Mass Analyzers and Mass Spectrometers

被引:41
作者
Haag, Anthony M. [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Texas Childrens Microbiome Ctr, Houston, TX 77030 USA
来源
MODERN PROTEOMICS - SAMPLE PREPARATION, ANALYSIS AND PRACTICAL APPLICATIONS | 2016年 / 919卷
关键词
Mass spectrometer; Mass analyzer; Quadrupole mass analyzer; Ion trap mass analyzer; Time-of-flight (TOF) mass analyzer; FT-ICR mass analyzer; Orbitrap mass analyzer; Tandem mass analyzer; Triple quadrupoles tandem mass analyzer; Q-TOF tandem mass analyzer; TOF/TOF tandem mass analyzer; Product ion scan; Precursor ion scan; Neutral loss scan; Selected reaction monitoring; LASER-DESORPTION IONIZATION; COLLISION-INDUCED DISSOCIATION; ELECTROSPRAY-IONIZATION; LARGE BIOMOLECULES; QUADRUPOLE; PROTEINS; IDENTIFICATION; COMPLEXES; ORBITRAP; PRIMER;
D O I
10.1007/978-3-319-41448-5_7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometers are comprised of three main components: an ion source, a mass analyzer, and a detector. Ionization of the analyte occurs in the ion source and the resulting ions are counted at the detector. However, it is the mass analyzer that is responsible for determing the mass-to-charge ratio (m/z) of the ions (Jennings KR, Dolnikowski GG, Method Enzymol 193:37-61, 1990). Therefore, it is primarily the analyzer that allows the mass spectrometer to serve its primary goal-determining the mass of the analytes being measured. This becomes important in the field of molecular biology, where biomolecules may be of low molecular weight or often take on multiple charges (z) after ionization (Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM, Science 246:64-71, 1989). For this reason, the choice of analyzer is dependant on the properties of the analyte after ionization and the requirements of the experiment being performed.
引用
收藏
页码:157 / 169
页数:13
相关论文
共 50 条
  • [41] On Projective Connection of Optically Conjugate Points of Static Mass Analyzers
    Sachenko, V. D.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (14) : 1825 - 1831
  • [42] Calculation of the shape of the mass peaks of hyperboloid mass spectrometers with one-dimensional unipolar sorting of the ions
    Mamontov, EV
    Kiryushin, DV
    TECHNICAL PHYSICS, 1999, 44 (02) : 226 - 229
  • [43] Calculation of the shape of the mass peaks of hyperboloid mass spectrometers with one-dimensional unipolar sorting of the ions
    E. V. Mamontov
    D. V. Kiryushin
    Technical Physics, 1999, 44 : 226 - 229
  • [44] Surface modifications of stainless steel to minimise contamination in mass spectrometers
    Abda, J.
    Douce, D.
    Jones, G.
    Skeldon, P.
    Thompson, G. E.
    APPLIED SURFACE SCIENCE, 2015, 357 : 593 - 602
  • [45] A comparison of particle mass spectrometers during the 1999 Atlanta Supersite Project
    Middlebrook, AM
    Murphy, DM
    Lee, SH
    Thomson, DS
    Prather, KA
    Wenzel, RJ
    Liu, DY
    Phares, DJ
    Rhoads, KP
    Wexler, AS
    Johnston, MV
    Jimenez, JL
    Jayne, JT
    Worsnop, DR
    Yourshaw, I
    Seinfeld, JH
    Flagan, RC
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2003, 108 (D7)
  • [46] Standardized workflow for multiplexed charge detection mass spectrometry on orbitrap analyzers
    Su, Pei
    Mcgee, John P.
    Hollas, Michael A. R.
    Fellers, Ryan T.
    Durbin, Kenneth R.
    Greer, Joseph B.
    Early, Bryan P.
    Yip, Ping F.
    Zabrouskov, Vlad
    Srzentic, Kristina
    Senko, Michael W.
    Compton, Philip D.
    Kelleher, Neil L.
    Kafader, Jared O.
    NATURE PROTOCOLS, 2025,
  • [47] Experimental Characterization of Secular Frequency Scanning in Ion Trap Mass Spectrometers
    Snyder, Dalton T.
    Pulliam, Christopher J.
    Wiley, Joshua S.
    Duncan, Jason
    Cooks, R. Graham
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (07) : 1243 - 1255
  • [48] Direct sampling time-of-flight mass spectrometers for technological analysis
    Alexander A. Sysoev
    Alexey A. Sysoev
    S. S. Poteshin
    V. I. Pyatakhin
    I. V. Shchekina
    A. S. Trofimov
    Fresenius' Journal of Analytical Chemistry, 1998, 361 : 261 - 266
  • [49] High Energy Collisions on Tandem Time-of-Flight Mass Spectrometers
    Cotter, Robert J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (05) : 657 - 674
  • [50] Direct sampling time-of-flight mass spectrometers for technological analysis
    Sysoev, AA
    Sysoev, AA
    Poteshin, SS
    Pyatakhin, VI
    Shchekina, IV
    Trofimov, AS
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (03): : 261 - 266