Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T

被引:82
|
作者
Fernández-Seara, MA
Wang, Z
Wang, JJ
Rao, HY
Guenther, M
Feinberg, DA
Detre, JA
机构
[1] Univ Penn, Med Ctr, Dept Neurol, Ctr Funct Neuroimaging, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
[3] Adv MRI Technol, Sebastopol, CA USA
关键词
perfusion MRI; arterial spin labeling; human brain; cerebral blood flow; 3D GRASE imaging;
D O I
10.1002/mrm.20674
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single shot 3D GRASE is less sensitive to field inhomogeneity and susceptibility effects than gradient echo based fast imaging sequences while preserving the acquisition speed. In this study, a continuous arterial spin labeling (CASL) pulse was added prior to the single shot 3D GRASE readout and quantitative perfusion measurements were carried out at 3 T, at rest and during functional activation. The sequence performance was evaluated by comparison with a CASL sequence with EPI readout. It is shown that perfusion measurements using CASL GRASE can be performed safely on humans at 3 T without exceeding the current RF power deposition limits. The maps of resting cerebral blood flow generated from the GRASE images are comparable to those obtained with the 2D EPI readout, albeit with better coverage in the orbitofrontal cortex. The sequence proved effective for functional imaging, yielding time series of images with improved temporal SNR with respect to EPI and group activation maps with increased significance levels. The method was further improved using parallel imaging techniques to provide increased spatial resolution and better separation of the gray-white matter cerebral blood flow maps.
引用
收藏
页码:1241 / 1247
页数:7
相关论文
共 50 条
  • [1] Diffusion sensitivity of 3D-GRASE in arterial spin labeling perfusion
    He, Xiang
    Wengler, Kenneth
    Schweitzer, Mark E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 736 - 747
  • [2] Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements
    Günther, M
    Oshio, K
    Feinberg, DA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 491 - 498
  • [3] 3D GRASE PROPELLER: Improved Image Acquisition Technique for Arterial Spin Labeling Perfusion Imaging
    Tan, Huan
    Hoge, W. Scott
    Hamilton, Craig A.
    Guenther, Matthias
    Kraft, Robert A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 168 - 173
  • [4] Comparison of 2D simultaneous multi-slice and 3D GRASE readout schemes for pseudo-continuous arterial spin labeling of cerebral perfusion at 3 T
    Manjunathan Nanjappa
    Thomas Troalen
    Josef Pfeuffer
    Bénédicte Maréchal
    Tom Hilbert
    Tobias Kober
    Fabien C. Schneider
    Pierre Croisille
    Magalie Viallon
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 437 - 450
  • [5] Comparison of 2D simultaneous multi-slice and 3D GRASE readout schemes for pseudo-continuous arterial spin labeling of cerebral perfusion at 3 T
    Nanjappa, Manjunathan
    Troalen, Thomas
    Pfeuffer, Josef
    Marechal, Benedicte
    Hilbert, Tom
    Kober, Tobias
    Schneider, Fabien C.
    Croisille, Pierre
    Viallon, Magalie
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (03) : 437 - 450
  • [6] Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T
    Mildner, T
    Trampel, R
    Möller, HE
    Schäfer, A
    Wiggins, CJ
    Norris, DG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (05) : 791 - 795
  • [7] 3D GRASE pulsed arterial spin labeling at multiple inflow times in patients with long arterial transit times: comparison with dynamic susceptibility-weighted contrast-enhanced MRI at 3 Tesla
    Martin, Steve Z.
    Madai, Vince I.
    von Samson-Himmelstjerna, Federico C.
    Mutke, Matthias A.
    Bauer, Miriam
    Herzig, Cornelius X.
    Hetzer, Stefan
    Guenther, Matthias
    Sobesky, Jan
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2015, 35 (03) : 392 - 401
  • [8] Cerebral perfusion measurements using continuous arterial spin labeling: accuracy and limits of a quantitative approach
    Kimura, H
    Kabasawa, H
    Yonekura, Y
    Itoh, H
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 238 - 247
  • [9] Intra- and Interscanner Reliability and Reproducibility of 3D Whole-Brain Pseudo-Continuous Arterial Spin-Labeling MR Perfusion at 3T
    Wu, Bing
    Lou, Xin
    Wu, Xinhuai
    Ma, Lin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 402 - 409
  • [10] Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
    Talagala, SL
    Ye, FQ
    Ledden, PJ
    Chesnick, S
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 131 - 140