Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study

被引:8
|
作者
Montorsi, P [1 ]
Galli, S [1 ]
Fabbiocchi, F [1 ]
Loaldi, A [1 ]
Trabattoni, D [1 ]
Grancini, L [1 ]
Cozzi, S [1 ]
Ravagnani, P [1 ]
Parodi, O [1 ]
Bartorelli, AL [1 ]
机构
[1] Univ Milan, Inst Cardiol, Ctr Cardiol Monzino, IRCCS, I-20138 Milan, Italy
关键词
cutting balloon; in-stent restenosis; intravascular ultrasound;
D O I
10.1002/ccd.10191
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated by intravascular ultrasound (IVUS) the mechanism of action of cutting balloon (CB) angioplasty in patients with in-stent restenosis. Seventy-one consecutive restenotic lesions of 66 patients were studied by quantitative coronary angiography (QCA) and IVUS before, immediately after, and, in 20 cases, at 24-hr time interval after CB. CB was selected according to 1:1 CB-to-stent ratio and inflated at 8 atm for 60-90 sec. Both IVUS planar and volumetric (Simpson's rule, 25 patients) analysis were carried out. IVUS measurements included external elastic membrane area (EEMA), stent area (SA), minimal lumen area (MLA), and restenosis area (RA). Following CB, OCA analysis showed increase of minimal lumen diameter (1.17 +/- 0.46 vs. 2.45 +/- 0.51 mm; P < 0.0001) and decrease of diameter stenosis (64% +/- 13% vs. 21% +/- 9%; P < 0.0001). IVUS measurements showed a significant increase of MLA (2.18 +/- 0.80 vs. 7.31 +/- 1.8 mm(2); p < 0.0001), SA (9.62 +/- 2.6 vs. 10.7 +/- 2.75 mm(2); p < 0.0001), and EEMA (117.27 +/- 5 vs. 18.1 +/- 5 mm(2); P < 0.0001) and a decrease of RA (7.43 +/- 2.63 vs. 3.45 +/- 1.39 mm(2); p < 0.0001). No significant change was observed in the original plaque + media area (7.65 +/- 3 vs. 7.38 +/- 2.9 mm(2); p = NS). Thus, of the total lumen enlargement (5.13 +/- 1.85 mm(2)), 23% was the result of increase in mean SA, whereas 77% was the result of a decrease in mean RA. These changes were associated with a 5% increase in EEMA. IVUS volumetric changes paralleled planar variations. Angiographic and IVUS changes were well maintained at 24 hr. CB enlarges coronary lumen mainly by in-stent tissue reduction associated with a moderate degree of additional stent expansion. Favorable QCA and IVUS acute results are maintained at 24 hr. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 50 条
  • [21] Mechanisms of In-Stent Restenosis After Drug-Eluting Stent Implantation Intravascular Ultrasound Analysis
    Kang, Soo-Jin
    Mintz, Gary S.
    Park, Duk-Woo
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Han, Ki-Hoon
    Kim, Jae-Joong
    Park, Seong-Wook
    Park, Seung-Jung
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (01) : 9 - 14
  • [22] Mechanisms of balloon angioplasty and repeat stenting in patients with drug-eluting in-stent restenosis
    Alfonso, Fernando
    Sandoval, Jorge
    Perez-Vizcayno, Maria J.
    Cardenas, Alberto
    Gonzalo, Nieves
    Jimenez-Quevedo, Pilar
    Ibanez, Borja
    Nunez-Gil, Ivan
    Rivero, Fernando
    Escaned, Javier
    Fernandez-Ortiz, Antonio
    Macaya, Carlos
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 178 : 213 - 220
  • [23] Carotid Duplex Ultrasound Velocity Measurements Versus Intravascular Ultrasound in Detecting Carotid In-Stent Restenosis
    Yan, Bryan P.
    Clark, David J.
    Jaff, Michael R.
    Kiernan, Thomas J.
    Schainfeld, Robert M.
    Lessio, Sara
    Rosenfield, Kenneth
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) : 438 - 443
  • [24] The role of brachytherapy and cutting balloon™ angioplasty in the current treatment of stent restenosis
    Bonan, R
    CORONARY ARTERY DISEASE, 2004, 15 (06) : 319 - 325
  • [25] Arterial response during cutting balloon angioplasty: A volumetric intravascular ultrasound study
    Liao, CK
    Bonneau, HN
    Yock, PG
    Fitzgerald, PJ
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2002, 101 (11) : 756 - 761
  • [26] Intravascular Imaging for Guiding In-Stent Restenosis and Stent Thrombosis Therapy
    Erdogan, Emrah
    Bajaj, Retesh
    Lansky, Alexandra
    Mathur, Anthony
    Baumbach, Andreas
    Bourantas, Christos, V
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (22):
  • [27] Intravascular ultrasound predictors of restenosis after balloon angioplasty of the femoropopliteal artery
    van der Lugt, A
    Gussenhoven, EJ
    Pasterkamp, G
    Stijnen, T
    Reekers, JA
    van den Berg, FG
    Tielbeek, AV
    Seelen, JL
    Pieterman, H
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (02) : 110 - 119
  • [28] Iatrogenic Acute Coronary Dissection During Coronary Angioplasty for In-Stent Restenosis: Role of Intravascular Ultrasound in Diagnosis and Treatment
    Park, Chang-Bum
    Park, Hoon-Ki
    Kim, Chong-Jin
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (01): : E1 - E2
  • [29] Predictors of Recurrent In-Stent Restenosis After Paclitaxel-Coated Balloon Angioplasty
    Koiwaya, Hiroshi
    Watanabe, Nozomi
    Kuriyama, Nehiro
    Nishino, Shun
    Ogata, Kenji
    Kimura, Toshiyuki
    Nakama, Tatsuya
    Matsuura, Hirohide
    Furugen, Makoto
    Shibata, Yoshisato
    CIRCULATION JOURNAL, 2017, 81 (09) : 1286 - +
  • [30] Drug-Eluting Balloon Angioplasty for In-Stent Restenosis Following Carotid Artery Stent Placement
    Bhatia, Kunal
    Akhtar, Iqra N.
    Akinci, Yasemin
    Liaqat, Jahanzeb
    Siddiq, Farhan
    Gomez, Camilo R.
    Qureshi, Adnan I.
    JOURNAL OF NEUROIMAGING, 2020, 30 (03) : 267 - 275