Primary Stability of Dental Implants in Low-Density (10 and 20 pcf) Polyurethane Foam Blocks: Conical vs Cylindrical Implants

被引:42
作者
Comuzzi, Luca
Tumedei, Margherita [1 ]
Pontes, Ana Emilia [2 ]
Piattelli, Adriano [1 ,3 ,4 ]
Iezzi, Giovanna [1 ]
机构
[1] Univ G dAnnunzio, Dept Med Oral & Biotechnol Sci, I-66100 Chieti, Italy
[2] Univ Fed Juiz de Fora, Dept Dent, Campus Governador Valadares, BR-01000 Sao Paulo, Brazil
[3] Catholic Univ San Antonio Murcia UCAM, Biomat Engn, Murcia 30001, Spain
[4] Fdn Villaserena Ric, I-65121 Pescara, Italy
关键词
bone density; cylindrical implants; conical implants; implant stability quotient; insertion and pull-out torque; polyurethane foam blocks; primary stability; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; SITE PREPARATION; EXTRACTION SOCKETS; IN-VITRO; BONE; SURGERY; OSTEOTOMY; QUALITY; VALUES;
D O I
10.3390/ijerph17082617
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Background: The aim of the present study was to compare, in low-density polyurethane blocks, the primary implant stability values (micromobility) and removal torque values of three different implant geometries in two different bone densities representing the structure of the human posterior jaws. Methods: A total of 60 implants were used in the present investigation: twenty implants for each of three groups (group A, group B, and group C), in both polyurethane 10 pcf and 20 pcf densities. The insertion torque, pull-out torque, and implant stability quotient (ISQ) values were obtained. Results: No differences were found in the values of Group A and Group B implants. In both these groups, the insertion torques were quite low in the 10 pcf blocks. Better results were found in the 20 pcf blocks, which showed very good stability of the implants. The pull-out values were slightly lower than the insertion torque values. High ISQ values were found in Group A and B implants. Lower values were present in Group C implants. Conclusions: The present investigation evaluated implants with different geometries that are available on the market, and not experimental implants specifically created for the study. The authors aimed to simulate real clinical conditions (poor-density bone or immediate post-extraction implants) in which knowledge of dental implant features, which may be useful in increasing the primary stability, may help the oral surgeon during the surgery planning.
引用
收藏
页数:11
相关论文
共 45 条
[1]  
Aleo E, 2012, J BIOL REG HOMEOS AG, V26, P89
[2]   Histological and Histomorphometric Analyses of Two Bovine Bone Blocks Implanted in Rabbit Calvaria [J].
Alexandre Gehrke, Sergio ;
Mazon, Patricia ;
Del Fabbro, Massimo ;
Tumedei, Margherita ;
Arambuth Junior, Jaime ;
Perez-Diaz, Leticia ;
De Aza, Piedad N. .
SYMMETRY-BASEL, 2019, 11 (05)
[3]   Impact of Different Titanium Implant Thread Designs on Bone Healing: A Biomechanical and Histometric Study with an Animal Model [J].
Alexandre Gehrke, Sergio ;
Eliers Treichel, Tiago Luis ;
Perez-Diaz, Leticia ;
Calvo-Guirado, Jose Luis ;
Aramburu, Jaime, Jr. ;
Mazon, Patricia ;
de Aza, Piedad N. .
JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
[4]  
Allen R., 1998, Annual Book of ASTM Standards, Medical Devices and Services
[5]   Alveolar socket healing: what can we learn? [J].
Araujo, Mauricio G. ;
Silva, Cleverson O. ;
Misawa, Monica ;
Sukekava, Flavia .
PERIODONTOLOGY 2000, 2015, 68 (01) :122-134
[6]   Short vs. Standard Length Cone Morse Connection Implants: An In Vitro Pilot Study in Low Density Polyurethane Foam [J].
Comuzzi, Luca ;
Tumedei, Margherita ;
Piattelli, Adriano ;
Iezzi, Giovanna .
SYMMETRY-BASEL, 2019, 11 (11)
[7]   An In Vitro Evaluation, on Polyurethane Foam Sheets, of the Insertion Torque (IT) Values, Pull-Out Torque Values, and Resonance Frequency Analysis (RFA) of NanoShort Dental Implants [J].
Comuzzi, Luca ;
Iezzi, Giovanna ;
Piattelli, Adriano ;
Tumedei, Margherita .
POLYMERS, 2019, 11 (06)
[8]  
Dahiya Kirti, 2018, J Contemp Dent Pract, V19, P426
[9]   Evaluation of factors influencing resonance frequency analysis values, at insertion surgery, of implants placed in sinus-augmented and nongrafted sites [J].
Degidi, Marco ;
Daprile, Giuseppe ;
Piattelli, Adriano ;
Carinci, Francesco .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2007, 9 (03) :144-149
[10]   Influence of Stepped Osteotomy on Primary Stability of Implants Inserted in Low-Density Bone Sites: An In Vitro Study [J].
Degidi, Marco ;
Daprile, Giuseppe ;
Piattelli, Adriano .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) :37-41