A clinical protocol for analysis of the structural integrity of the Medtronic CoreValve System® frame and its application in patients with 1-year minimum follow-up

被引:13
作者
Piazza, Nicolo [1 ]
Grube, Eberhard [2 ]
Gerckens, Ulrich [2 ]
Schuler, Gerhard [3 ]
Linke, Axel [3 ]
den Heijer, Peter [4 ]
Kovacs, Jan [5 ]
Spyt, Tom [5 ]
Laborde, Jean-Claude [5 ]
Morel, Marie-Angele [6 ]
Nuis, Rutger-Jan [1 ]
Garcia-Garcia, Hector M. [6 ]
de Jaegere, Peter [1 ]
Serruys, Patrick W. [1 ]
机构
[1] Thorax Ctr Rotterdam, Dept Intervent Cardiol, NL-3015 CE Rotterdam, Netherlands
[2] Helios Herzzentrum, Dept Intervent Cardiol, Siegburg, Germany
[3] Herzzentrum Leipzig, Dept Intervent Cardiol, Leipzig, Germany
[4] Amphia Hosp, Dept Intervent Cardiol, Breda, Netherlands
[5] Glenfield Hosp, Dept Intervent Cardiol, Leicester, Leics, England
[6] Cardialysis, Rotterdam, Netherlands
关键词
Aortic valve disease; valvular heart disease; aortic stenosis; transcatheter aortic valve implantation; valve fracture; PULMONARY VALVE IMPLANTATION; SUPERFICIAL FEMORAL-ARTERY; NITINOL STENTS; FRACTURE; IMPACT; TRIAL;
D O I
10.4244/EIJV5I6A112
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The optimal clinical protocol to detect fractures of transcatheter aortic valves is unknown. To the best of our knowledge, there are no published reports describing stent or frame fractures following transcatheter aortic valve implantation. The purpose of this study is two-fold: (1) to determine the optimal fluoroscopic protocol to identify potential fractures of the Medtronic CoreValve (R) frame; and (2) to implement this protocol in the analysis of the fluoroscopic films of patients implanted with the CoreValve (R) device with 1-year minimum follow-up. Methods and results: Considering the resolution of fluoroscopy (similar to 0.2 mm), we used a 0.2 mm diamond-cutter to create a single fracture in a single strut of two CoreValve (R) frames. An intact CoreValve (R) prosthesis was used as control. These prostheses were subsequently implanted in post-mortem heart specimens. A protocol involving still frames and rotational (left-right and cranial-caudal) fluoroscopic imaging was then applied to the heart specimens. The experimentally induced fractures were detectable on the rotational cine runs (left-right and cranial-caudal); in some of the fixed acquisition sequences, however, the fractures were undetectable. The fluoroscopic protocol was retrospectively applied to the films of 58 patients who underwent implantation with the CoreValve System (R) between October 2005 and August 2008 and had at least 1-year follow-up. The mean and median follow-up times were 22 months and 24 months, respectively (range 12 to 36 months). Rotational cine films (only left-right lateral) were available in 39 patients (60%). No frame fractures of the CoreValve (R) frame were identified. Conclusions: Rotational cine runs in the left-right and cranial-caudal directions should be mandatory in the clinical assessment of the structural integrity of the CoreValve (R) frame. No frame fractures were identified in 58 patients implanted with the Medtronic CoreValve (R) device with 2-year mean follow-up.
引用
收藏
页码:680 / 686
页数:7
相关论文
共 9 条
[1]   Sirolimus-eluting versus bare nitinol Stent for obstructive superficial femoral artery disease:: The SIROCCO II trial [J].
Duda, SH ;
Bosiers, M ;
Lammer, J ;
Scheinert, D ;
Zeller, T ;
Tielbeek, A ;
Anderson, J ;
Wiesinger, B ;
Tepe, G ;
Lansky, A ;
Mudde, C ;
Tielemans, H ;
Bérégi, JP .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (03) :331-338
[2]   Drug-eluting and bare nitinol stents for the treatment of atherosclerotic lesions in the superficial femoral artery: Long-term results from the SIROCCO trial [J].
Duda, Stephan H. ;
Bosiers, Marc ;
Lammer, Johannes ;
Scheinert, Dierk ;
Zeller, Thomas ;
Oliva, Vincent ;
Tielbeek, Alexander ;
Anderson, John ;
Wiesinger, Benjamin ;
Tepe, Gunnar ;
Lansky, Alexandra ;
Jaff, Michael R. ;
Mudde, Catharina ;
Tielemans, Hans ;
Beregi, Jean-Paul .
JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (06) :701-710
[3]   Fracture of Nitinol under quasistatic and dynamic loading [J].
Jiang, Fengchun ;
Vecchio, Kenneth S. .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2007, 38A (12) :2907-2915
[4]   Longitudinal Stent fracture 11 months after implantation in the left pulmonary artery and successful management by a stent-in-stent maneuver [J].
Knirsch, W ;
Haas, NA ;
Lewin, MAG ;
Uhlemann, F .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (01) :116-118
[5]   Percutaneous pulmonary valve implantation impact of evolving technology and learning curve on clinical outcome [J].
Lurz, Philipp ;
Coats, Louise ;
Khambadkone, Sachin ;
Nordmeyer, Johannes ;
Boudjemline, Younes ;
Schievano, Silvia ;
Muthurangu, Vivek ;
Lee, Twin Yen ;
Parenzan, Giovanni ;
Derrick, Graham ;
Cullen, Seamus ;
Walker, Fiona ;
Tsang, Victor ;
Deanfield, John ;
Taylor, Andrew M. ;
Bonhoeffer, Philipp .
CIRCULATION, 2008, 117 (15) :1964-1972
[6]   Comparison of Bare Metal Stenting and Percutaneous Pulmonary Valve Implantation for Treatment of Right Ventricular Outflow Tract Obstruction Use of an X-Ray/Magnetic Resonance Hybrid Laboratory for Acute Physiological Assessment [J].
Lurz, Philipp ;
Nordmeyer, Johannes ;
Muthurangu, Vivek ;
Khambadkone, Sachin ;
Derrick, Graham ;
Yates, Robert ;
Sury, Michael ;
Bonhoeffer, Philipp ;
Taylor, Andrew M. .
CIRCULATION, 2009, 119 (23) :2995-3001
[7]   Percutaneous pulmonary valve-in-valve implantation: a successful treatment concept for early device failure [J].
Nordmeyer, Johannes ;
Coats, Louise ;
Lurz, Philipp ;
Lee, Twin-Yen ;
Derrick, Graham ;
Rees, Philipp ;
Cullen, Seamus ;
Taylor, Andrew M. ;
Khambadkone, Sachin ;
Bonhoeffer, Philipp .
EUROPEAN HEART JOURNAL, 2008, 29 (06) :810-815
[8]   Fatigue and durability of Nitinol stents [J].
Pelton, A. R. ;
Schroeder, V. ;
Mitchell, M. R. ;
Gong, Xiao-Yan ;
Barney, M. ;
Robertson, S. W. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2008, 1 (02) :153-164
[9]   Prevalence and clinical impact of stent fractures after femoropopliteal stenting [J].
Scheinert, D ;
Scheinert, S ;
Sax, J ;
Piorkowski, C ;
Bräunlich, S ;
Ulrich, M ;
Biamino, G ;
Schmidt, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (02) :312-315