Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode

被引:8
|
作者
Nhi, Le Thi Thanh [1 ,2 ,3 ]
Tu, Nguyen Thi Thanh [4 ]
Hoa, Le Thi [3 ]
Toan, Tran Thanh Tam [5 ]
Van Thanh Son, Le [6 ]
Van Hung, Nguyen [7 ]
Tuyen, Tran Ngoc [3 ]
Khieu, Dinh Quang [3 ]
机构
[1] Duy Tan Univ, Inst Res & Dev, Ctr Adv Chem, Da Nang 550000, Vietnam
[2] Duy Tan Univ, Fac Nat Sci, Da Nang 550000, Vietnam
[3] Hue Univ, Univ Sci, Hue 530000, Vietnam
[4] Van Lang Univ, Fac Technol, Ho Chi Minh City 700000, Vietnam
[5] Dong A Univ, Da Nang 550000, Vietnam
[6] Univ Danang, Univ Educ & Sci, Da Nang 550000, Vietnam
[7] Dong Thap Univ, Cao Lanh 870000, Vietnam
关键词
Paracetamol; Ascorbic acid; Simultaneous determination; UiO-66; Nanostructures; Nanocomposite materials; METAL-ORGANIC FRAMEWORKS; ELECTROCHEMICAL DETERMINATION; GASEOUS TOLUENE; PARACETAMOL; UIO-66; PERFORMANCE; OXIDATION;
D O I
10.1007/s11051-021-05327-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article reports the synthesis of the University of Oslo-66 (UiO-66) and its application to simultaneous voltammetric determination of ascorbic acid (AA) and acetaminophen (AC). The zirconium terephthalate samples synthesized in different solvents (the N,N '-dimethylformamide, acetonitrile, and ethanol) are characterized with XRD, SEM, TG, nitrogen adsorption/desorption isotherm, and XPS techniques. Among solvents the N,N '-dimethylformamide solvent is favorable for the UiO-66 phase formation. The synthesized UiO-66 material with spherical particles with round 100-150 nm in diameters possesses a large specific surface area. The UiO-66 is used as electrode modifier to develop UiO-66 modified glassy carbon electrode for determining simultaneous AA and AC. The UiO-66 modified electrode demonstrates excellent electrocatalytic performance towards AA and AC oxidation compared with bare GCE. The anodic peak current varies linearly to AA and AC concentration in the range of 0.02 to 2.92 mu M. The level of detection (S/N = 3) was found to be 0.019 and 0.018 mu M, respectively. The proposed differential pulse voltammetry method was used to determine individually or simultaneously AA and AC in pharmaceutical formulations. The results are not significant different from those analyzed by high-performance liquid chromatography.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Voltammetric studies of an oracet blue modified glassy carbon electrode and its application for the simultaneous determination of dopamine, ascorbic acid and uric acid
    Zare, HR
    Rajabzadeh, N
    Nasirizadeh, N
    Mazloum-Ardakani, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2006, 589 (01) : 60 - 69
  • [22] Docosyltrimethylammonium chloride modified glassy carbon electrode for simultaneous determination of dopamine and ascorbic acid
    Li-Qiang Luo
    Qiu-Xia Li
    Ya-Ping Ding
    Ying Zhang
    Xia Shen
    Journal of Solid State Electrochemistry, 2010, 14 : 1311 - 1316
  • [23] Simultaneous determination of tyrosine, acetaminophen and ascorbic acid using gold nanoparticles/multiwalled carbon nanotube/glassy carbon electrode by differential pulse voltammetric method
    Madrakian, Tayyebeh
    Haghshenas, Esmaeel
    Afkhami, Abbas
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 451 - 460
  • [24] Simultaneous Differential Pulse Voltammetric Determination of Ascorbic Acid and Caffeine in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2010, 22 (15) : 1717 - 1723
  • [25] Modified Glassy Carbon Electrode with Polypyrrole Nanocomposite for the Simultaneous Determination of Ascorbic acid, Dopamine, Uric acid, and Folic Acid
    Ghanbari, Khadijeh
    Bonyadi, Sepideh
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND TECHNOLOGY, 2020, 11 (01) : 68 - 83
  • [26] Voltammetric sensor for simultaneous determination of ascorbic acid, acetaminophen, and tryptophan in pharmaceutical products
    Beitollahi, Hadi
    Mohadesi, Alireza
    Mostafavi, Mortaza
    Karimi-Maleh, Hassan
    Baghayeri, Mehdi
    Akbari, Ali
    IONICS, 2014, 20 (05) : 729 - 737
  • [27] Graphene/Nafion composite film modified glassy carbon electrode for simultaneous determination of paracetamol, aspirin and caffeine in pharmaceutical formulations
    Yigit, Aydin
    Yardim, Yavuz
    Celebi, Metin
    Levent, Abdulkadir
    Senturk, Zuhre
    TALANTA, 2016, 158 : 21 - 29
  • [28] Simultaneous Determination of Dopamine, Serotonin and Ascorbic Acid at a Glassy Carbon Electrode Modified with Carbon-Spheres
    Zhou, Jianqing
    Sheng, Meili
    Jiang, Xueyue
    Wu, Guozhi
    Gao, Feng
    SENSORS, 2013, 13 (10): : 14029 - 14040
  • [29] Voltammetric sensor for simultaneous determination of ascorbic acid, acetaminophen, and tryptophan in pharmaceutical products
    Hadi Beitollahi
    Alireza Mohadesi
    Mortaza Mostafavi
    Hassan Karimi-Maleh
    Mehdi Baghayeri
    Ali Akbari
    Ionics, 2014, 20 : 729 - 737
  • [30] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) : 1086 - 1092