Reduction of Metal Artifact in Single Photon-Counting Computed Tomography by Spectral-Driven Iterative Reconstruction Technique

被引:30
|
作者
Nasirudin, Radin A. [1 ]
Mei, Kai [1 ]
Panchev, Petar [2 ]
Fehringer, Andreas [3 ,4 ]
Pfeiffer, Franz [3 ,4 ]
Rummeny, Ernst J. [1 ]
Fiebich, Martin [2 ]
Noel, Peter B. [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Hsch Mittelhessen, Inst Med Phys & Strahlenschutz, D-35390 Giessen, Germany
[3] Tech Univ Munich, Chair Biomed Phys, D-85748 Garching, Germany
[4] Tech Univ Munich, Inst Med Engn, D-85748 Garching, Germany
来源
PLOS ONE | 2015年 / 10卷 / 05期
关键词
CT;
D O I
10.1371/journal.pone.0124831
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The exciting prospect of Spectral CT (SCT) using photon-counting detectors (PCD) will lead to new techniques in computed tomography (CT) that take advantage of the additional spectral information provided. We introduce a method to reduce metal artifact in X-ray tomography by incorporating knowledge obtained from SCT into a statistical iterative reconstruction scheme. We call our method Spectral-driven Iterative Reconstruction (SPIR). Method The proposed algorithm consists of two main components: material decomposition and penalized maximum likelihood iterative reconstruction. In this study, the spectral data acquisitions with an energy-resolving PCD were simulated using a Monte-Carlo simulator based on EGSnrc C++ class library. A jaw phantom with a dental implant made of gold was used as an object in this study. A total of three dental implant shapes were simulated separately to test the influence of prior knowledge on the overall performance of the algorithm. The generated projection data was first decomposed into three basis functions: photoelectric absorption, Compton scattering and attenuation of gold. A pseudo-monochromatic sinogram was calculated and used as input in the reconstruction, while the spatial information of the gold implant was used as a prior. The results from the algorithm were assessed and bench-marked with state-of-the-art reconstruction methods. Results Decomposition results illustrate that gold implant of any shape can be distinguished from other components of the phantom. Additionally, the result from the penalized maximum likelihood iterative reconstruction shows that artifacts are significantly reduced in SPIR reconstructed slices in comparison to other known techniques, while at the same time details around the implant are preserved. Quantitatively, the SPIR algorithm best reflects the true attenuation value in comparison to other algorithms. Conclusion It is demonstrated that the combination of the additional information from Spectral CT and statistical reconstruction can significantly improve image quality, especially streaking artifacts caused by the presence of materials with high atomic numbers.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A New Iterative Metal Artifact Reduction Algorithm for Both Energy-Integrating and Photon-Counting CT Systems
    Anhaus, Julian A.
    Heider, Maximilian
    Killermann, Philipp
    Hofmann, Christian
    Mahnken, Andreas H.
    INVESTIGATIVE RADIOLOGY, 2024, 59 (07) : 526 - 537
  • [22] SIMULTANEOUS SPECTRAL AND TEMPORAL RESOLUTION IN A SINGLE PHOTON-COUNTING TECHNIQUE
    AINBUND, MR
    BUEVICH, OE
    KAMALOV, VF
    MENSHIKOV, GA
    TOLEUTAEV, BN
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (06): : 3274 - 3279
  • [23] Polychromatic Iterative Statistical Material Image Reconstruction for Photon-Counting Computed Tomography (vol 2016, 5871604, 2016)
    Weidinger, Thomas
    Buzug, Thorsten M.
    Flohr, Thomas G.
    Kappler, Steffen
    Stierstorfer, Karl
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2018, 2018
  • [24] Metal artifact correction in photon-counting detector computed tomography: metal trace replacement using high-energy data
    Richtsmeier, Devon
    O'Connell, Jericho
    Rodesch, Pierre-Antoine
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    MEDICAL PHYSICS, 2023, 50 (01) : 380 - 396
  • [25] Spectral Photon-Counting Computed Tomography: A Review on Technical Principles and Clinical Applications
    Tortora, Mario
    Gemini, Laura
    D'Iglio, Imma
    Ugga, Lorenzo
    Spadarella, Gaia
    Cuocolo, Renato
    JOURNAL OF IMAGING, 2022, 8 (04)
  • [26] Extension of Axial Coverage and Artifact Reduction in Iterative Reconstruction in Computed Tomography
    Zamyatin, Alexander A.
    Shi, Daxin
    Dinu, Mihail Petru
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4145 - 4147
  • [27] Review of an initial experience with an experimental spectral photon-counting computed tomography system
    Si-Mohamed, Salim
    Bar-Ness, Daniel
    Sigovan, Monica
    Cormode, David P.
    Coulon, Philippe
    Coche, Emmanuel
    Vlassenbroek, Alain
    Normand, Gabrielle
    Boussel, Loic
    Douek, Philippe
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 873 : 27 - 35
  • [28] Spectral computed tomography in the age of photon-counting X-ray detectors
    Rotkopf, Lukas T.
    Wehrse, Eckhard
    Froelich, Matthias F.
    RADIOLOGIE, 2022, 62 (06): : 504 - 510
  • [29] Spectral response model for a multibin photon-counting spectral computed tomography detector and its applications
    Liu, Xuejin
    Persson, Mats
    Bornefalk, Hans
    Karlsson, Staffan
    Xu, Cheng
    Danielsson, Mats
    Huber, Ben
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (03)
  • [30] Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography
    Yu, Zhicong
    Leng, Shuai
    Li, Zhoubo
    McCollough, Cynthia H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (18): : 6707 - 6732