A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants

被引:38
作者
Bougherara, Habiba [2 ]
Zdero, Rad [1 ,2 ]
Dubov, Anton [2 ]
Shah, Suraj [1 ,2 ]
Khurshid, Shaheen [2 ]
Schemitsch, Emil H. [1 ,3 ]
机构
[1] St Michaels Hosp, Martin Orthopaed Biomech Lab, Toronto, ON M5B 1W8, Canada
[2] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
[3] Univ Toronto, Dept Surg, Toronto, ON M5G 1L5, Canada
关键词
Biomechanics; Finite element; Hip stem; Carbon-fibre polyamide 12; Exeter; Omnifit Eon; FINITE-ELEMENT-ANALYSIS; FORCES; FEMURS; MUSCLE;
D O I
10.1016/j.medengphy.2010.09.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total hip arthroplasty is a widespread surgical approach for treating severe osteoarthritis of the human hip. Aseptic loosening of standard metallic hip implants due to stress shielding and bone loss has motivated the development of new materials for hip prostheses. Numerically, a three-dimensional finite element (FE) model that mimicked hip implants was used to compare a new hip stem to two commercially available implants. The hip implants simulated were a novel CF/PA12 carbon-fibre polyamide-based composite hip stem, the Exeter hip stem (Stryker, Mahwah, NJ, USA), and the Omnifit Eon (Stryker, Mahwah, NJ, USA). A virtual axial load of 3 kN was applied to the FE model. Strain and stress distributions were computed. Experimentally, the three hip stems had their distal portions rigidly mounted and had strain gauges placed along the surface at 3 medial and 3 lateral locations. Axial loads of 3 kN were applied. Measurements of axial stiffness and strain were taken and compared to FE analysis. The overall linear correlation between FE model versus experimental strains showed reasonable results for the lines-of-best-fit for the Composite (Pearson R-2 = 0.69, slope = 0.82), Exeter (Pearson R-2 = 0.78, slope = 0.59), and Omnifit (Pearson R-2 = 0.66, slope = 0.45), with some divergence for the most distal strain locations. From FE analysis, the von Mises stress range for the Composite stem was much lower than that in the Omnifit and Exeter implants by 200% and 45%, respectively. The preliminary experiments showed that the Composite stem stiffness (1982 N/mm) was lower than the metallic hip stem stiffnesses (Exeter, 2460 N/mm; Omnifit, 2543 N/mm). This is the first assessment of stress, strain, and stiffness of the CF/PA12 carbon-fibre hip stem compared to standard commercially-available devices. (C) 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 41 条
[1]  
Akay M, 1996, J BIOMED MATER RES, V31, P167
[2]  
*ANSYS, ANSYS ONL MOD GUID
[3]  
BANIA PJ, 1984, TITANIUM ALLOYS 1980, P209
[4]  
BARGAR WL, 1991, HIP ITS DISORDERS, P1125
[5]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[6]   The biomechanics of the T2 femoral nailing system: a comparison of synthetic femurs with finite element analysis [J].
Bougherara, H. ;
Zdero, R. ;
Miric, M. ;
Shah, S. ;
Hardisty, M. ;
Zalzal, P. ;
Schemitsch, E. H. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H3) :303-314
[7]  
BOUGHERARA H, 2009, J BIOMED MAT RES A
[8]   Design of a biomimetic polymer-composite hip prosthesis [J].
Bougherara, Habiba ;
Bureau, Martin ;
Campbell, Melissa ;
Vadean, Aurelian ;
Yahia, L'Hocine .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) :27-40
[9]   A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements [J].
Bougherara, Habiba ;
Zdero, Rad ;
Shah, Suraj ;
Miric, Milan ;
Papini, Marcello ;
Zalzal, Paul ;
Schemitsch, Emil H. .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
[10]  
BUREAU MN, 2006, P 52 ANN M ORTH RES