A 25-year study of chordal replacement with expanded polytetrafluoroethylene in mitral valve repair

被引:28
作者
Hata, Hiroki [1 ]
Fujita, Tomoyuki [1 ]
Shimahara, Yusuke [1 ]
Sato, Shunsuke [1 ]
Ishibashi-Ueda, Hatsue [2 ]
Kobayashi, Junjiro [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Surg, Suita, Osaka 5658565, Japan
[2] Natl Cerebral & Cardiovasc Ctr, Dept Pathol, Suita, Osaka 5658565, Japan
关键词
Chordal replacement; Mitral valve repair; Expanded polytetrafluoroethylene; ARTIFICIAL CHORDAE; ANTERIOR; REGURGITATION; TENDINEAE; PROLAPSE; SURGERY; SUTURES; DISEASE;
D O I
10.1093/icvts/ivu441
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: This study examines the outcome of mitral valve repair with chordal replacement using expanded polytetrafluoroethylene over the past 25 years. METHODS: From July 1988 to February 2013, 224 consecutive patients (mean age 57 years, 34% women) underwent mitral valve repair with chordal replacement using expanded polytetrafluoroethylene sutures at our institution. Isolated anterior leaflet prolapse was observed in 134 patients (60%), isolated posterior leaflet prolapse was observed in 13 patients (6%) and bileaflet prolapse was observed in 77 patients (34%). The number of replaced artificial chordae ranged from 2 to 12 (mean 3.7) per patient. Transthoracic echocardiography was performed pre- and postoperatively and in the follow-up period. The follow-up period ranged from 0.3 to 25.3 years (mean 7.4, median 6.2). RESULTS: There was 1 early death and 15 late deaths, of which 7 were cardiac related. The actuarial survival rates at 10 and 20 years were 92 and 81%, respectively. Thirty-three patients (15%) developed recurrent moderate or severe mitral regurgitation during the follow-up period and 30 patients (13%) required reoperation on the mitral valve. Rates of freedom from reoperation and freedom from recurrent moderate or severe mitral regurgitation were 84 and 82% at 10 years, and 74 and 59% at 20 years, respectively. Multivariate analysis revealed that the independent predictors of recurrent mitral regurgitation were mitral valve repair without annuloplasty ring and greater than mild postoperative mitral regurgitation; and the independent predictors of mitral reoperation were previous cardiac surgery and greater than mild postoperative mitral regurgitation. Histopathological analysis of the expanded polytetrafluoroethylene sutures removed during reoperation revealed complete endothelialization without calcification or microthrombi. CONCLUSIONS: Our 25-year follow-up demonstrated reliable long-term outcomes of chordal replacement with expanded polytetrafluoroethylene sutures.
引用
收藏
页码:463 / 468
页数:6
相关论文
共 25 条
[1]  
Amano J, 2013, GEN THORAC CARDIOVAS, V61, P578, DOI 10.1007/s11748-013-0289-2
[2]   Different ways to repair the mitral valve with artificial chordae: a systematic review [J].
Bizzarri, Federico ;
Tudisco, Antonella ;
Ricci, Massimo ;
Rose, David ;
Frati, Giacomo .
JOURNAL OF CARDIOTHORACIC SURGERY, 2010, 5
[3]  
Bortolotti U, 2012, J HEART VALVE DIS, V21, P440
[4]   Mitral Valve Repair With Artificial Chordae: A Review of Its History, Technical Details, Long-Term Results, and Pathology [J].
Bortolotti, Uberto ;
Milano, Aldo D. ;
Frater, Robert W. M. .
ANNALS OF THORACIC SURGERY, 2012, 93 (02) :684-691
[5]  
Braunberger E, 2001, CIRCULATION, V104, pI8
[6]  
CARPENTIER A, 1971, J THORAC CARDIOV SUR, V61, P1
[7]  
CARPENTIER A, 1983, J THORAC CARDIOV SUR, V86, P323
[8]   All anterior and bileaflet mitral valve prolapses are repairable in the modern era of reconstructive surgery [J].
Castillo, Javier G. ;
Anyanwu, Anelechi C. ;
El-Eshmawi, Ahmed ;
Adams, David H. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2014, 45 (01) :139-145
[9]   Long-term results of mitral valve repair for myxomatous disease with and without chordal replacement with expanded polytetrafluoroethylene sutures [J].
David, TE ;
Omran, A ;
Armstrong, S ;
Sun, Z ;
Ivanov, J .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (06) :1279-1285
[10]  
DAVID TE, 1991, J THORAC CARDIOV SUR, V101, P495