Disposable Miniaturized Screen-Printed pH and Reference Electrodes for Potentiometric Systems

被引:16
作者
Musa, Arnaud Emmanuel [2 ]
Javier del Campo, Francisco [1 ]
Abramova, Natalia [1 ]
Asuncion Alonso-Lomillo, Maria [3 ]
Dominguez-Renedo, Olga [3 ]
Julia Arcos-Martinez, Maria [3 ]
Brivio, Monica [2 ]
Snakenborg, Detlef [2 ]
Geschke, Oliver [2 ]
Kutter, Jorg Peter [2 ]
机构
[1] IMB CNM CSIC, Inst Microelect Barcelona, Esfera UAB, Barcelona 08193, Spain
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, DTU Nanotech, DK-2800 Lyngby, Denmark
[3] Univ Burgos, Fac Ciencias, Dept Quim Analit, Burgos 09001, Spain
关键词
Screen-printed-electrode (SPE); Potentiometry; pH-electrode; ION-SELECTIVE ELECTRODE; SOLID-CONTACT; SENSORS; PLASTICIZER; MEMBRANES; POLYMERS; SODIUM; ARRAYS;
D O I
10.1002/elan.201000443
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work describes the development of a miniaturized potentiometric system comprising a miniaturized quasi-reference electrode (QRE) coupled to a solid-state ion-selective electrode (ISE) for the monitoring of pH. We describe the optimization of materials and fabrication processes including screen-printing (SP), electrode treatments (thermal and electrochemical) and the formulation and deposition of an ion-selective membrane (ISM), to obtain a system compliant with biomedical specifications. We developed a potentiometric system composed of an Ag/AgCl QRE and a pH-electrode (ISM deposited on a graphite electrode) that can be used continuously for a period of not less than 7 days in aqueous solutions. Curing the Ag/AgCl pastes during 20 minutes at 120 degrees C after printing allowed the QREs to display excellent potential stability, as demonstrated by an open-circuit-potential standard deviation of +/- 1.2 mV over a period of 7 days (n = 3 samples). Promoting adhesion of the pH membrane over graphite electrodes improved the pH-electrode performance. This was achieved through a combination of thermal treatment and electrochemical activation of the electrodes by cyclic voltammetry (CV). The final device integrated both the QRE and the pH-electrode, and displayed an average pH sensitivity of -60.8 +/- 1.7 mV per pH unit, over a pH range of 7.00 to 7.63.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 32 条
  • [1] Photocurable pH-sensitive membrane for ion-selective field effect transistors
    Abramova, Natalia
    Bratov, Andrey
    [J]. TALANTA, 2010, 81 (1-2) : 208 - 212
  • [2] Photocurable Polymers for Ion Selective Field Effect Transistors. 20 Years of Applications
    Abramova, Natalia
    Bratov, Andrei
    [J]. SENSORS, 2009, 9 (09) : 7097 - 7110
  • [3] Integrated multi-sensor chip with photocured polymer membranes containing copolymerised plasticizer for direct pH, potassium, sodium and chloride ions determination in blood serum
    Abramova, Natalia
    Ipatov, Andrey
    Levichev, Sergey
    Bratov, Andrey
    [J]. TALANTA, 2009, 79 (04) : 984 - 989
  • [4] Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers
    Bobacka, J
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (21) : 4932 - 4937
  • [5] Burtis C. A., 2001, FUNDAMENTALS CLIN CH, P105
  • [6] ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS
    CHA, GS
    LIU, D
    MEYERHOFF, ME
    CANTOR, HC
    MIDGLEY, AR
    GOLDBERG, HD
    BROWN, RB
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1666 - 1672
  • [7] ION-SELECTIVE MICROCHEMICAL SENSORS WITH REDUCED PRECONDITIONING TIME - MEMBRANE BIOSTABILITY STUDIES AND APPLICATIONS IN BLOOD ANALYSIS
    COSOFRET, VV
    ERDOSY, M
    LINDNER, E
    JOHNSON, TA
    BUCK, RP
    KAO, WJ
    NEUMAN, MR
    ANDERSON, JM
    [J]. ANALYTICAL LETTERS, 1994, 27 (15) : 3039 - 3063
  • [8] Effect of pre-treatment on the surface and electrochemical properties of screen-printed carbon paste electrodes
    Cui, G
    Yoo, JH
    Lee, JS
    Yoo, J
    Uhm, JH
    Cha, GS
    Nam, H
    [J]. ANALYST, 2001, 126 (08) : 1399 - 1403
  • [9] Recent developments in the field of screen-printed electrodes and their related applications
    Dominguez Renedo, O.
    Alonso-Lomillo, M. A.
    Arcos Martinez, M. J.
    [J]. TALANTA, 2007, 73 (02) : 202 - 219
  • [10] Fibbioli M., 2000, ELECTROANAL, P12