Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques

被引:493
作者
Gelalis, Ioannis D. [1 ]
Paschos, Nikolaos K. [1 ]
Pakos, Emilios E. [1 ]
Politis, Angelos N. [1 ]
Arnaoutoglou, Christina M. [1 ]
Karageorgos, Athanasios C. [1 ]
Ploumis, Avraam [1 ]
Xenakis, Theodoros A. [1 ]
机构
[1] Univ Ioannina, Sch Med, Dept Orthopaed Surg & Traumatol, Ioannina 45221, Epirus, Greece
关键词
Pedicle screw; Free hand; Fluoroscopy; Fluoro-based; Computed tomography; Navigation; COMPUTED-TOMOGRAPHY; IDIOPATHIC SCOLIOSIS; THORACOLUMBAR SPINE; THORACIC SPINE; LUMBAR SPINE; FIXATION; INSERTION; COMPLICATIONS; INSTRUMENTATION; ASSISTANCE;
D O I
10.1007/s00586-011-2011-3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
With the advances and improvement of computer-assisted surgery devices, computer-guided pedicle screws insertion has been applied to the lumbar, thoracic and cervical spine. The purpose of the present study was to perform a systematic review of all available prospective evidence regarding pedicle screw insertion techniques in the thoracic and lumbar human spine. We considered all prospective in vivo clinical studies in the English literature that assessed the results of different pedicle screw placement techniques (free-hand technique, fluoroscopy guided, computed tomography (CT)-based navigation, fluoro-based navigation). MEDLINE, OVID, and Springer databases were used for the literature search covering the period from January 1950 until May 2010. 26 prospective clinical studies were eventually included in the analysis. These studies included in total 1,105 patients in which 6,617 screws were inserted. In the studies using free-hand technique, the percentage of the screws fully contained in the pedicle ranged from 69 to 94%, with the aid of fluoroscopy from 28 to 85%, using CT navigation from 89 to 100% and using fluoroscopy-based navigation from 81 to 92%. The screws positioned with free-hand technique tended to perforate the cortex medially, whereas the screws placed with CT navigation guidance seemed to perforate more often laterally. In conclusion, navigation does indeed exhibit higher accuracy and increased safety in pedicle screw placement than free-hand technique and use of fluoroscopy.
引用
收藏
页码:247 / 255
页数:9
相关论文
共 45 条
[1]   Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine [J].
Amiot, LP ;
Lang, K ;
Putzier, M ;
Zippel, H ;
Labelle, H .
SPINE, 2000, 25 (05) :606-614
[2]   Lumbar pedicle screws versus hooks - Results in double major curves in adolescent idiopathic scoliosis [J].
Barr, SJ ;
Schuette, AM ;
Emans, JB .
SPINE, 1997, 22 (12) :1369-1379
[3]   Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fractures [J].
Beck, Markus ;
Mittlmeier, Thomas ;
Gierer, Philip ;
Harms, Christoph ;
Gradl, Georg .
EUROPEAN SPINE JOURNAL, 2009, 18 (10) :1469-1477
[4]   SPINAL-FUSION AUGMENTED BY LUQUE-ROD SEGMENTAL INSTRUMENTATION FOR NEUROMUSCULAR SCOLIOSIS [J].
BROOM, MJ ;
BANTA, JV ;
RENSHAW, TS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01) :32-44
[5]   In vivo pedicle screw placement: Image-guided virtual vision [J].
Carl, AL ;
Khanuja, HS ;
Gatto, CA ;
Matsumoto, M ;
vomLehn, J ;
Schenck, J ;
Rohling, K ;
Lorensen, W ;
Vosburgh, K .
JOURNAL OF SPINAL DISORDERS, 2000, 13 (03) :225-229
[6]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[7]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[8]   Accuracy and safety of pedicle screw fixation in thoracic spine trauma [J].
Fisher, Charles G. ;
Sahajpal, Vic ;
Keynan, Ory ;
Boyd, Michael ;
Graeb, Douglas ;
Bailey, Christopher ;
Panagiotopoulos, Kostas ;
Dvorak, Marcel F. .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 5 (06) :520-526
[9]   Computer-assisted fluoroscopic navigation of pedicle screw insertion - An in vivo feasibility study [J].
Fu, TS ;
Chen, LH ;
Wong, CB ;
Lai, PL ;
Tsai, TT ;
Niu, CC ;
Chen, WJ .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (06) :730-735
[10]   The use of pedicle-screw internal fixation for the operative treatment of spinal disorders [J].
Gaines, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (10) :1458-1476