Occurrence of secondary fracture around intramedullary nails used for trochanteric hip fractures: A systematic review of 13,568 patients

被引:101
作者
Norris, Rory [1 ]
Bhattacharjee, Dhritiman [1 ]
Parker, Martyn J. [1 ]
机构
[1] Peterborough Dist Gen Hosp, Peterborough PE3 6DA, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2012年 / 43卷 / 06期
关键词
Intramedullary nail; Trochanteric hip fracture; Peri-prosthetic fracture; Secondary fracture; SCREW;
D O I
10.1016/j.injury.2011.10.027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: A sliding hip screw (SHS) is currently the treatment of choice for trochanteric hip fractures, largely due to the low incidence of complications. An alternative treatment is the use of intramedullary proximal femoral nails. Unfortunately these implants have been associated with a risk of later fracture around the implant. The aim of this study was to see if any improvements have been made to the current intramedullary nails, to reduce the incidence of secondary fracture around the distal tip of the nail. Methods: We analysed data related to 13,568 patients from 89 studies, focusing on the incidence of post operative secondary femoral shaft fracture following the use of intramedullary nails in the fixation of trochanteric hip fractures. Results: The overall reported incidence of secondary fracture around the nail was 1.7%. The incidence of fracture has reduced in the 3rd generation Gamma nails when compared to the older Gamma nail (1.7% versus 2.6%, p value 0.03). However, the incidence of secondary fracture in the 3rd generation Gamma nails is still significantly higher than the other brands of short nail (1.7% versus 0.7%, p value 0.0005). Long nails had a slight tendency towards a lower risk of fracture although the difference was not statistically significant (1.1% versus 1.7%, p value 0.28). There was a significantly lower risk of fracture for those nails with a biaxial fixation as opposed to uniaxial fixation (0.6% versus 1.9%, p value <0.0001). Conclusion: Secondary fracture around a proximal femoral nail is one of the most significant of fracture healing complications, and this study suggests that continuing design changes to this method of fixation has reduced the risk of this complication occurring. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:706 / 711
页数:6
相关论文
共 96 条
[1]   Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]  
Ahrengart L, 2002, CLIN ORTHOP RELAT R, P209
[3]   The AO/ASIF proximal femoral nail (PFN) for the treatment of unstable trochanteric femoral fracture [J].
Al-yassari, G ;
Langstaff, RJ ;
Jones, JWM ;
Al-Lami, M .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (05) :395-399
[4]  
Anglen JO, 2008, J BONE JOINT SURG AM, V9, P700
[5]  
[Anonymous], 2001, J BONE JOINT SURG BR
[6]  
[Anonymous], 2000, INJURY
[7]   GAMMA-NAIL VS COMPRESSION SCREW FOR TROCHANTERIC FEMORAL FRACTURES - 15 REOPERATIONS IN A PROSPECTIVE, RANDOMIZED STUDY OF 378 PATIENTS [J].
AUNE, AK ;
EKELAND, A ;
ODEGAARD, B ;
GROGAARD, B ;
ALHO, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :127-130
[8]   The treatment of unstable, extracapsular hip fractures with the AO/ASIF proximal femoral nail (PFN) - our first 60 cases [J].
Banan, H ;
Al-Sabti, A ;
Jimulia, T ;
Hart, AJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (05) :401-405
[9]   A Comparison of the Long Gamma Nail with the Sliding Hip Screw for the Treatment of AO/OTA 31-A2 Fractures of the Proximal Part of the Femur A Prospective Randomized Trial [J].
Barton, Tristan M. ;
Gleeson, Robert ;
Topliss, Claire ;
Greenwood, Rosemary ;
Harries, William J. ;
Chesser, Timothy J. S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (04) :792-798
[10]  
Baumgaertner MR, 1998, CLIN ORTHOP RELAT R, P87