Mass spectrometer; Mass analyzer; Quadrupole mass analyzer; Ion trap mass analyzer; Time-of-flight (TOF) mass analyzer; FT-ICR mass analyzer; Orbitrap mass analyzer; Tandem mass analyzer; Triple quadrupoles tandem mass analyzer; Q-TOF tandem mass analyzer; TOF/TOF tandem mass analyzer; Product ion scan; Precursor ion scan; Neutral loss scan; Selected reaction monitoring; LASER-DESORPTION IONIZATION; COLLISION-INDUCED DISSOCIATION; ELECTROSPRAY-IONIZATION; LARGE BIOMOLECULES; QUADRUPOLE; PROTEINS; IDENTIFICATION; COMPLEXES; ORBITRAP; PRIMER;
D O I
10.1007/978-3-319-41448-5_7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometers are comprised of three main components: an ion source, a mass analyzer, and a detector. Ionization of the analyte occurs in the ion source and the resulting ions are counted at the detector. However, it is the mass analyzer that is responsible for determing the mass-to-charge ratio (m/z) of the ions (Jennings KR, Dolnikowski GG, Method Enzymol 193:37-61, 1990). Therefore, it is primarily the analyzer that allows the mass spectrometer to serve its primary goal-determining the mass of the analytes being measured. This becomes important in the field of molecular biology, where biomolecules may be of low molecular weight or often take on multiple charges (z) after ionization (Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM, Science 246:64-71, 1989). For this reason, the choice of analyzer is dependant on the properties of the analyte after ionization and the requirements of the experiment being performed.
引用
收藏
页码:157 / 169
页数:13
相关论文
共 50 条
  • [31] Installation protocol for charge transfer dissociation mass spectrometry on ion trapping mass spectrometers
    Sasiene, Zachary J.
    Jackson, Glen P.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (12)
  • [32] Charge permutation reactions in beam type mass spectrometers
    Danell, AS
    Glish, GL
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2001, 212 (1-3) : 219 - 227
  • [33] Detection of Explosives: A Comparison of Analytical and Operational Characteristics of Mass Spectrometers and Ion Mobility Spectrometers
    T. I. Buryakov
    I. A. Buryakov
    Journal of Analytical Chemistry, 2025, 80 (3) : 411 - 422
  • [34] Beam distortions and their compensation in sector field mass spectrometers
    Yavor, MI
    Berdnikov, AS
    Wollnik, H
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1997, 171 (1-3) : 203 - 208
  • [35] The present and planned recoil mass spectrometers at Nuclear Science Centre, New Delhi
    S. Nath
    A. Jhingan
    T. Varughese
    J. J. Das
    P. Sugathan
    N. Madhavan
    R. Kumar
    R. P. Singh
    S. Muralithar
    R. K. Bhowmik
    A. K. Sinha
    Physics of Atomic Nuclei, 2003, 66 : 1523 - 1527
  • [36] Discovering Nature?s Fingerprints: Isotope Ratio Analysis on Bioanalytical Mass Spectrometers
    Neubauer, Cajetan
    Kantnerova, Kristyna
    Lamothe, Alexis
    Savarino, Joel
    Hilkert, Andreas
    Juchelka, Dieter
    Hinrichs, Kai-Uwe
    Elvert, Marcus
    Heuer, Verena
    Elsner, Martin
    Bakkour, Rani
    Julien, Maxime
    Oztoprak, Merve
    Schouten, Stefan
    Hattori, Shohei
    Dittmar, Thorsten
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2023, 34 (04) : 525 - 537
  • [37] Space-charge dynamics in Orbitrap mass spectrometers
    Grinfeld, D.
    Stewart, H.
    Skoblin, M.
    Denisov, E.
    Monastyrsky, M.
    Makarov, A.
    INTERNATIONAL JOURNAL OF MODERN PHYSICS A, 2019, 34 (36):
  • [38] Recent developments of miniature ion trap mass spectrometers
    Guo, Qi
    Gao, Lijuan
    Zhai, Yanbing
    Xu, Wei
    CHINESE CHEMICAL LETTERS, 2018, 29 (11) : 1578 - 1584
  • [39] Comparison of electron ionization mass spectra of some organic compounds (MW < 200 Da) recorded on mass spectrometers of various types
    Samokhin, A. S.
    Revel'skii, A. I.
    Revel'skii, I. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (14) : 1432 - 1436
  • [40] On Projective Connection of Optically Conjugate Points of Static Mass Analyzers
    V. D. Sachenko
    Journal of Analytical Chemistry, 2020, 75 : 1825 - 1831