to hands with one touch and similar to 20% were then transferred to HBA with one touch, giving an overall transfer rate of 1.26% and 1.04% for polycarbonate and glass coupons, respectively. Detergent treatment had little effect on bacterial removal from coupons, but, for biofilm grown on polycarbonate, significantly increased transferral to HBA (P < 0.001) to 5.2%. Large numbers of bacteria were transferred by bare hands to multiple fomites. One-third of polycarbonate coupons transferred >1000 colonies during the first five sequential touches. Sufficient bacteria to cause infection were transmitted up to 19 times following one touch of the DSB. Conclusion: DSB bacteria are transferred by hands from one fomite to multiple fomites, suggesting that DSB may serve as a persistent environmental source of pathogens. (C) 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E85 / E90
页数:6
相关论文
共 18 条
  • [1] Staphylococcus aureus dry-surface biofilms are not killed by sodium hypochlorite: implications for infection control
    Almatroudi, A.
    Gosbell, I. B.
    Hu, H.
    Jensen, S. O.
    Espedido, B. A.
    Tahir, S.
    Glasbey, T. O.
    Legge, P.
    Whiteley, G.
    Deva, A.
    Vickery, K.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2016, 93 (03) : 263 - 270
  • [2] A new dry-surface biofilm model: An essential tool for efficacy testing of hospital surface decontamination procedures
    Almatroudi, Ahmad
    Hu, Honghua
    Deva, Anand
    Gosbell, Iain B.
    Jacombs, Anita
    Jensen, Slade O.
    Whiteley, Greg
    Glasbey, Trevor
    Vickery, Karen
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2015, 117 : 171 - 176
  • [3] Environmental contamination makes an important contribution to hospital infection
    Boyce, John M.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2007, 65 : 50 - 54
  • [4] Importance of the environment in meticillin-resistant Staphylococcus aureus acquisition:: the case for hospital cleaning
    Dancer, Stephanie J.
    [J]. LANCET INFECTIOUS DISEASES, 2008, 8 (02) : 101 - 113
  • [5] FOSTER WD, 1960, LANCET, V2, P1373
  • [6] Fomite-fingerpad transfer efficiency (pick-up and deposit) of Acinetobacter baumannii-with and without a latex glove
    Greene, Christine
    Vadlamudi, Gayathri
    Eisenberg, Marisa
    Foxman, Betsy
    Koopman, James
    Xi, Chuanwu
    [J]. AMERICAN JOURNAL OF INFECTION CONTROL, 2015, 43 (09) : 928 - 934
  • [7] Interventional evaluation of environmental contamination by vancomycin-resistant enterococci: failure of personnel, product, or procedure?
    Hota, B.
    Blom, D. W.
    Lyle, E. A.
    Weinstein, R. A.
    Hayden, M. K.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2009, 71 (02) : 123 - 131
  • [8] Intensive care unit environmental surfaces are contaminated by multidrug-resistant bacteria in biofilms: combined results of conventional culture, pyrosequencing, scanning electron microscopy, and confocal laser microscopy
    Hu, H.
    Johani, K.
    Gosbell, I. B.
    Jacombs, A. S. W.
    Almatroudi, A.
    Whiteley, G. S.
    Deva, A. K.
    Jensen, S.
    Vickery, K.
    [J]. JOURNAL OF HOSPITAL INFECTION, 2015, 91 (01) : 35 - 44
  • [9] Microbial Assessment of High-, Medium-, and Low-Touch Hospital Room Surfaces
    Huslage, Kirk
    Rutala, William A.
    Gergen, Maria F.
    Sickbert-Bennett, Emily E.
    Weber, David J.
    [J]. INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (02) : 211 - 212
  • [10] How long do nosocomial pathogens persist on inanimate surfaces? A systematic review
    Kramer, Axel
    Schwebke, Ingeborg
    Kampf, Guenter
    [J]. BMC INFECTIOUS DISEASES, 2006, 6 (1)