Cardiac output monitoring in pediatric patients

被引:7
作者
Nusmeier, Anneliese [1 ]
van der Hoeven, Johannes G. [1 ]
Lemson, Joris [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Intens Care Med, NL-6500 HB Nijmegen, Netherlands
关键词
cardiac output; hemodynamic monitoring; minimally invasive; noninvasive; pediatric critical care; transpulmonary thermodilution; PULSE DYE DENSITOMETRY; PULMONARY ARTERIAL THERMODILUTION; BLOOD-PRESSURE-MEASUREMENT; EXTRAVASCULAR LUNG WATER; END-DIASTOLIC VOLUME; TRANSPULMONARY THERMODILUTION; CONTOUR ANALYSIS; INDICATOR-DILUTION; ESOPHAGEAL DOPPLER; FICK PRINCIPLE;
D O I
10.1586/ERD.10.19
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiac output (CO) measurement is becoming increasingly important in the field of pediatric intensive care medicine and pediatric anesthesia. In the past few decades, various new technologies have been developed for the measurement of CO. Some of these methods are applicable to pediatric patients and some are already being used in children. The devices and methods have their advantages and limitations and, therefore, it is difficult for the clinician to decide which technique should be used. This article focuses on the currently available minimally invasive and noninvasive monitoring devices for CO measurement in children. A brief explanation of the technical aspects of each method and clinical use will be followed by the knowledge gained from infant animal and clinical pediatric studies. The goal of this article is to give an update of the various CO measurement technologies in children.
引用
收藏
页码:503 / 517
页数:15
相关论文
共 127 条
[1]  
*AAMI, 1993, ANSI SP, P40
[2]   Use of 3 French catheters for diagnostic and interventional procedures in newborns and small infants [J].
Agnoletti, G ;
Boudjemline, Y ;
Largen, E ;
Aggoun, Y ;
Szezepanski, I ;
Bonnet, D ;
Sidi, D .
HEART, 2003, 89 (11) :1350-1351
[3]   Measuring circulating blood volume in newborn infants using pulse dye densitometry and indocyanine green [J].
Aladangady, Narendra ;
Leung, Terence ;
Costeloe, Kate ;
Delpy, David .
PEDIATRIC ANESTHESIA, 2008, 18 (09) :865-871
[4]   Feasibility of Noninvasive continuous finger arterial blood pressure measurements in very young children, aged 0-4 years [J].
Andriessen, Peter ;
Schraa, Olaf ;
Van Den Bosch-Ruis, Wendy ;
Ten Harkel, Derk Jan ;
Settels, Jos J. ;
Oetomo, Sidarto Bambang ;
Blanco, Carlos E. .
PEDIATRIC RESEARCH, 2008, 63 (06) :691-696
[5]   Equipment review: New techniques for cardiac output measurement - oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis [J].
Berton, C ;
Cholley, B .
CRITICAL CARE, 2002, 6 (03) :216-221
[6]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[7]   Reconstruction of brachial artery pressure from noninvasive finger pressure measurements [J].
Bos, WJW ;
vanGoudoever, J ;
vanMontfrans, GA ;
vandenMeiracker, AH ;
Wesseling, KH .
CIRCULATION, 1996, 94 (08) :1870-1875
[8]   Evaluation of a noninvasive cardiac output monitor in mechanically ventilated children [J].
Botte, Astrid ;
Leclerc, Francis ;
Riou, Yvon ;
Sadik, Ahmed ;
Neve, Veronique ;
Rakza, Tameur ;
Richard, Adelaide .
PEDIATRIC CRITICAL CARE MEDICINE, 2006, 7 (03) :231-236
[9]   Use of echocardiography for hemodynamic monitoring [J].
Brown, JM .
CRITICAL CARE MEDICINE, 2002, 30 (06) :1361-1364
[10]   ESTIMATION OF CARDIAC INDEX BY MEANS OF THE ARTERIAL AND THE MIXED VENOUS OXYGEN-CONTENT AND PULMONARY OXYGEN-UPTAKE DETERMINATION IN THE EARLY POSTOPERATIVE PERIOD FOLLOWING SURGERY OF CONGENITAL HEART-DISEASE [J].
BUHEITEL, G ;
SCHARF, J ;
HOFBECK, M ;
SINGER, H .
INTENSIVE CARE MEDICINE, 1994, 20 (07) :500-503