Energy Efficiency of Novel Interior Surface Layer with Improved Thermal Characteristics and Its Effect on Hygrothermal Performance of Contemporary Building Envelopes

被引:7
作者
Fort, Jan [1 ,2 ]
Sal, Jiri [1 ]
Koci, Jan [2 ]
Cerny, Robert [2 ]
机构
[1] Inst Technol & Business Ceske Budejovice, Fac Technol, Ceske Budejovice 37001, Czech Republic
[2] Czech Tech Univ, Fac Civil Engn, Prague 16629, Czech Republic
关键词
plaster; thermal energy storage; computation simulation; recuperation heat; passive cooling; climate; PHASE-CHANGE MATERIALS; AIR-CONDITIONING SYSTEM; THERMOPHYSICAL PROPERTIES; HUMIDITY CONTROL; PCM; STORAGE; CLIMATE; SHAPE; INSULATION; BEHAVIOR;
D O I
10.3390/en13082012
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Facing the consequences of climate change and fuel price rises, the achievement of the requirements for low-energy consumption of buildings has become a challenging issue. On top of that, increased demands on indoor hygrothermal conditions usually require the utilization of additional heating, ventilation, and air-conditioning (HVAC) systems to maintain a comfortable environment. On this account, several advanced and modern materials are widely investigated as a promising way for reduction of the buildings' energy consumption including utilization of passive heating/cooling energy. However, the efficiency and suitability of passive strategies depending on several aspects including the influence of location, exterior climatic conditions, load-bearing materials used, and insulation materials applied. The main objective of this study consists of the investigation of the energy performance benefits gained by the utilization of advanced materials in plasters by computational modeling. Results obtained from a computational simulation reveal the capability of the studied passive cooling/heating methods on the moderation of indoor air quality together with the reduction of the diurnal temperature fluctuation. Achieved results disclose differences in terms of energy savings for even small variation in outdoor climate conditions. Additionally, the effectivity of passive cooling/heating alters considerably during the summer and winter periods. Based on the analysis of simulated heat fluxes, the potential energy savings related to improved thermal properties of the applied plaster layer reached up to 12.08% and thus represent an interesting passive solution towards energy sustainability to meet the criteria on modern buildings.
引用
收藏
页数:17
相关论文
共 65 条
  • [1] An innovative PCM system for thermal comfort improvement and energy demand reduction in building under different climate conditions
    Ahangari, Mohamad
    Maerefat, Mehdi
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2019, 44 : 120 - 129
  • [2] Passive cooling techniques for building and their applicability in different climatic zones-The state of art
    Bhamare, Dnyandip K.
    Rathod, Manish K.
    Banerjee, Jyotirmay
    [J]. ENERGY AND BUILDINGS, 2019, 198 : 467 - 490
  • [3] Combined experimental and numerical evaluation of a prototype nano-PCM enhanced wallboard
    Biswas, Kaushik
    Lu, Jue
    Soroushian, Parviz
    Shrestha, Som
    [J]. APPLIED ENERGY, 2014, 131 : 517 - 529
  • [4] Review of moisture behavior and thermal performance of polystyrene insulation in building applications
    Cai, Shanshan
    Zhang, Boxiong
    Cremaschi, Lorenzo
    [J]. BUILDING AND ENVIRONMENT, 2017, 123 : 50 - 65
  • [5] A direct expansion based enhanced dehumidification air conditioning system for improved year-round indoor humidity control in hot and humid climates
    Chen, Wenjing
    Chan, Ming-yin
    Deng, Shiming
    Yan, Huaxia
    Weng, Wenbing
    [J]. BUILDING AND ENVIRONMENT, 2018, 139 : 95 - 109
  • [6] Experimental research on the use of micro-encapsulated Phase Change Materials to store solar energy in concrete floors and to save energy in Dutch houses
    Entrop, A. G.
    Brouwers, H. J. H.
    Reinders, A. H. M. E.
    [J]. SOLAR ENERGY, 2011, 85 (05) : 1007 - 1020
  • [7] Adjustment of thermal behavior by changing the shape of PCM inclusions in concrete blocks
    Erlbeck, L.
    Schreiner, P.
    Schlachter, K.
    Doernhofer, P.
    Fasel, F.
    Methner, F. -J.
    Raedle, M.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 158 : 256 - 265
  • [8] Energy-efficiency building retrofit planning for green building compliance
    Fan, Yuling
    Xia, Xiaohua
    [J]. BUILDING AND ENVIRONMENT, 2018, 136 : 312 - 321
  • [9] Impacts of airflows, internal heat and moisture gains on accuracy of modeling energy consumption and indoor parameters in passive building
    Firlag, Szymon
    Zawada, Bernard
    [J]. ENERGY AND BUILDINGS, 2013, 64 : 372 - 383
  • [10] Preparation and Characterization of Novel Plaster with Improved Thermal Energy Storage Performance
    Fort, Jan
    Novotny, Radimir
    Trnik, Anton
    Cerny, Robert
    [J]. ENERGIES, 2019, 12 (17)