Micellar electrokinetic chromatography-mass spectrometry using a polymerized chiral surfactant

被引:74
作者
Shamsi, SA [1 ]
机构
[1] Georgia State Univ, Dept Chem, Ctr Biotechnol & Drug Design, Atlanta, GA 30303 USA
关键词
D O I
10.1021/ac0105179
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The coupling of chiral micellar electrokinetic chromatography (CMEKC) to mass spectrometry (MS) using conventional surfactant [above the critical micelle concentration (cmc)] is very challenging. Preliminary investigation in this laboratory indicates that the use of a chiral polymeric surfactant provides one possible solution to this difficult coupling. This is because of many positive attributes of micelle polymers which include zero cmc, lower surface activity, low volatility, high electrophoretic mobility, and function as a suitable separation medium even at lower concentrations of pseudophases. In this work, the feasibility of using poly(sodium N-undecanoyl-L-valinate (poly-L-SUV) in CMEKC-MS is demonstrated. After CMEKC separation, enantiomers of 1, 1'-binaphthol (BOH) were detected using electrospray ionization mass spectrometry (ESI-MS) by selected ion monitoring (SIM) in the negative ion mode. Although in the SIM mode ESI-MS parameters (nebulizer pressure, drying gas flow rate, drying gas temperature, and sheath liquid flow rate) affected only the signal-to-noise ratio of (+/- )BOH, two of the ESI-MS parameters (nebulizer pressure, sheath flow rate) were found to have a significant impact on chiral resolution of (+/- )BOH. At the optimum ESI-MS conditions, the enantioseparation of (+/- )BOH was successfully accomplished by varying the buffer pH, concentration of the volatile background electrolyte, and poly-L-SUV.
引用
收藏
页码:5103 / 5108
页数:6
相关论文
共 44 条
[31]   Mechanism of signal suppression by an ionic surfactants in capillary electrophoresis electrospray ionization mass spectrometry [J].
Rundlett, KL ;
Armstrong, DW .
ANALYTICAL CHEMISTRY, 1996, 68 (19) :3493-3497
[32]   Monomeric and polymeric chiral surfactants as pseudo-stationary phases for chiral separations [J].
Shamsi, SA ;
Warner, IM .
ELECTROPHORESIS, 1997, 18 (06) :853-872
[33]   Polymeric anionic surfactant for electrokinetic chromatography: Separation of 16 priority polycyclic aromatic hydrocarbon pollutants [J].
Shamsi, SA ;
Akbay, C ;
Warner, IM .
ANALYTICAL CHEMISTRY, 1998, 70 (14) :3078-3083
[34]   Improved chiral separations using a polymerized dipeptide anionic chiral surfactant in electrokinetic chromatography: Separations of basic, acidic, and neutral racemates [J].
Shamsi, SA ;
Macossay, J ;
Warner, IM .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :2980-2987
[35]   Amino acid analysis by capillary electrophoresis electrospray ionization mass spectrometry [J].
Soga, T ;
Heiger, DN .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1236-1241
[36]   Application of sulfated cyclodextrins to chiral separations by capillary zone electrophoresis [J].
Stalcup, AM ;
Gahm, KH .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1360-1368
[37]  
StClaire RL, 1996, ANAL CHEM, V68, pR569
[38]  
STINSON CS, 2000, CHEM ENG NEWS, P55
[39]   Reversed-phase liquid chromatographic separation of enantiomers on polysaccharide type chiral stationary phases [J].
Tachibana, K ;
Ohnishi, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 906 (1-2) :127-154
[40]  
Tang YB, 1996, CHIRALITY, V8, P136