Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T

被引:82
|
作者
Fernández-Seara, MA
Wang, Z
Wang, JJ
Rao, HY
Guenther, M
Feinberg, DA
Detre, JA
机构
[1] Univ Penn, Med Ctr, Dept Neurol, Ctr Funct Neuroimaging, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
[3] Adv MRI Technol, Sebastopol, CA USA
关键词
perfusion MRI; arterial spin labeling; human brain; cerebral blood flow; 3D GRASE imaging;
D O I
10.1002/mrm.20674
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single shot 3D GRASE is less sensitive to field inhomogeneity and susceptibility effects than gradient echo based fast imaging sequences while preserving the acquisition speed. In this study, a continuous arterial spin labeling (CASL) pulse was added prior to the single shot 3D GRASE readout and quantitative perfusion measurements were carried out at 3 T, at rest and during functional activation. The sequence performance was evaluated by comparison with a CASL sequence with EPI readout. It is shown that perfusion measurements using CASL GRASE can be performed safely on humans at 3 T without exceeding the current RF power deposition limits. The maps of resting cerebral blood flow generated from the GRASE images are comparable to those obtained with the 2D EPI readout, albeit with better coverage in the orbitofrontal cortex. The sequence proved effective for functional imaging, yielding time series of images with improved temporal SNR with respect to EPI and group activation maps with increased significance levels. The method was further improved using parallel imaging techniques to provide increased spatial resolution and better separation of the gray-white matter cerebral blood flow maps.
引用
收藏
页码:1241 / 1247
页数:7
相关论文
共 50 条
  • [21] Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling
    Shen, Qijia
    Wu, Wenchuan
    Chiew, Mark
    Ji, Yang
    Woods, Joseph G.
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1568 - 1583
  • [22] Whole Brain Perfusion Measurements Using Arterial Spin Labeling with Multiband Acquisition
    Kim, Tae
    Shin, Wanyong
    Zhao, Tiejun
    Beall, Erik B.
    Lowe, Mark J.
    Bae, Kyongtae T.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1653 - 1661
  • [23] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Chen, Zhiye
    Chen, Xiaoyan
    Liu, Mengyu
    Liu, Mengqi
    Ma, Lin
    Yu, Shengyuan
    JOURNAL OF HEADACHE AND PAIN, 2018, 19
  • [24] Simultaneous measurement of brain perfusion and labeling efficiency in a single pseudo-continuous arterial spin labeling scan
    Chen, Zhensen
    Zhao, Xihai
    Zhang, Xingxing
    Guo, Rui
    Teeuwisse, Wouter M.
    Zhang, Bida
    Koken, Peter
    Smink, Jouke
    Yuan, Chun
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1922 - 1930
  • [25] Regional reproducibility of pulsed arterial spin labeling perfusion imaging at 3T
    Wang, Yang
    Saykin, Andrew J.
    Pfeuffer, Josef
    Lin, Chen
    Mosier, Kristine M.
    Shen, Li
    Kim, Sungeun
    Hutchins, Gary D.
    NEUROIMAGE, 2011, 54 (02) : 1188 - 1195
  • [26] Evaluation of segmented 3D acquisition schemes for whole-brain high-resolution arterial spin labeling at 3 T
    Vidorreta, Marta
    Balteau, Evelyne
    Wang, Ze
    De Vita, Enrico
    Pastor, Maria A.
    Thomas, David L.
    Detre, John A.
    Fernandez-Seara, Maria A.
    NMR IN BIOMEDICINE, 2014, 27 (11) : 1387 - 1396
  • [27] Different post label delay cerebral blood flow measurements in patients with Alzheimer's disease using 3D arterial spin labeling
    Liu, Ying
    Zeng, Xiangzhu
    Wang, Zheng
    Zhang, Na
    Fan, Dongsheng
    Yuan, Huishu
    MAGNETIC RESONANCE IMAGING, 2015, 33 (09) : 1019 - 1025
  • [28] Transformer-based deep learning denoising of single and multi-delay 3D arterial spin labeling
    Shou, Qinyang
    Zhao, Chenyang
    Shao, Xingfeng
    Jann, Kay
    Kim, Hosung
    Helmer, Karl G.
    Lu, Hanzhang
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (02) : 803 - 818
  • [29] Decreased Cerebral Perfusion in Chronic Migraine: A Voxel-based Cerebral Blood Flow Analysis Using 3D Pseudo-continuous Arterial Spin Labeling
    Li X.
    Liu M.
    Zhao S.
    Chen Z.
    Current Medical Imaging, 2024, 20
  • [30] Use of 3D pseudo-continuous arterial spin labeling to characterize sex and age differences in cerebral blood flow
    Liu, Wenjia
    Lou, Xin
    Ma, Lin
    NEURORADIOLOGY, 2016, 58 (09) : 943 - 948