Iterative-based Partial Volume Effects correction with wavelet-based regularization for quantitative PET imaging

被引:0
|
作者
Reilhac, Anthonin [1 ]
Lehnert, Wencke [2 ]
Lin, Jianyu [2 ]
Meikle, Steven R. [2 ]
Gregoire, Marie-Claude [1 ]
机构
[1] Australian Nucl Sci & Technol Org, Lucas Heights, NSW 2234, Australia
[2] Univ Sydney, Brain &Mind Res Inst, Sydney, NSW 2006, Australia
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
关键词
PET; Partial Volume Effect; denoising; iterative deconvolution; wavelet; DECONVOLUTION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two important technical limitations hampering quantitative measurements with dynamic PET imaging are 1) the limited spatial resolution of the detection system which induces quantitative biases due to Partial Volume Effects and 2), the poor counting statistics in the individual time frames which challenges further the subsequent kinetic modeling and analysis. In this work, we present an original method for the restoration of dynamic PET images that had suffered from both the consequences of the limited spatial resolution and the noise processes, which is based on the weighted least square iterative deconvolution in the wavelet space with temporal regularization of the wavelet coefficients. The solution image exhibits less noise, better contrasts between emitting structures and should therefore allow a better quantification compared with no correction..
引用
收藏
页码:3788 / 3791
页数:4
相关论文
共 50 条
  • [21] Effects of Background Activity On Partial Volume Correction (PVC) in PET Imaging
    Chang, T.
    Pan, T.
    Chang, G.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [22] Fully automated partial volume correction in PET based on a wavelet approach without the use of anatomical information
    Boussion, N.
    Hatt, M.
    Reilhac, A.
    Visvikis, D.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2812 - +
  • [23] The effects of iterative deconvolution partial-volume correction on beta-amyloid PET
    Thomas, B.
    Thurfjell, L.
    Rinne, J.
    Ourselin, S.
    Hutton, B.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2009, 29 : S337 - S338
  • [24] Partial volume correction in quantitative amyloid imaging
    Su, Yi
    Blazey, Tyler M.
    Snyder, Abraham Z.
    Raichle, Marcus E.
    Marcus, Daniel S.
    Ances, Beau M.
    Bateman, Randall J.
    Cairns, Nigel J.
    Aldea, Patricia
    Cash, Lisa
    Christensen, Jon J.
    Friedrichsen, Karl
    Hornbeck, Russ C.
    Farrar, Angela M.
    Owen, Christopher J.
    Mayeux, Richard
    Brickman, Adam M.
    Klunk, William
    Price, Julie C.
    Thompson, Paul M.
    Ghetti, Bernadino
    Saykin, Andrew J.
    Sperling, Reisa A.
    Johnson, Keith A.
    Schofield, Peter R.
    Buckles, Virginia
    Morris, John C.
    Benzinger, Tammie L. S.
    NEUROIMAGE, 2015, 107 : 55 - 64
  • [25] Towards optimal model-based partial volume effect correction in oncological PET imaging
    Schoenahl, F
    Zaidi, H
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3177 - 3181
  • [26] CT based partial volume correction in (11)C-PiB PET/CT imaging
    Imabavashi, Etsuko
    Matsuda, Hiroshi
    Kuji, Ichiei
    Seto, Akira
    Ito, Kimiteru
    Shimano, Yasumasa
    Yamada, Minoru
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [27] Simulation-based partial volume correction for dopaminergic PET imaging: Impact of segmentation accuracy
    Rong, Ye
    Vernaleken, Ingo
    Winz, Oliver H.
    Goedicke, Andreas
    Mottaghy, Felix M.
    Kops, Elena Rota
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (03): : 230 - 242
  • [28] Conditional partial volume correction for emission tomography: A wavelet-based hidden Markov model and multi-resolution approach
    Le Pogam, Adrien
    Hatt, Mathieu
    Boussion, Nicolas
    Guilloteau, Denis
    Baulieu, Jean-Louis
    Prunier, Caroline
    Turkheimer, Federico
    Visvikis, Dimitris
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1319 - +
  • [29] Wavelet-based partial discharge image denoising
    Florkowski, M.
    Florkowska, B.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2007, 1 (02) : 340 - 347
  • [30] Partial Volume Effect Correction in PET Using Regularized Iterative Deconvolution with Variance Control Based On Local Topology
    Kirov, A. S.
    Piao, J. Z.
    Schmidtlein, C. Ross
    MEDICAL PHYSICS, 2008, 35 (06)