Spectrometric measurements of 131I and 99mTc activity in thyroid

被引:4
|
作者
Osko, J.
Golnik, N.
Pliszczynski, T.
机构
[1] Warsaw Univ Technol, Inst Precis & Biomed Engn, PL-02525 Warsaw, Poland
[2] Inst Atom Energy, PL-05400 Otwock, Poland
关键词
activity measurements; thyroid; iodine; technetium;
D O I
10.1016/j.nima.2007.05.238
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A modified method for calibration of the thyroid counter with I-131 was investigated in order to take into account the depth of the thyroid in human neck. The depth of the I-131 source was determined from the ratio of the counting rate in 364 keV peak to the counting rate in the energy band of 110-140 keV. Dependence of detector efficiency on the source depth was determined. The results were used for analysis of the energy spectra recorded for hospital patients. Similar method was investigated also for Tc-99m radiation source. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:578 / 581
页数:4
相关论文
共 50 条
  • [1] Comparison of thyroid volume and goiter measured by means of ultrasonography and SPECT with use of 131I and 99mTc in smokers and non-smokers
    Gierach, Marcin
    Gierach, Joanna
    Junik, Roman
    ENDOKRYNOLOGIA POLSKA, 2009, 60 (06) : 437 - 442
  • [2] Graphical analysis of 99mTc thyroid scintigraphy
    Okada, J
    Higashitsuji, Y
    Tamada, H
    Kawashiro, O
    Fukuzaki, T
    Suzuki, T
    Itou, H
    ANNALS OF NUCLEAR MEDICINE, 2003, 17 (03) : 235 - 238
  • [3] Measurements of 131I activity in thyroid of workers at the place of radioiodine therapy in 38 hospitals in China
    Li, Xiao-Liang
    Zhang, Jian-Feng
    Wang, Shuo
    Liu, Jian-Xiang
    Tuo, Fei
    Sun, Quan-Fu
    JOURNAL OF RADIATION RESEARCH, 2024, : 459 - 466
  • [4] Measurement of 131I activity in thyroid using a dual-layer detector
    Liu, Hongming
    Zhao, Chao
    Xu, Xiaohua
    Zhang, Weiyuan
    Yang, Shiyan
    Zhang, Zhiyong
    Chen, Bo
    Zhuo, Weihai
    RADIATION MEASUREMENTS, 2022, 153
  • [5] 99mTc thyroid imaging system using multiple imaging plates
    Ito, Shigeki
    Saze, Takuya
    Ariga, Eiji
    Deji, Shizuhiko
    Hirota, Masahiro
    Nishizawa, Kunihide
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (02): : 73 - 81
  • [6] 131I Intake and Regulatory Compliance Following Administration of Capsular 131I Sodium Iodide for Treatment of Thyroid Disorders
    Jafari, Mary Ellen
    Paik, David S.
    HEALTH PHYSICS, 2022, 122 (02): : 360 - 364
  • [7] Spectrometric measurements of radioisotope activity in the thyroid
    Osko, Jakub
    Golnik, Natalia
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2008, 14 (03): : 123 - 134
  • [8] Teff and thyroid remnants/blood activity ratio upon 131I therapy of patients with differentiated thyroid cancer
    Kozak, OV
    Chebotareva, ED
    Sinuta, BF
    Shishkina, VV
    EXPERIMENTAL ONCOLOGY, 2001, 23 (01): : 71 - 72
  • [9] Dosimetric methodology for 131I therapy for benign thyroid diseases
    Piron, B.
    Broggio, D.
    Bardies, M.
    Barrau, C.
    Kotzki, P. O.
    Boudousq, V
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2020, 44 (04): : 261 - 266
  • [10] Feasibility of in vivo thyroid 131I monitoring with an imaging plate
    Hirota, M
    Saze, T
    Ogata, Y
    Nishizawa, K
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 513 - 516