Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode

被引:8
|
作者
Nhi, Le Thi Thanh [1 ,2 ,3 ]
Tu, Nguyen Thi Thanh [4 ]
Hoa, Le Thi [3 ]
Toan, Tran Thanh Tam [5 ]
Van Thanh Son, Le [6 ]
Van Hung, Nguyen [7 ]
Tuyen, Tran Ngoc [3 ]
Khieu, Dinh Quang [3 ]
机构
[1] Duy Tan Univ, Inst Res & Dev, Ctr Adv Chem, Da Nang 550000, Vietnam
[2] Duy Tan Univ, Fac Nat Sci, Da Nang 550000, Vietnam
[3] Hue Univ, Univ Sci, Hue 530000, Vietnam
[4] Van Lang Univ, Fac Technol, Ho Chi Minh City 700000, Vietnam
[5] Dong A Univ, Da Nang 550000, Vietnam
[6] Univ Danang, Univ Educ & Sci, Da Nang 550000, Vietnam
[7] Dong Thap Univ, Cao Lanh 870000, Vietnam
关键词
Paracetamol; Ascorbic acid; Simultaneous determination; UiO-66; Nanostructures; Nanocomposite materials; METAL-ORGANIC FRAMEWORKS; ELECTROCHEMICAL DETERMINATION; GASEOUS TOLUENE; PARACETAMOL; UIO-66; PERFORMANCE; OXIDATION;
D O I
10.1007/s11051-021-05327-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article reports the synthesis of the University of Oslo-66 (UiO-66) and its application to simultaneous voltammetric determination of ascorbic acid (AA) and acetaminophen (AC). The zirconium terephthalate samples synthesized in different solvents (the N,N '-dimethylformamide, acetonitrile, and ethanol) are characterized with XRD, SEM, TG, nitrogen adsorption/desorption isotherm, and XPS techniques. Among solvents the N,N '-dimethylformamide solvent is favorable for the UiO-66 phase formation. The synthesized UiO-66 material with spherical particles with round 100-150 nm in diameters possesses a large specific surface area. The UiO-66 is used as electrode modifier to develop UiO-66 modified glassy carbon electrode for determining simultaneous AA and AC. The UiO-66 modified electrode demonstrates excellent electrocatalytic performance towards AA and AC oxidation compared with bare GCE. The anodic peak current varies linearly to AA and AC concentration in the range of 0.02 to 2.92 mu M. The level of detection (S/N = 3) was found to be 0.019 and 0.018 mu M, respectively. The proposed differential pulse voltammetry method was used to determine individually or simultaneously AA and AC in pharmaceutical formulations. The results are not significant different from those analyzed by high-performance liquid chromatography.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Simultaneous voltammetric determination of acetaminophen and dopamine using a glassy carbon electrode modified with copper porphyrin-exfoliated graphene
    Song, Xinjian
    Fu, Ju
    Wang, Juan
    Li, Chunya
    Liu, Zhihong
    MICROCHIMICA ACTA, 2018, 185 (08)
  • [42] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502
  • [43] Differential pulse voltammetric simultaneous determination of ascorbic acid, dopamine and uric acid on a glassy carbon electrode modified with electroreduced graphene oxide and imidazolium groups
    Wu, Feng
    Huang, Ting
    Hu, Yangjian
    Yang, Xin
    Ouyang, Yuejun
    Xie, Qingji
    MICROCHIMICA ACTA, 2016, 183 (09) : 2539 - 2546
  • [44] Voltammetric determination of acetaminophen in pharmaceutical preparations and human urine using glassy carbon paste electrode modified with reduced graphene oxide
    Farag, Amir Shaaban
    ANALYTICAL SCIENCES, 2022, 38 (09) : 1213 - 1220
  • [45] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    Chen, Meifeng
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (02) : 154 - 161
  • [46] Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid by Differential Pulse Voltammetry using Tiron Modified Glassy Carbon Electrode
    Ensafi, Ali A.
    Taei, M.
    Khayamian, Taghi
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (01): : 116 - 130
  • [47] Highly selective and sensitive voltammetric sensor based on modified multiwall carbon nanotube paste electrode for simultaneous determination of ascorbic acid, acetaminophen and tryptophan
    Keyvanfard, Mohsen
    Shakeri, Razieh
    Karimi-Maleh, Hassan
    Alizad, Khadijeh
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (02): : 811 - 816
  • [48] Simultaneous determination of ascorbic acid, acetaminophen and codeine based on multi-walled carbon nanotubes modified with magnetic nanoparticles paste electrode
    Taei, M.
    Salavati, H.
    Hasanpour, F.
    Habibollahi, S.
    Baghlani, H.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 1 - 11
  • [49] Chitosan incorporating cetyltrimethylammonium bromide modified glassy carbon electrode for simultaneous determination of ascorbic acid and dopamine
    Zou, Xuelian
    Luo, Liqiang
    Ding, Yaping
    Wu, Qingsheng
    ELECTROANALYSIS, 2007, 19 (17) : 1840 - 1844
  • [50] SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PARACETAMOL AND ASCORBIC ACID USING ACTIVATED GLASSY CARBON ELECTRODE: CYCLIC VOLTAMMETRY AND SQUARE WAVE VOLTAMMETRY STUDY
    Shewarega, Yared
    Yenealem, Dereje
    Siyum, Fikadu
    ACTA CHEMICA IASI, 2021, 29 (02) : 107 - 122