Comparison of 4D Flow MRI and Particle Image Velocimetry Using an In Vitro Carotid Bifurcation Model

被引:19
作者
Medero, Rafael [1 ,4 ,5 ]
Hoffman, Carson [2 ]
Roldan-Alzate, Alejandro [1 ,3 ,4 ]
机构
[1] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI USA
[4] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[5] 1415 Engn Dr, Madison, WI 53706 USA
关键词
4D flow MRI; Experimental validation; Tomographic PIV; Stereoscopic PIV; Hemodynamics; PHASE-CONTRAST MRI; VENOUS HEMODYNAMICS; SELF-CALIBRATION; BLOOD-FLOW; VELOCITY; VALIDATION; ULTRASOUND; VIVO; 2D; VISUALIZATION;
D O I
10.1007/s10439-018-02109-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Four-dimensional (4D) Flow magnetic resonance imaging (MRI) enables the acquisition and assessment of complex hemodynamics in vivo from different vascular territories. This study investigated the viability of stereoscopic and tomographic particle image velocimetry (stereo- and tomo-PIV, respectively) as experimental validation techniques for 4D Flow MRI. The experiments were performed using continuous and pulsatile flows through an idealized carotid artery bifurcation model. Transverse and longitudinal planes were extracted from the acquired velocity data sets at different regions of interest and were analyzed with a point-by-point comparison. An overall root-mean-square error (RMSE) was calculated resulting in errors as low as 0.06 and 0.03m/s when comparing 4D Flow MRI with stereo- and tomo-PIV, respectively. Quantitative agreement between techniques was determined by evaluating the relationship for individual velocity components and their magnitudes. These resulted in correlation coefficients (R-2) of 4D Flow MRI with stereo- and tomo-PIV, as low as 0.76 and 0.73, respectively. The 3D velocity measurements from PIV showed qualitative agreement when compared to 4D Flow MRI, especially with tomo-PIV due to the addition of volumetric velocity measurements. These results suggest that tomo-PIV can be used as a validation technique for 4D Flow MRI, serving as the basis for future validation protocols.
引用
收藏
页码:2112 / 2122
页数:11
相关论文
共 40 条
[1]   Stereo-particle image velocimetry uncertainty quantification [J].
Bhattacharya, Sayantan ;
Charonko, John J. ;
Vlachos, Pavlos P. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (01)
[2]   Tomographic particle image velocimetry investigation of the flow in a modeled human carotid artery bifurcation [J].
Buchmann, N. A. ;
Atkinson, C. ;
Jeremy, M. C. ;
Soria, J. .
EXPERIMENTS IN FLUIDS, 2011, 50 (04) :1131-1151
[3]   In vitro flow investigations in the aortic arch during cardiopulmonary bypass with stereo-PIV [J].
Buesen, Martin ;
Kaufmann, Tim A. S. ;
Neidlin, Michael ;
Steinseifer, Ulrich ;
Sonntag, Simon J. .
JOURNAL OF BIOMECHANICS, 2015, 48 (10) :2005-2011
[4]   Quantification and visualization of cardiovascular 4D velocity mapping accelerated with parallel imaging or k-t BLAST: head to head comparison and validation at 1.5 T and 3 T [J].
Carlsson, Marcus ;
Toger, Johannes ;
Kanski, Mikael ;
Bloch, Karin Markenroth ;
Stahlberg, Freddy ;
Heiberg, Einar ;
Arheden, Hakan .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2011, 13
[5]   PIV measurements of flow in a centrifugal blood pump: Steady flow [J].
Day, SW ;
McDaniel, JC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (02) :244-253
[6]   Full-field velocity and temperature measurements using magnetic resonance imaging in turbulent complex internal flows [J].
Elkins, CJ ;
Markl, M ;
Iyengar, A ;
Wicker, R ;
Eaton, JK .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2004, 25 (05) :702-710
[7]   Tomographic particle image velocimetry [J].
Elsinga, G. E. ;
Scarano, F. ;
Wieneke, B. ;
van Oudheusden, B. W. .
EXPERIMENTS IN FLUIDS, 2006, 41 (06) :933-947
[8]   Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension [J].
Frydrychowicz, A. ;
Roldan-Alzate, A. ;
Winslow, E. ;
Consigny, D. ;
Campo, C. A. ;
Motosugi, U. ;
Johnson, K. M. ;
Wieben, O. ;
Reeder, S. B. .
EUROPEAN RADIOLOGY, 2017, 27 (12) :5316-5324
[9]   Experimental study of aortic flow in the ascending aorta via Particle Tracking Velocimetry [J].
Guelan, Utku ;
Luethi, Beat ;
Holzner, Markus ;
Liberzon, Alex ;
Tsinober, Arkady ;
Kinzelbach, Wolfgang .
EXPERIMENTS IN FLUIDS, 2012, 53 (05) :1469-1485
[10]   Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow [J].
Hope, Thomas A. ;
Hope, Michael D. ;
Purell, Derk D. ;
von Morze, Cornelius ;
Vigneron, Daniel B. ;
Alley, Marcus T. ;
Dillon, William P. .
MAGNETIC RESONANCE IMAGING, 2010, 28 (01) :41-46