Comparison of Physiologic versus Pharmacologic Mydriasis on Anterior Chamber Angle Measurements Using Spectral Domain Optical Coherence Tomography

被引:11
作者
Dastiridou, Anna I. [1 ]
Pan, Xiaojing [1 ,2 ]
Zhang, ZhouYuan [1 ]
Marion, Kenneth M. [1 ]
Francis, Brian A. [1 ,3 ]
Sadda, Srinivas R. [1 ,3 ]
Chopra, Vikas [1 ,3 ]
机构
[1] Doheny Eye Inst, Doheny Image Reading Ctr, Los Angeles, CA 90033 USA
[2] Qingdao Univ, Coll Med, Affiliated Hosp, Qingdao 266003, Shandong, Peoples R China
[3] Univ Calif Los Angeles, David Geffen Sch Med, Dept Ophthalmol, Los Angeles, CA 90095 USA
关键词
CLOSURE GLAUCOMA; DYNAMIC-ANALYSIS; IRIS THICKNESS; PUPIL-DILATION; LIGHT CHANGES; DARK; LINE; PARAMETERS; IRIDOTOMY; BIOMETRY;
D O I
10.1155/2015/845643
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the effects of physiologic versus pharmacologic pupil dilation on anterior chamber angle (ACA) measurements obtained with spectral domain optical coherence tomography (SD-OCT). Methods. Forty eyes from 20 healthy, phakic individuals with open angles underwent anterior segment OCT imaging under 3 pupillary states: (1) pupil constricted under standard room lighting, (2) physiologic mydriasis in a darkened room, and (3) postpharmacologic mydriasis. Inferior angle Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular-iris-space area (SL-TISA) were computed for each eye and pupillary condition by masked, certified Reading Center graders using customized grading software. Results. SL-AOD and SL-TISA under pupillary constriction to room light were 0.87 +/- 0.31 mm and 0.33 +/- 0.14 mm(2), respectively; decreased to 0.75 +/- 0.29 mm (p < 0.01) and 0.29 +/- 0.13 mm(2) (p < 0.01), respectively, under physiologic mydriasis; and increased to 0.90 +/- 0.38 mm ( p < 0.01) and 0.34 +/- 0.17 mm(2) (P = 0.06) under pharmacologic mydriasis compared to baseline. Conclusions. Using SD-OCT imaging, pharmacologic mydriasis yielded the widest angle opening, whereas physiologic mydriasis yielded the most angle narrowing in normal individuals with open iridocorneal angles. Accounting for the state of the pupil and standardizing the lighting condition would appear to be of importance for future studies of the angle.
引用
收藏
页数:6
相关论文
共 31 条
[1]   Biometric Evaluation of Anterior Chamber Changes after Physiologic Pupil Dilation Using Pentacam and Anterior Segment Optical Coherence Tomography [J].
Aptel, Florent ;
Chiquet, Christophe ;
Beccat, Sylvain ;
Denis, Philippe .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) :4005-4010
[2]   Optical Coherence Tomography Quantitative Analysis of Iris Volume Changes after Pharmacologic Mydriasis [J].
Aptel, Florent ;
Denis, Philippe .
OPHTHALMOLOGY, 2010, 117 (01) :c-10
[3]   Determinants of anterior chamber angle narrowing after mydriasis in the patients with cataract [J].
Arimura, Shogo ;
Takamura, Yoshihiro ;
Takihara, Yuji ;
Matsumura, Takehiro ;
Tomomatsu, Takeshi ;
Inatani, Masaru .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (02) :307-312
[4]   Detailed visualization of the anterior segment using Fourier-domain optical coherence tomography [J].
Asrani, Sanjay ;
Sarunic, Marinko ;
Santiago, Cecilia ;
Izatt, Joseph .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (06) :765-771
[5]   Novel anterior-chamber angle measurements by high-definition optical coherence tomography using the Schwalbe line as the landmark [J].
Cheung, Carol Y. ;
Zheng, Ce ;
Ho, Ching-Lin ;
Tun, Tin A. ;
Kumar, Rajesh S. ;
El Sayyad, Fouad ;
Wong, Tien Y. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (07) :955-959
[6]   Dynamic Analysis of Iris Configuration with Anterior Segment Optical Coherence Tomography [J].
Cheung, Carol Yim-lui ;
Liu, Shu ;
Weinreb, Robert N. ;
Liu, Jing ;
Li, Haitao ;
Leung, Dexter Yu-lung ;
Dorairaj, Syril ;
Liebmann, Jeffrey ;
Ritch, Robert ;
Lam, Dennis Shun Chiu ;
Leung, Christopher Kai-shun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) :4040-4046
[7]   Biometry and primary angle-closure glaucoma among Chinese, white, and black populations [J].
Congdon, NG ;
Qi, YL ;
Quigley, H ;
Hung, PT ;
Wang, TH ;
Ho, TC ;
Tielsch, JM .
OPHTHALMOLOGY, 1997, 104 (09) :1489-1495
[8]   Ocular biometry in occludable angles and angle closure glaucoma: a population based survey [J].
George, R ;
Paul, PG ;
Baskaran, M ;
Ramesh, SV ;
Raju, P ;
Arvind, H ;
McCarty, C ;
Vijaya, L .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (04) :399-402
[9]   Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles [J].
Hirose, Fumitaka ;
Hata, Masayuki ;
Ito, Shin-ichiro ;
Matsuki, Takaaki ;
Kurimoto, Yasuo .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (10) :2395-2402
[10]   Association between Baseline Iris Thickness and Prophylactic Laser Peripheral Iridotomy Outcomes in Primary Angle-Closure Suspects [J].
Lee, Roland Y. ;
Kasuga, Toshimitsu ;
Cui, Qi N. ;
Porco, Travis C. ;
Huang, Guofu ;
He, Mingguang ;
Lin, Shan C. .
OPHTHALMOLOGY, 2014, 121 (06) :1194-1202