Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode

被引:8
|
作者
Nhi, Le Thi Thanh [1 ,2 ,3 ]
Tu, Nguyen Thi Thanh [4 ]
Hoa, Le Thi [3 ]
Toan, Tran Thanh Tam [5 ]
Van Thanh Son, Le [6 ]
Van Hung, Nguyen [7 ]
Tuyen, Tran Ngoc [3 ]
Khieu, Dinh Quang [3 ]
机构
[1] Duy Tan Univ, Inst Res & Dev, Ctr Adv Chem, Da Nang 550000, Vietnam
[2] Duy Tan Univ, Fac Nat Sci, Da Nang 550000, Vietnam
[3] Hue Univ, Univ Sci, Hue 530000, Vietnam
[4] Van Lang Univ, Fac Technol, Ho Chi Minh City 700000, Vietnam
[5] Dong A Univ, Da Nang 550000, Vietnam
[6] Univ Danang, Univ Educ & Sci, Da Nang 550000, Vietnam
[7] Dong Thap Univ, Cao Lanh 870000, Vietnam
关键词
Paracetamol; Ascorbic acid; Simultaneous determination; UiO-66; Nanostructures; Nanocomposite materials; METAL-ORGANIC FRAMEWORKS; ELECTROCHEMICAL DETERMINATION; GASEOUS TOLUENE; PARACETAMOL; UIO-66; PERFORMANCE; OXIDATION;
D O I
10.1007/s11051-021-05327-w
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This article reports the synthesis of the University of Oslo-66 (UiO-66) and its application to simultaneous voltammetric determination of ascorbic acid (AA) and acetaminophen (AC). The zirconium terephthalate samples synthesized in different solvents (the N,N '-dimethylformamide, acetonitrile, and ethanol) are characterized with XRD, SEM, TG, nitrogen adsorption/desorption isotherm, and XPS techniques. Among solvents the N,N '-dimethylformamide solvent is favorable for the UiO-66 phase formation. The synthesized UiO-66 material with spherical particles with round 100-150 nm in diameters possesses a large specific surface area. The UiO-66 is used as electrode modifier to develop UiO-66 modified glassy carbon electrode for determining simultaneous AA and AC. The UiO-66 modified electrode demonstrates excellent electrocatalytic performance towards AA and AC oxidation compared with bare GCE. The anodic peak current varies linearly to AA and AC concentration in the range of 0.02 to 2.92 mu M. The level of detection (S/N = 3) was found to be 0.019 and 0.018 mu M, respectively. The proposed differential pulse voltammetry method was used to determine individually or simultaneously AA and AC in pharmaceutical formulations. The results are not significant different from those analyzed by high-performance liquid chromatography.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Simultaneous voltammetric determination of ascorbic acid and acetaminophen in pharmaceutical formulations with UiO-66-modified glassy carbon electrode
    Le Thi Thanh Nhi
    Nguyen Thi Thanh Tu
    Le Thi Hoa
    Tran Thanh Tam Toan
    Le Van Thanh Son
    Nguyen Van Hung
    Tran Ngoc Tuyen
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2021, 23
  • [2] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Manh, Tran Duc
    Nguyen, Vo Thang
    Duyen, Vu Thi
    Nga, Nguyen Thi Thy
    Man, Nguyen Quang
    Thoa, Pham Thi Huyen
    Trinh, Le Huu
    Khieu, Dinh Quang
    JOURNAL OF NANOPARTICLE RESEARCH, 2023, 25 (09)
  • [3] Differential pulse voltammetry determination of acetaminophen and codeine in pharmaceutical formulations using a Mn/UiO-66 modified glassy carbon electrode
    Tran Duc Manh
    Vo Thang Nguyen
    Vu Thi Duyen
    Nguyen Thi Thy Nga
    Nguyen Quang Man
    Pham Thi Huyen Thoa
    Le Huu Trinh
    Dinh Quang Khieu
    Journal of Nanoparticle Research, 2023, 25
  • [4] A new sensor based on glassy carbon electrode modified with nanocomposite for simultaneous determination of acetaminophen, ascorbic acid and uric acid
    Afrasiabi, Mohammad
    Kianipour, Shokat
    Babaei, Ali
    Nasimi, Ali Asghar
    Shabanian, Meisam
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2016, 20 : S480 - S487
  • [5] Simultaneous voltammetric determination of tramadol and acetaminophen using carbon nanoparticles modified glassy carbon electrode
    Ghorbani-Bidkorbeh, Fatemeh
    Shahrokhian, Saeed
    Mohammadi, Ali
    Dinarvand, Rassoul
    ELECTROCHIMICA ACTA, 2010, 55 (08) : 2752 - 2759
  • [6] Simultaneous voltammetric determination of norepinephrine, ascorbic acid and uric acid on polycalconcarboxylic acid modified glassy carbon electrode
    Liu, Ai-Lin
    Zhang, Shao-Bo
    Chen, Wei
    Lin, Xin-Hua
    Xia, Xing-Hua
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (10) : 1488 - 1495
  • [7] Docosyltrimethylammonium chloride modified glassy carbon electrode for simultaneous determination of dopamine and ascorbic acid
    Luo, Li-Qiang
    Li, Qiu-Xia
    Ding, Ya-Ping
    Zhang, Ying
    Shen, Xia
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (07) : 1311 - 1316
  • [8] Au nanoparticles/poly(caffeic acid) composite modified glassy carbon electrode for voltammetric determination of acetaminophen
    Li, Tianbao
    Xu, Juan
    Zhao, Lei
    Shen, Shaofei
    Yuan, Maosen
    Liu, Wenming
    Tu, Qin
    Yu, Ruijin
    Wang, Jinyi
    TALANTA, 2016, 159 : 356 - 364
  • [9] Simultaneous voltammetric measurement of ascorbic acid and dopamine on poly(caffeic acid)-modified glassy carbon electrode
    Nian Bing Li
    Wang Ren
    Hong Qun Luo
    Journal of Solid State Electrochemistry, 2008, 12 : 693 - 699
  • [10] Multiwall carbon nanotube modified glassy carbon electrode as voltammetric sensor for the simultaneous determination of ascorbic acid and caffeine
    Gupta, Vinod Kumar
    Jain, Ajay Kumar
    Shoora, Sudhir Kumar
    ELECTROCHIMICA ACTA, 2013, 93 : 248 - 253