Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode

被引:8
|
作者
Nhi, Le Thi Thanh [1 ,2 ,3 ]
Tu, Nguyen Thi Thanh [4 ]
Hoa, Le Thi [3 ]
Toan, Tran Thanh Tam [5 ]
Van Thanh Son, Le [6 ]
Van Hung, Nguyen [7 ]
Tuyen, Tran Ngoc [3 ]
Khieu, Dinh Quang [3 ]
机构
[1] Duy Tan Univ, Inst Res & Dev, Ctr Adv Chem, Da Nang 550000, Vietnam
[2] Duy Tan Univ, Fac Nat Sci, Da Nang 550000, Vietnam
[3] Hue Univ, Univ Sci, Hue 530000, Vietnam
[4] Van Lang Univ, Fac Technol, Ho Chi Minh City 700000, Vietnam
[5] Dong A Univ, Da Nang 550000, Vietnam
[6] Univ Danang, Univ Educ & Sci, Da Nang 550000, Vietnam
[7] Dong Thap Univ, Cao Lanh 870000, Vietnam
关键词
Paracetamol; Ascorbic acid; Simultaneous determination; UiO-66; Nanostructures; Nanocomposite materials; METAL-ORGANIC FRAMEWORKS; ELECTROCHEMICAL DETERMINATION; GASEOUS TOLUENE; PARACETAMOL; UIO-66; PERFORMANCE; OXIDATION;
D O I
10.1007/s11051-021-05327-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article reports the synthesis of the University of Oslo-66 (UiO-66) and its application to simultaneous voltammetric determination of ascorbic acid (AA) and acetaminophen (AC). The zirconium terephthalate samples synthesized in different solvents (the N,N '-dimethylformamide, acetonitrile, and ethanol) are characterized with XRD, SEM, TG, nitrogen adsorption/desorption isotherm, and XPS techniques. Among solvents the N,N '-dimethylformamide solvent is favorable for the UiO-66 phase formation. The synthesized UiO-66 material with spherical particles with round 100-150 nm in diameters possesses a large specific surface area. The UiO-66 is used as electrode modifier to develop UiO-66 modified glassy carbon electrode for determining simultaneous AA and AC. The UiO-66 modified electrode demonstrates excellent electrocatalytic performance towards AA and AC oxidation compared with bare GCE. The anodic peak current varies linearly to AA and AC concentration in the range of 0.02 to 2.92 mu M. The level of detection (S/N = 3) was found to be 0.019 and 0.018 mu M, respectively. The proposed differential pulse voltammetry method was used to determine individually or simultaneously AA and AC in pharmaceutical formulations. The results are not significant different from those analyzed by high-performance liquid chromatography.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Voltammetric determination of chlorogenic acid in pharmaceutical products using poly(aminosulfonic acid) modified glassy carbon electrode
    Chao, Mingyong
    Ma, Xinying
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (04) : 512 - 519
  • [32] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [33] Development of a Glassy Carbon Electrode Modified with Graphene/Au Nanoparticles for Determination of Acetaminophen in Pharmaceutical Preparation
    Wei, Yingliang
    Wang, Anting
    Liu, Yuanyuan
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2018, 54 (12) : 1141 - 1147
  • [34] Room Temperature Ionic Liquid/Multiwalled Carbon Nanotube/Chitosan-Modified Glassy Carbon Electrode as a Sensor for Simultaneous Determination of Ascorbic Acid, Uric Acid, Acetaminophen, and Mefenamic Acid
    Kianipour, Shokat
    Asghari, Alireza
    IEEE SENSORS JOURNAL, 2013, 13 (07) : 2690 - 2698
  • [35] Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode
    Cao, Xiaomei
    Xu, Yanhong
    Luo, Liqiang
    Ding, Yaping
    Zhang, Ying
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (05) : 829 - 834
  • [36] Modification of carbon paste electrode with Fe(III)-clinoptilolite nano-particles for simultaneous voltammetric determination of acetaminophen and ascorbic acid
    Sharifian, Samira
    Nezamzadeh-Ejhieh, Alireza
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 510 - 520
  • [37] Voltammetric Determination of Ascorbic Acid in Pharmaceutical Formulations on a Boron Doped Diamond Electrode
    M. D. Vedenyapina
    M. M. Kazakova
    A. M. Skundin
    Russian Journal of Physical Chemistry A, 2019, 93 : 1178 - 1181
  • [38] Determination of Acetaminophen (Paracetamol) by Tranexamic Acid Modified Glassy Carbon Electrode
    Islamoglu, Nesim
    Muelazimoglu, Aysen Demir
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (12): : 1086 - 1097
  • [39] Multi-walled Carbon Nanotubes/Graphite Nanosheets Modified Glassy Carbon Electrode for the Simultaneous Determination of Acetaminophen and Dopamine
    Zhang, Susu
    He, Ping
    Zhang, Guangli
    Lei, Wen
    He, Huichao
    ANALYTICAL SCIENCES, 2015, 31 (07) : 657 - 662
  • [40] Easy modification of glassy carbon electrode for simultaneous determination of ascorbic acid, dopamine and uric acid
    Thiagarajan, Soundappan
    Tsai, Tsung-Hsuan
    Chen, Shen-Ming
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) : 2712 - 2715