Time-resolved non-contact fluorescence diffuse optical tomography measurements with ultra-fast time-correlated single photon counting avalanche photodiodes

被引:1
|
作者
Berube-Lauziere, Yves [1 ]
Robichaud, Vincent [1 ]
Lapointe, Eric [1 ]
机构
[1] Univ Sherbrooke, Dept Genie Elect & Genie Informat, Lab TomOptUs, 2500 Boul Univ, Sherbrooke, PQ J1K 2R1, Canada
来源
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
diffuse optical tomography; avalanche photodiodes; time-correlated single photon counting; fluorescence; time-resolved optical measurements; time point-spread functions; photomultiplier tubes; non-contact measurements; time-domain;
D O I
10.1117/12.729388
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The design and fabrication of time-correlated single photon counting (TCSPC) avalanche photodiodes (APDs) and associated quenching circuits have made significant progresses in recent years. APDs with temporal resolutions comparable to microchannel plate photomultiplier tubes (MCP-PMTs) are now available, MCP-PMTs were until these progresses the best TCSPC detectors with timing resolutions down to 30ps. APDs can now achieve these resolutions at a fraction of the cost. Work is under way to make the manufacturing of TCSPC APDs compatible with standard electronics fabrication practices. This should allow to further reduce their cost and render them easier to integrate in complex multi-channel TCSPC electronics, as needed in diffuse optical tomography (DOT) systems. Even if their sensitive area is much smaller than that of the ubiquitous PMT used in TCSPC, we show that with appropriate selection of optical components, TCSPC APDs can be used in time-domain DOT. To support this, we present experimental data and calculations clearly demonstrating that comparable measurements can be obtained with APDs and PMTs. We are, to our knowledge, the first group using APDs in TD DOT, in particular in non-contact TD fluorescence DOT.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Fast calculation of fluorescence correlation data with asynchronous time-correlated single-photon counting
    Wahl, M
    Gregor, I
    Patting, M
    Enderlein, J
    OPTICS EXPRESS, 2003, 11 (26): : 3583 - 3591
  • [22] Toward ultra-fast time-correlated single-photon counting: A compact module to surpass the pile-up limit
    Farina, S.
    Acconcia, G.
    Labanca, I
    Ghioni, M.
    Rech, I
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (06):
  • [23] FLUORESCENCE LIFETIME MEASUREMENTS UNDER A MICROSCOPE BY THE TIME-CORRELATED SINGLE-PHOTON COUNTING TECHNIQUE
    MINAMI, T
    KAWAHIGASHI, M
    SAKAI, Y
    SHIMAMOTO, K
    HIRAYAMA, S
    JOURNAL OF LUMINESCENCE, 1986, 35 (05) : 247 - 253
  • [24] Fast time-correlated single photon counting system to overcome pile-up limitation with single photon avalanche diodes
    Farina, Serena
    Acconcia, Giulia
    Labanca, Ivan
    Ghioni, Massimo
    Rech, Ivan
    ADVANCED PHOTON COUNTING TECHNIQUES XV, 2021, 11721
  • [25] Single-Photon Avalanche Diode CMOS Sensor for Time-Resolved Fluorescence Measurements
    Stoppa, David
    Mosconi, Daniel
    Pancheri, Lucio
    Gonzo, Lorenzo
    IEEE SENSORS JOURNAL, 2009, 9 (09) : 1084 - 1090
  • [26] FLUORESCENCE SPECTROSCOPY THROUGH AN OPTICAL FIBER WITH A TIME-CORRELATED SINGLE-PHOTON COUNTING METHOD
    KUSHIDA, T
    WATANABE, J
    KINOSHITA, S
    JOURNAL OF LUMINESCENCE, 1984, 31-2 (DEC) : 718 - 720
  • [27] Non-contact characterization of bacteria by time-resolved fluorescence
    Bouchard, A
    Fréchette, J
    Long, WF
    Vernon, M
    Cormier, JF
    Vallée, R
    Mafu, AA
    Lemay, MJ
    BIOMEDICAL VIBRATIONAL SPECTROSCOPY AND BIOHAZARD DETECTION TECHNOLOGIES, 2004, 5321 : 250 - 257
  • [28] Monolithic Time-to-Digital Converter chips for Time-Correlated Single-Photon Counting and Fluorescence Lifetime measurements
    Markovic, Bojan
    Tamborini, Davide
    Bellisai, Simone
    Bassi, Andrea
    Pifferi, Antonio
    Villa, Federica
    Padovini, Giorgio Michele
    Tosi, Alberto
    QUANTUM SENSING AND NANOPHOTONIC DEVICES X, 2013, 8631
  • [29] Fluorescence diffuse optical tomography by full time-resolved scheme
    Gao, Feng
    Miao, Hui
    Zhao, Huijuan
    Tanikawa, Yukari
    Yamada, Yukio
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [30] Comparison of two time-resolved detectors for diffuse optical tomography: photomultiplier tube-time-correlated single photon counting and multi-channel streak camera
    Poulet, P
    Zint, CV
    Torregrossa, M
    Uhring, W
    Cunin, B
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE V, 2003, 4955 : 154 - 163