Symptoms, complaints, ocular and nasal physiological signs in university staff in relation to indoor environment -: temperature and gender interactions

被引:26
作者
Bakke, J. V. [1 ]
Norback, D. [2 ,6 ]
Wieslander, G. [2 ,6 ]
Hollund, B. -E. [1 ]
Florvaag, E. [3 ,4 ]
Haugen, E. N. [5 ]
Moen, B. E. [1 ]
机构
[1] Univ Bergen, Dept Publ Hlth & Primary Care, Sect Occupat Med, N-5018 Bergen, Norway
[2] Uppsala Univ, Dept Med Sci Occupat & Environm Med, Uppsala, Sweden
[3] Haukeland Hosp, Lab Clin Biochem, N-5021 Bergen, Norway
[4] Univ Bergen, Inst Internal Med, Bergen, Norway
[5] SINTEF Energy Res AS, Trondheim, Norway
[6] Univ Uppsala Hosp, Dept Med Sci Occupat & Environm Med, Uppsala, Sweden
关键词
indoor air quality; thermal climate; thermal comfort; tear film; nasal patency; building-related perceptions;
D O I
10.1111/j.1600-0668.2007.00515.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Symptoms, signs, perceptions, and objective measures were studied in university buildings. Two problem buildings with a history of dampness and complaints were compared with two control buildings. Health investigations among university staff were performed at the workplace (n = 173) including tear film stability [non-invasive break-up time (NIBUT) and self-reported break-up time (SBUT)], nasal patency (acoustic rhinometry), nasal lavage fluid analysis [NAL: eosinophil cationic protein (ECP), myeloperoxidase (MPO), lysozyme and albumin] and atopy by total serum IgE and IgE antibodies (Phadiatop (R)). Exposure assessment included inspections, thermal and atmospheric climate at 56 points modelled for all work sites. Multiple regressions were applied, controlling for age and gender. Exposure differences between problem buildings and controls were small, and variations between rooms were greater. Workers in the problem buildings had more general and dermal symptoms, but not more objective signs than the others. Adjusted day NIBUT and SBUT increased at higher night air temperatures, with B (95% CI) 0.6 (0.04-1.2) and 1.3 (-0.02 to 2.5), respectively. Higher relative humidity at mean day air temperature < 22.1 degrees C was associated with adjusted NIBUT and SBUT, with B (95% CI) 0.16 (0.03-0.29) and 0.37 (-0.01 to 0.75), respectively. Air velocity below recommended winter values and reduced relative humidity in the range of 15-30% were associated with dry air and too low temperature.
引用
收藏
页码:131 / 143
页数:13
相关论文
共 56 条
[51]   Changes of symptoms, tear film stability and eosinophilic cationic protein in nasal lavage fluid after re-exposure to a damp office building with a history of flooding [J].
Wieslander, G. ;
Norback, D. ;
Venge, P. .
INDOOR AIR, 2007, 17 (01) :19-27
[52]   The modern office environment desiccates the eyes? [J].
Wolkoff, P. ;
Nojgaard, J. K. ;
Franck, C. ;
Skov, P. .
INDOOR AIR, 2006, 16 (04) :258-265
[53]   Are we measuring the relevant indoor pollutants? [J].
Wolkoff, P ;
Clausen, PA ;
Jensen, B ;
Nielsen, GD ;
Wilkins, CK .
INDOOR AIR, 1997, 7 (02) :92-106
[54]  
World Health Organization, 1999, STRAT APPR IND AIR P
[55]   The effects of indoor air quality on performance and productivity [J].
Wyon, DP .
INDOOR AIR, 2004, 14 :92-101
[56]  
WYON NM, 1987, ACTA OPHTHALMOL, V65, P385