Transoral thyroidectomy with a next generation flexible robotic system: A feasibility study in a cadaveric model

被引:12
作者
Chan, Jason Y. K. [1 ]
Koh, Yoon W. [2 ]
Richmon, Jeremy [3 ]
Kim, Jaewook [4 ]
Holsinger, F. Christopher [5 ]
Orloff, Lisa [5 ]
Anuwong, Angkoon [6 ]
机构
[1] Chinese Univ Hong Kong, Dept Otorhinolaryngol Head & Neck Surg, Hong Kong, Peoples R China
[2] Yonsei Univ, Coll Med, Dept Otorhinolaryngol, Seoul, South Korea
[3] Harvard Med Sch, Massachusetts Eye & Ear Infirm, Dept Otolaryngol Head & Neck Surg, Boston, MA 02115 USA
[4] Soonchunhyang Univ Hosp, Coll Med, Dept Otorhinolaryngol Head & Neck Surg, Seoul, South Korea
[5] Stanford Univ, Dept Otolaryngol, Div Head & Neck Surg, Palo Alto, CA 94304 USA
[6] Siam Univ, Fac Med, Police Gen Hosp, Dept Surg, 492-1 Rama I Rd, Bangkok 10330, Thailand
关键词
Transoral thyroidectomy; thyroidectomy; remote access; robotic surgery; Transoral Robotic Surgery (TORS); ENDOSCOPIC THYROIDECTOMY; SERIES;
D O I
10.21037/gs.2019.10.13
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Transoral endoscopic thyroidectomy provides access via the oral vestibule and gas insufflation to provide reliable remote access surgery to perform a total thyroidectomy. The da Vinci SP (Intuitive Surgical Inc., Sunnyvale, CA, USA) is a next generation flexible single port system that offers unique advantages over previous robotic rigid systems. Here we sought to evaluate the feasibility of performing transoral thyroidectomy with this next generation flexible robotic system. Methods: Cadaveric dissection with gas insufflation to test the feasibility of performing transoral thyroidectomy with the da Vinci SP. Results: A 2 cm incision was made in the oral vestibule and the working space created with a 1cm central port and two lateral 5 mm ports. Then an extra small wound protector (Applied Medical, Rancho Santa Margarita, CA) was placed through the central incision after closure of the 5 mm ports. The robotic system was then deployed through the wound protector while insufflation was maintained at similar to 6 mmHg. Three instrument arms were deployed. A fenestrated bipolar was used to grasp the thyroid gland while Maryland bipolars and monopolar scissors were used to mobilize each hemi lobe of the thyroid. The recurrent laryngeal nerves were seen and preserved bilaterally. After completion of the surgery and removal of the wound protector the vestibular incision was measured to be 3 cm. Further dissection to identify the mental nerves identified each nerve to be >1 cm from the lateral extent of the central incision. Conclusions: In summary, it is feasible to perform a total thyroidectomy with gas insufflation utilizing this next generation flexible robotic system. Further evaluation will be needed to validate the clinical applicability of this technique.
引用
收藏
页码:644 / +
页数:5
相关论文
共 9 条
  • [1] Transoral Endoscopic Thyroidectomy Vestibular Approach: A Series of the First 60 Human Cases
    Anuwong, Angkoon
    [J]. WORLD JOURNAL OF SURGERY, 2016, 40 (03) : 491 - 497
  • [2] Early results of a safety and feasibility clinical trial of a novel single-port flexible robot for transoral robotic surgery
    Chan, Jason Y. K.
    Wong, Eddy W. Y.
    Tsang, Raymond K.
    Holsinger, F. Christopher
    Tong, Michael C. F.
    Chiu, Philip W. Y.
    Ng, Simon S. M.
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2017, 274 (11) : 3993 - 3996
  • [3] Chan JY, 2019, ASVIDE, V6, P347
  • [4] Improved transoral dissection of the tongue base with a next-generation robotic surgical system
    Chen, Michelle M.
    Orosco, Ryan K.
    Lim, Gil Chai
    Holsinger, F. Christopher
    [J]. LARYNGOSCOPE, 2018, 128 (01) : 78 - 83
  • [5] Transoral endoscopic thyroidectomy via a vestibular approach: why and how?
    Dionigi, Gianlorenzo
    Chai, Young Jun
    Tufano, Ralph P.
    Anuwong, Angkoon
    Kim, Hoon Yub
    [J]. ENDOCRINE, 2018, 59 (02) : 275 - 279
  • [6] A flexible, single-arm robotic surgical system for transoral resection of the tonsil and lateral pharyngeal wall: Next-generation robotic head and neck surgery
    Holsinger, F. Christopher
    [J]. LARYNGOSCOPE, 2016, 126 (04) : 864 - 869
  • [7] A Novel Robotic System for Single-port Urologic Surgery: First Clinical Investigation
    Kaouk, Jihad H.
    Haber, Georges-Pascal
    Autorino, Riccardo
    Crouzet, Sebastien
    Ouzzane, Adil
    Flamand, Vincent
    Villers, Arnauld
    [J]. EUROPEAN UROLOGY, 2014, 66 (06) : 1033 - 1043
  • [8] Transoral robotic thyroidectomy (TORT): procedures and outcomes
    Richmon, Jeremy D.
    Kim, Hoon Yub
    [J]. GLAND SURGERY, 2017, 6 (03) : 285 - 289
  • [9] Transoral thyroidectomy and parathyroidectomy - A North American series of robotic and endoscopic transoral approaches to the central neck
    Russell, Jonathon O.
    Clark, James
    Noureldine, Salem I.
    Anuwong, Angkoon
    Al Khadem, Mai G.
    Kim, Hoon Yub
    Dhillon, Vaninder K.
    Dionigi, Gianlorenzo
    Tufano, Ralph P.
    Richmon, Jeremy D.
    [J]. ORAL ONCOLOGY, 2017, 71 : 75 - 80