摘要
This prospective randomized pilot study sought to determine whether fixation with Sonoma CRx intramedullary pin is a comparable alternative to minimally invasive plating fixation in patients with displaced clavicle fractures. A total of 45 consecutive patients (Robinson class B1 or B2) were randomly allocated into two groups; intramedullary pin (IMP) group (n = 24, mean age; 33.17 +/- A 8.60 years, 14 males 58.3 %) received Sonoma CRx Collarbone pin (Sonoma, USA) whereas locking midshaft superior plating (MIPPO) group (n = 21, 32.38 +/- A 8.41 years, 12 males) patients received minimally invasive locking midshaft superior plating (Acumed, USA). Patients were followed up with a mean time of 11.82 +/- A 4.22 and 14.45 +/- A 6.43 months, respectively. Functional status, as the primary outcome measure, was assessed using quick disability of the arm, shoulder and hand (DASH) scores. Mean time of operation and mean time of fluoroscopy were significantly shorter in the IMP group than those in MIPPO group (p < 0.001 and p = 0.03, respectively). Time of hospital stay was significantly shorter in IMP group (p < 0.001). Complications were rare in the early postoperative period. Time until bony union was significantly shorter in IMP group. Mean quick DASH scores were not significantly different between two groups. Implant failure occurred in one patient from each group. Cosmetic dissatisfaction was more common in MIPPO group. Given the shorter operative times and better cosmetic appearance, Sonoma CRx intramedullary pin may be an alternative to minimally invasive plating. Further safety studies are warranted.
引用
收藏
页码:339 / 344
页数:6
相关论文
共 50 条
  • [21] Intramedullary screw fixation for midshaft fractures of the clavicle
    Ayman Khalil
    International Orthopaedics, 2009, 33 : 1421 - 1424
  • [22] Intramedullary Screw Fixation for Midshaft Clavicle Fractures
    Bents, Robert Thurston
    Bents, Easton James
    ARTHROSCOPY TECHNIQUES, 2024, 13 (03):
  • [23] Plating versus elastic stable intramedullary nailing for displaced pediatric midshaft clavicular fractures
    Pan Hong
    Ruikang Liu
    Saroj Rai
    Renhao Ze
    Xin Tang
    Jin Li
    Journal of Orthopaedics and Traumatology, 2022, 23
  • [24] Titanium elastic stable intramedullary nailing of displaced midshaft clavicle fractures: A review of 38 cases
    Kadakia, Anish P.
    Rambani, Rohit
    Qamar, Faisal
    McCoy, Steven
    Koch, Lutz
    Venkateswaran, Balachandran
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2012, 6 (03): : 82 - 85
  • [25] Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison
    Wijdicks, Frans-Jasper
    Houwert, Marijn
    Dijkgraaf, Marcel
    de lange, Diederik
    Oosterhuis, Koen
    Clevers, Geertjan
    Verleisdonk, Egbert-Jan
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (10) : 2139 - 2145
  • [26] In Completely Displaced Midshaft Fractures of the Clavicle, Plate Fixation and Elastic Stable Intramedullary Nailing Did Not Differ in Function at One Year
    Ricci, William M.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (10): : 883 - 883
  • [27] Complications after plate fixation and elastic stable intramedullary nailing of dislocated midshaft clavicle fractures: a retrospective comparison
    Frans-Jasper Wijdicks
    Marijn Houwert
    Marcel Dijkgraaf
    Diederik de Lange
    Koen Oosterhuis
    Geertjan Clevers
    Egbert-Jan Verleisdonk
    International Orthopaedics, 2012, 36 : 2139 - 2145
  • [28] Plate fixation of fresh displaced midshaft clavicle fractures
    Shen, WJ
    Liu, TJ
    Shen, YS
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1999, 30 (07): : 497 - 500
  • [29] Intramedullary nailing of dislocated midshaft clavicle fractures with the Rockwood Clavicle Pin, a retrospective study
    Nordenstedt, Bjorn
    von Heideken, Johan
    Windhamre, Helena Bostrom
    Stauffer, Maria
    Ekelund, Anders
    ACTA ORTHOPAEDICA BELGICA, 2019, 85 (04): : 412 - 420
  • [30] Excessive Complications of Open Intramedullary Nailing of Midshaft Clavicle Fractures With the Rockwood Clavicle Pin
    Mudd, Christopher D.
    Quigley, Kevin J.
    Gross, Lyndon B.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) : 3364 - 3370