Mass Analyzers and Mass Spectrometers

被引:41
作者
Haag, Anthony M. [1 ,2 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Texas Childrens Microbiome Ctr, Houston, TX 77030 USA
来源
MODERN PROTEOMICS - SAMPLE PREPARATION, ANALYSIS AND PRACTICAL APPLICATIONS | 2016年 / 919卷
关键词
Mass spectrometer; Mass analyzer; Quadrupole mass analyzer; Ion trap mass analyzer; Time-of-flight (TOF) mass analyzer; FT-ICR mass analyzer; Orbitrap mass analyzer; Tandem mass analyzer; Triple quadrupoles tandem mass analyzer; Q-TOF tandem mass analyzer; TOF/TOF tandem mass analyzer; Product ion scan; Precursor ion scan; Neutral loss scan; Selected reaction monitoring; LASER-DESORPTION IONIZATION; COLLISION-INDUCED DISSOCIATION; ELECTROSPRAY-IONIZATION; LARGE BIOMOLECULES; QUADRUPOLE; PROTEINS; IDENTIFICATION; COMPLEXES; ORBITRAP; PRIMER;
D O I
10.1007/978-3-319-41448-5_7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Mass spectrometers are comprised of three main components: an ion source, a mass analyzer, and a detector. Ionization of the analyte occurs in the ion source and the resulting ions are counted at the detector. However, it is the mass analyzer that is responsible for determing the mass-to-charge ratio (m/z) of the ions (Jennings KR, Dolnikowski GG, Method Enzymol 193:37-61, 1990). Therefore, it is primarily the analyzer that allows the mass spectrometer to serve its primary goal-determining the mass of the analytes being measured. This becomes important in the field of molecular biology, where biomolecules may be of low molecular weight or often take on multiple charges (z) after ionization (Fenn JB, Mann M, Meng CK, Wong SF, Whitehouse CM, Science 246:64-71, 1989). For this reason, the choice of analyzer is dependant on the properties of the analyte after ionization and the requirements of the experiment being performed.
引用
收藏
页码:157 / 169
页数:13
相关论文
共 50 条
  • [1] The physics and technology of quadrupole mass spectrometers
    Batey, Jonathan H.
    VACUUM, 2014, 101 : 410 - 415
  • [2] Towards Higher Sensitivity of Mass Spectrometry: A Perspective From the Mass Analyzers
    Li, Chang
    Chu, Shiying
    Tan, Siyuan
    Yin, Xinchi
    Jiang, You
    Dai, Xinhua
    Gong, Xiaoyun
    Fang, Xiang
    Tian, Di
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [3] Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
    El-Aneed, Anas
    Cohen, Aljandro
    Banoub, Joseph
    APPLIED SPECTROSCOPY REVIEWS, 2009, 44 (03) : 210 - 230
  • [4] Fast electrostatic sweep of a mass spectrum in permanent-magnet mass spectrometers
    O. N. Peregudov
    V. F. Shkurdoda
    L. F. Sukhodub
    Technical Physics, 2003, 48 : 128 - 130
  • [5] Fast electrostatic sweep of a mass spectrum in permanent-magnet mass spectrometers
    Peregudov, ON
    Shkurdoda, VF
    Sukhodub, LF
    TECHNICAL PHYSICS, 2003, 48 (01) : 128 - 130
  • [6] Combined cylindrical mass analyzers
    N. V. Astrakhantsev
    V. M. Bardakov
    Vo Nhu Dan
    G. N. Kichigin
    N. V. Lebedev
    N. A. Strokin
    Technical Physics, 2011, 56 : 1325 - 1332
  • [7] Combined Cylindrical Mass Analyzers
    Astrakhantsev, N. V.
    Bardakov, V. M.
    Dan, Vo Nhu
    Kichigin, G. N.
    Lebedev, N. V.
    Strokin, N. A.
    TECHNICAL PHYSICS, 2011, 56 (09) : 1325 - 1332
  • [8] Advances in microfabricated mass spectrometers
    Syms, R. R. A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (02) : 427 - 429
  • [9] Advances in microfabricated mass spectrometers
    R. R. A. Syms
    Analytical and Bioanalytical Chemistry, 2009, 393 : 427 - 429
  • [10] New approaches to miniaturizing ion trap mass analyzers
    Peng, Ying
    Austin, Daniel E.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (10) : 1560 - 1567