Low-cost PM2.5 Sensors: An Assessment of their Suitability for Various Applications

被引:59
作者
Jayaratne, Rohan [1 ]
Liu, Xiaoting [1 ]
Ahn, Kang-Ho [2 ]
Asumadu-Sakyi, Akwasi [1 ]
Fisher, Gavin [3 ]
Gao, Jian [4 ]
Mabon, Adrian [1 ,8 ]
Mazaheri, Mandana [1 ,9 ]
Mullins, Benjamin [6 ]
Nyaku, Mawutorli [1 ]
Ristovski, Zoran [1 ]
Scorgie, Yvonne [5 ]
Phong Thai [1 ,10 ]
Dunbabin, Matthew [7 ]
Morawska, Lidia [1 ]
机构
[1] Queensland Univ Technol, Int Lab Air Qual & Hlth, Brisbane, Qld 4001, Australia
[2] Hanyang Univ, Seoul 04763, South Korea
[3] Environm Protect Author, Carlton, Vic, Australia
[4] Chinese Res Inst Environm Sci, Beijing 100012, Peoples R China
[5] NSW Off Environm & Heritage, Sydney, NSW, Australia
[6] Curtin Univ, Sch Publ Hlth, Perth, WA, Australia
[7] Queensland Univ Technol, Inst Future Environm, Brisbane, Qld, Australia
[8] Ecole Mines Albi Carmaux, Albi, France
[9] NSW Dept Planning & Environm, Sydney, NSW, Australia
[10] Univ Queensland, Queensland Alliance Environm Hlth Sci, Brisbane, Qld, Australia
基金
澳大利亚研究理事会;
关键词
Low-cost sensors; PM sensors; Atmospheric aerosols; Air pollution; PARTICULATE MATTER SENSORS; AIR-QUALITY; LABORATORY EVALUATION; FIELD-EVALUATION; PERFORMANCE; PARTICLE; MONITORS; NETWORK; CALIBRATION; EMISSIONS;
D O I
10.4209/aaqr.2018.10.0390
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recently, there has been a substantial increase in the availability and use of low-cost particulate matter sensors in a wide range of air quality applications. They carry the promise of revolutionising air quality monitoring, yet considerable reservations exist regarding their performance and capabilities, thus hindering the broader-scale utilization of these devices. In order to address these concerns and assess their feasibility and accuracy for various applications, we evaluated six low-cost PM2.5 sensors (the Sharp GP2Y1010AU0F, Shinyei PPD42NS, Plantower PMS1003, Innociple PSM305, Nova SDS011 and Nova SDL607) in laboratory and field conditions using two combustion aerosols, concrete dust and ambient particles. In assessing the performance of these sensors, we focussed on indicators such as the linearity, accuracy and precision, critically differentiating between these qualities, and employed inter-comparison (the coefficient of determination, R-2). In the laboratory, all sensors responded well, with an R-2 > 0.91 when the PM2.5 concentration was > 50 mu g m(-3), as measured by the DustTrak. In particular, the PMS1003 demonstrated good accuracy and precision in both laboratory and ambient conditions. However, some limitations were noted for the tested sensors at lower concentrations. For example, the Sharp and Shinyei sensors showed poor correlations (R-2 < 0.1) with the DustTrak when the ambient PM2.5 concentration was < 20 mu g m(-3). These results suggest that the sensors should be calibrated individually for each source in the environment of their intended use. We demonstrate that when tested appropriately and used with a full understanding of their capabilities and limitations, low-cost sensors can serve as an unprecedented aid in a broad spectrum of air quality applications, including the emerging field of citizen science.
引用
收藏
页码:520 / 532
页数:13
相关论文
共 36 条
  • [1] Laboratory Evaluation of the Shinyei PPD42NS Low-Cost Particulate Matter Sensor
    Austin, Elena
    Novosselov, Igor
    Seto, Edmund
    Yost, Michael G.
    [J]. PLOS ONE, 2015, 10 (09):
  • [2] Canu M, 2018, 2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENTAL ENGINEERING (EE)
  • [3] Can commercial low-cost sensor platforms contribute to air quality monitoring and exposure estimates?
    Castell, Nuria
    Dauge, Franck R.
    Schneider, Philipp
    Vogt, Matthias
    Lerner, Uri
    Fishbain, Barak
    Broday, David
    Bartonova, Alena
    [J]. ENVIRONMENT INTERNATIONAL, 2017, 99 : 293 - 302
  • [4] Development of Low-Cost Air Quality Stations for Next Generation Monitoring Networks: Calibration and Validation of PM2.5 and PM10 Sensors
    Cavaliere, Alice
    Carotenuto, Federico
    Di Gennaro, Filippo
    Gioli, Beniamino
    Gualtieri, Giovanni
    Martelli, Francesca
    Matese, Alessandro
    Toscano, Piero
    Vagnoli, Carolina
    Zaldei, Alessandro
    [J]. SENSORS, 2018, 18 (09)
  • [5] Performance of low-cost monitors to assess household air pollution
    Curto, A.
    Donaire-Gonzalez, D.
    Barrera-Gomez, J.
    Marshall, J. D.
    Nieuwenhuijsen, M. J.
    Wellenius, G. A.
    Tonne, C.
    [J]. ENVIRONMENTAL RESEARCH, 2018, 163 : 53 - 63
  • [6] A distributed network of low-cost continuous reading sensors to measure spatiotemporal variations of PM2.5 in Xi'an, China
    Gao, Meiling
    Cao, Junji
    Seto, Edmund
    [J]. ENVIRONMENTAL POLLUTION, 2015, 199 : 56 - 65
  • [7] Impact of California Fires on Local and Regional Air Quality: The Role of a Low-Cost Sensor Network and Satellite Observations
    Gupta, P.
    Doraiswamy, P.
    Levy, R.
    Pikelnaya, O.
    Maibach, J.
    Feenstra, B.
    Polidori, Andrea
    Kiros, F.
    Mills, K. C.
    [J]. GEOHEALTH, 2018, 2 (06): : 172 - 181
  • [8] Aerosol Chamber Characterization for Commercial Particulate Matter (PM) Sensor Evaluation
    Hapidin, Dian Ahmad
    Saputra, Casmika
    Maulana, Dian Syah
    Munir, Muhammad Miftahul
    Khairurrijal, Khairurrijal
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2019, 19 (01) : 181 - 194
  • [9] Intercomparison of five PM10 monitoring devices and the implications for exposure measurement in epidemiological research
    Heal, MR
    Beverland, IJ
    McCabe, M
    Hepburn, W
    Agius, RM
    [J]. JOURNAL OF ENVIRONMENTAL MONITORING, 2000, 2 (05): : 455 - 461
  • [10] Performance evaluation of three optical particle counters with an efficient "multimodal" calibration method
    Heim, Michael
    Mullins, Benjamin J.
    Umhauer, Heinz
    Kasper, Gerhard
    [J]. JOURNAL OF AEROSOL SCIENCE, 2008, 39 (12) : 1019 - 1031