Cyclic fatigue of ProTaper rotary nickel-titanium instruments in artificial canals with 2 different radii of curvature

被引:39
作者
Inan, Ugur [1 ]
Aydin, Cumhur [1 ]
Tunca, Yasar M. [1 ]
机构
[1] Ondokuz Mayis Univ, Fac Dent, Dept Restorat Dent & Endodont, TR-55139 Kurupelit, Turkey
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY | 2007年 / 104卷 / 06期
关键词
D O I
10.1016/j.tripleo.2007.06.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective. This study compared the cyclic fatigue resistance of ProTaper rotary nickel-titanium (NiTi) files in artificial canals with 2 different radii of curvature. Study design. One hundred ProTaper rotary instruments were used in this study. Twenty files of each size (S1, S2, F1, F2, and F3) were tested. Cyclic fatigue testing was performed using a device that allowed the instruments to rotate freely inside stainless steel artificial canals with radii of curvature of 5 and 10 mm. The number of cycles to fracture was recorded for each file and the data were analyzed using a t-test. Results. The 5-mm radius group had significantly fewer cycles to fracture than the 10-mm radius group for all file sizes. For sizes F2 and F3, the difference between the 5 and 10-mm radius groups was highly significant (P < .001). For the 10-mm group, the difference between S1 and F3 was significant (P < .05). For the more abrupt 5-mm radius group, the difference between S1-F2, S2-F2, and F1-F2 was statistically significant. The difference between S1-F3, S2-F3, and F1-F3 was highly significant (P < .001). Conclusion. Cyclic fatigue resistance of ProTaper instruments was dependent on both instrument size and radius of curvature. Especially larger-size instruments should be used with great care in curved canals.
引用
收藏
页码:837 / 840
页数:4
相关论文
共 19 条
  • [1] K3 endo, ProTaper, and ProFile systems: Breakage and distortion, in severely curved roots of molars
    Ankrum, MT
    Hartwell, GR
    Truitt, JE
    [J]. JOURNAL OF ENDODONTICS, 2004, 30 (04) : 234 - 237
  • [2] Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals
    Bahia, MGA
    Buono, VTL
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (02): : 249 - 255
  • [3] Clauder Thomas, 2004, Dent Clin North Am, V48, P87, DOI 10.1016/j.cden.2003.10.006
  • [4] Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use
    Fife, D
    Gambarini, G
    Britto, LR
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2004, 97 (02): : 251 - 256
  • [5] Fishelberg Gerald, 2004, Compend Contin Educ Dent, V25, P17
  • [6] Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors
    Gambarini, G
    [J]. JOURNAL OF ENDODONTICS, 2001, 27 (12) : 772 - 774
  • [7] Gambarini G, 2000, ENDOD DENT TRAUMATOL, V16, P95
  • [8] Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems
    Grande, N. M.
    Plotino, G.
    Pecci, R.
    Bedini, R.
    Malagnino, V. A.
    Somma, F.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (10) : 755 - 763
  • [9] Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    Haïkel, Y
    Serfaty, R
    Bateman, G
    Senger, B
    Allemann, C
    [J]. JOURNAL OF ENDODONTICS, 1999, 25 (06) : 434 - 440
  • [10] Factors influencing the fracture of nickel-titanium rotary instruments
    Martín, B
    Zelada, G
    Varela, P
    Bahillo, JG
    Magán, F
    Ahn, S
    Rodríguez, C
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2003, 36 (04) : 262 - 266