Electrochemical Sensing of Acyclovir at a Gold Electrode Modified with 2-Mercaptobenzothiazole-[5,10,15,20-tetrakis-(3-methoxy-4-hydroxyphenyl)porphyrinato] copper(II)

被引:31
作者
Joseph, Renjini [1 ]
Kumar, K. Girish [1 ]
机构
[1] Cochin Univ Sci & Technol, Dept Appl Chem, Kochi 682022, India
关键词
SELF-ASSEMBLED MONOLAYERS; SUBSTITUTED PHTHALOCYANINES; METALLOPHTHALOCYANINES COMPLEXES; ELECTROCATALYTIC OXIDATION; CARBON ELECTRODE; BENZYL-MERCAPTO; HUMAN-PLASMA; FILMS; NITRITE; SAMS;
D O I
10.2116/analsci.27.67
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrooxidation of acyclovir (ACV) was studied using a gold electrode (GE) modified with a self-assembled monolayer of 2-mercaptobenzothiazol (MBZ) and [5,10,15,20-tetrakis(3-methoxy-4-hydroxyphenyl)porphyrinato]copper(II) (TMHPP Cu(II)) by square wave voltammetry (SWV). The self-assembled films are stable and showed blocking characteristics towards the faradaic processes such as gold surface oxidation and under potential deposition of copper. The optimized conditions obtained for the MBZ/TMHPP Cu(II)-modified GE were 0.1 M phosphate buffer solution (pH 7.0), square wave frequency of 15 Hz and square wave amplitude of 25 mV. Under these optimum conditions, the resultant peak current increases linearly with the concentration of ACV in the range of 1.0 x 10(-3) to 1.0 x 10(-8) M with a detection limit of 1.0 x 10(-8) M. The MBZ/TMHPP Cu(II)-modified GE showed good stability and selectivity and it can be used to quantify ACV in pharmaceutical formulations and urine samples.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 31 条