Two-step method for identification of nonlinear model of induction machine

被引:15
作者
Wamkeue, Rene [1 ]
Aguglia, Davide
Lakehal, Mustapha
Viarouge, P.
机构
[1] Univ Quebec, Rouyn Noranda, PQ J9X 5E4, Canada
[2] Univ Laval, Quebec City, PQ G1K 7P4, Canada
[3] Univ Appl W Switcherland, Hautes Ecole Special Suisse Occidentale, CH-1705 Fribourg, Switzerland
关键词
cross saturation; cross validation; identification; induction machine (IM);
D O I
10.1109/TEC.2006.888044
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A two-step method is applied for parameter identification of a saturated electromechanical model of an induction machine (IM). The k-factor cross saturation technique is used to account for iron saturation. Balanced and unbalanced short-circuits armature current waveforms of this machine are less sensitive to variations in the mechanical parameters. Conversely, any change in these parameters has a strong impact on the start-up test. Accordingly, in the proposed estimation method, the online double-line-to-neutral short-circuit test is performed to estimate the electrical parameters of the machine and the results obtained are then used to compute the mechanical parameters from the starting test. The good agreement of the estimated results with actual data attests to the effectiveness and suitability of the proposed algorithm in computing the electromechanical parameters of these machines.
引用
收藏
页码:801 / 809
页数:9
相关论文
共 26 条
[1]   CASE-STUDY ON THE INTEGRATION OF A NONUTILITY INDUCTION GENERATOR TO THE HYDRO-QUEBEC DISTRIBUTION NETWORK [J].
BELHOMME, R ;
PLAMONDON, M ;
NAKRA, H ;
DESROSIERS, D ;
GAGNON, C .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (03) :1677-1684
[2]  
Boldea I, 2002, ELECTR POWER ENGN SE, pNIL_3
[3]  
CHAPMAN SJ, 2005, ELECTRI MACHINERY FU
[4]   DETERMINATION OF THE PARAMETERS REPRESENTING THE CROSS-MAGNETIZING EFFECT IN SATURATED SYNCHRONOUS MACHINES [J].
ELSERAFI, AM ;
WU, J ;
DANDENO, PL .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1993, 8 (03) :333-342
[5]  
ERDOGAN N, P EL 2003 C, P175
[6]  
Jenkins N, 2000, EMBEDDED GENERATION
[7]   Identification of physical parameters of a synchronous generator from online measurements [J].
Karrari, M ;
Malik, OP .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (02) :407-415
[8]   Parameter identification of induction motors using dynamic encoding algorithm for searches (DEAS) [J].
Kim, JW ;
Kim, SW .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (01) :16-24
[9]  
KRAUSE PC, 1995, ANAL ELECTRIC MACHIN
[10]   Online parameter estimation of round rotor synchronous generators including magnetic saturation [J].
Kyriakides, E ;
Heydt, GT ;
Vittal, V .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (03) :529-537